INSTALLATION
Technical information for the installer
OVEN
•
After removing the oven from its packaging,
before making the connections place it on the
polystyrene foam base to protect it from
damage.
•
Do not attempt to lift the oven by the handle.
Lift at the sides as shown in the figure (see
Arrow).
•
Check that the appliance has not been
damaged in transit.
•
Oven dimensions and kitchen unit dimensions
are shown in the opposite figure.
•
Kitchen units in contact with the oven must be
heat resistant (80° C).
•
If plastic laminates or cement are not
sufficiently heat-resistant, warping, bubbling
or detachment of the finish may result.
•
Connect the earth wire (A) of the cooktop to
the oven (B)as illustrated.
•
Connect clamps (C) of the cooktop to the oven
junction block (D) situated in the upper
section, following the colour code indicated on
the plate.
•
For correct ventilation, follow the ventilation
opening directions shown in the figure (at least
500 x 80 mm). Also provide for at least 5 mm
clearance between the top of the oven and the
lower edge of the worktop.
This space must not be obstructed by cross
rails or other structural elements.
•
During oven installation, care must be taken to
ensure that the sides are not touching the front
edges of the housing or adjacent drawers and
doors (see picture).
•
Carry out the electrical connections between
cooktop and oven (see chapterElectrical
Connections”).
•
Secure the oven to the kitchen unit with
screws (A) as shown.
No contacts
67
ELECTRICAL CONNECTIONS
• Make sure the appliances are installed and
connected to the electricity supply by a
qualified technician in accordance with
the manufacturer’s instructions and in
compliance with local regulations.
• The installer is responsible for the correct
electrical connection of the appliances and
the observance of the relative safety
prescriptions.
• The oven must be connected to the
electricity supply by means of an all-pole
disconnect switch with minimum contact
gap of 3 mm.
Connecting the oven to the power supply
Make sure that the voltage shown on the rating
•
plate is the same as the power supply voltage
in your home. The rating plate is on the front
edge of the oven cavity (visible with oven door
open).
Use a type H05RR-F power cord (minimum
•
length 800 mm).
• Attention: All the oven’s components
operate at 230-240 V. When using a 400 V
connection, make sure that the voltage
reaching the oven is 230-240 V, as
illustrated in the side table.
• The appliances must be earthed by law.
• Do not use multiple plug adapters or
extension leads.
• After the oven has been installed,
the electrical components must be
inaccessible.
Conductors X
number
1N +
2N +
3+
3N +
68
Connection
~
~
~
~
H05 RR-F 3x4 mm²
H05 RR-F 4x2,5 mm²
H05 RR-F 4x2,5 mm²
H05 RR-F 5x1,5 mm²