Whirlpool AKM 252/WH, KGN 5382 A2 FRESH PT, AKM 252/BR INSTRUCTION FOR USE

AKM 252

GB

IE

PRODUCT DESCRIPTION SHEET

1. Removable panstand grids

2-3. Medium burners

4. Large burner

5. Auxiliary burner

6. Medium burner control knob

7. Medium burner control knob

8. Large burner control knob

9. Auxiliary burner control knob

10. Timer control knob

Symbols

Shaded

Valve closed

circle

 

High flame

Maximum aperture/supply

and star

and electric ignition

Low flame

Minimum aperture/supply

Electrically ignited gas burner user instructions

How to ignite one of the burners:

Push and turn the corresponding knob anti-

clockwise until the reference is aligned with the high flame and star symbols .

At the same time hold the knob against the control panel until the burner ignites.

Let go of the knob.

If the burner fails to ignite, repeat the sequence.

Note:

-If problems with local gas supply impede burner

ignition, repeat the sequence by turning the knob to the low flame symbol .

Glass cover with safety valve

The cover is equipped with a safety valve which shuts off the supply of gas when the cover is closed. However, if the burner is not turned off when the cover is closed, gas will escape from the burner when the cover is reopened.

Make sure all the knobs are switched off before closing the cover.

Using the timer

This particular model features a mechanical timer which can time up to one hour of cooking.

Turn the knob clockwise until the reference is aligned with the desired cooking time.

When the set time elapses an acoustic signal is activated.

5019 319 61321

Whirlpool AKM 252/WH, KGN 5382 A2 FRESH PT, AKM 252/BR INSTRUCTION FOR USE

DIMENSIONS OF COOKING HOB AND WORKTOP

NOTES: In case of installation of a hood above the cooktop, please refer to the hood

instructions for the correct distance.

 

 

 

 

 

 

 

 

 

 

INJECTORS TABLE

 

 

 

 

 

 

 

 

 

 

 

CATEGORY II2H3+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type of gas

 

 

Type of

Injector

Rated heat

Rated

 

Reduced

 

Gas pressure

used

 

 

burner

marking

capacity

consumption

 

heat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

capacity

min.

 

rat.

max.

 

 

 

 

 

 

 

Pcs-kW

 

 

 

 

Pcs-kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NATURAL GAS

 

 

large

128

 

3.00

 

286 l/h

 

0.60

 

 

 

 

 

 

 

medium

94

 

1.65

 

157 l/h

 

0.35

17

 

20

25

(Methane)

G 20

 

 

 

 

 

 

small

76

 

1.00

 

95 l/h

 

0.30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LIQUIFIED

 

 

large

85

 

3.00

218 g/h

 

0.60

 

 

 

 

 

PETROLEUM GAS

 

medium

65

 

1.65

120 g/h

 

0.35

20

 

28-30

35

(Cylinder)

G 30

 

small

50

 

1.00

 

73 g/h

 

0.30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LIQUIFIED

 

 

large

85

 

3.00

214 g/h

 

0.60

 

 

 

 

 

PETROLEUM GAS

 

medium

65

 

1.65

118 g/h

 

0.35

25

 

37

45

(Cylinder)

G 31

 

small

50

 

1.00

 

71 g/h

 

0.30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type of gas

 

 

 

Appliance

 

 

Total rated heat

 

Total rated

 

Air required

 

used

 

 

 

model

 

 

capacity

 

 

consumption

 

for burning

 

 

 

 

 

 

 

 

Pcs-kW

 

 

 

 

 

 

m3/h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G 20 20 mbar

 

 

 

4 gas

 

 

7.30

 

 

695 l/h

 

 

14.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G 30 28-30 mbar

 

4 gas

 

 

7.30

 

 

531 g/h

 

 

14.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G 31 37 mbar

 

 

 

4 gas

 

 

7.30

 

 

521 g/h

 

 

14.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Loading...