Whirlpool AKM 224 NB INSTRUCTION FOR USE

AKM 224 PRODUCT DESCRIPTION SHEET
CZ SK
1.
Removable panstand grids
2-3.
Medium burners
4.
Large burner
5.
Small burner
Symbols
Shaded circle Tap closed
Large flame Maximum opening/delivery
The control knobs of the cooking hob
burners and the electric ignition push-
button are on the control panel of the oven.
Operation of burners
Press the relative knob and turn it
anti-clockwise to the large flame setting
At the same time, press the push-button with
a star .
The spark plug gives out a spark that causes
the burner to ignite.
If the burner does not ignite, press the
push-button again.
.
Small flame
Star
Minimum opening
or reduced delivery
Electric ignition
push-button
Note:
-
Should particular local conditions of the
delivered gas make the ignition of the burner
difficult, it is advisable to repeat the operation
with the knob turned to the small flame
setting .
Important
Improper use of the grids can result in damage to
the hob: do not position the grids upside down or
slide them across the hob.
Do not use:
-
cast iron griddles or terracotta pots and pans
-
heat diffusers such as metal mesh, or any other
types
-
two burners simultaneously for one receptacle
(e.g. fish kettle).
5019 319 54051
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
r
NOTE: In case of installation of a hood above the cooktop, please refer to the hood instructions fo
the correct distance.
INJECTORS TABLE CATEGORY II2H3+
Type of gas
used
NATURAL GAS
(Methane) G20
LIQUID PETROLEUM
GAS
(Cylinder) G30
LIQUID PETROLEUM
GAS
(Cylinder) G31
Type of gas used
G20 20 mbar 4 gas 7.30 695 l/h 14.6
G30 28-30 mbar 4 gas 7.30 531 g/h 14.6
G31 37 mbar 4 gas 7.30 521 g/h 14.6
Type of
burner
large
medium
small
large
medium
small
large
medium
small
Appliance
model
Injector
marking
100/mm
128
94
76
85
65
50
85
65
50
Rated heat
capacity
kW
3.00
1.65
1.00
3.00
1.65
1.00
3.00
1.65
1.00
Total rated heat
capacity
kW
Rated
consumption
286 l/h
157 l/h
95 l/h
218 g/h
120 g/h
73 g/h
214 g/h
118 g/h
71 g/h
Reduced
heat
capacity
kW
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
Total rated
consumption
ELECTRIC SUPPLY: 230 V - 50 Hz
Gas pressure mbar
min. rat. max.
17 20 25
20 28-30 35
25 37 45
Air required
for burning
3
m
/h
Loading...