Whirlpool AKM 250/IX Service Manual

SERVICE
Model AKM 250/IX Version 8571 250 10000 Page
Whirlpool Europe Customer Services
AKM 250/IX
Service Manual
Gas hob AKM 250/IX
Technical data 2
Spare part list 3
Exploded view 4
Wiring diagram 5
This documentation is only intended for qualified technicians who are aware of the respec­tive safety regulations. Date: 12.08.1997 Subject to modification Document-No.: 4812 715 16752
12.08.1997 / Page 2 AKM 250/IX Whirlpool Europe Doc. No: 4812 715 16752 8571 250 10000 Customer Service
Technical data
SERVICE
Type of gas used Type of
burner
Natural Gas (Methane) G 20
Natural Gas (Cylinder) G 30
Natural Gas (Cylinder) G 31
large
medium
small
large
medium
small
large
medium
small
Injector
marking
128
94 79
85 65 50
85 65 50
Rated heat
capacity PCS-kW
3,00 1,65 1,00
3,00 1,65 1,00
3,00 1,65 1,00
Rated
consumption
286 l/h 157 l/h
95 l/h
218 g/h 120 g/h
73 g/h
214 g/h 118 g/h
71 g/h
1. Medium Burner
2. Medium Burner
3. Large Burner
4. Small Burner
Voltage: 230 V Frequency: 50 Hz
Reducedheat
capacity PCS-kW
0,60 0,35 0,30
0,60 0,25 0,30
0,60 0,25 0,30
Gas pressure (mbar)
min. rat. max.
17 20 25
20 28-30 35
25 37 45
Type of gas used Appliance
model
G20 20 mbar 4G 7,30 695 l/h 14,6
G30 28-30 mbar 4G 7,30 531 g/h 14,6
G31 37 mbar 4G 7,30 521 g/h 14,6
Total rated heat
capacity PCS-kW
Total rated
consumption
Air required for
burning m/h
Loading...