Whirlpool AKL 710/NA, AKL 710/NB, AKL 710/TF, AKL 710/JA, AKL 710/AE INSTRUCTION FOR USE

...
AKL 710 PRODUCT DESCRIPTION SHEET
IT
Removable panstand grids
1.
Medium burners
2-3.
Large burner
4.
Small burner
5.
Medium burner control knob
6.
Medium burner control knob
7.
Large burner control knob
8.
Small burner control knob
9.
Electric ignition button
10.
Symbols
Operation of burners with safety device and electric ignition
To light one of the burners:
Press the relative knob and turn it anti­clockwise to the large flame setting .
Once the burner is lit, keep the knob pressed for about 10 seconds.
Release the knob.
If the burner does not ignite, repeat the operation.
5019 519 60001
Shaded circle
Large flame Maximum open ing/delivery
Small flame
Tap closed
Minimum opening or reduced delivery
Note:
Should particular local conditions of the
-
delivered gas make the ignition of the burner difficult, it is advisable to repeat the operation with the knob turned to the small flame setting .
The burner safety system serves to prevent
-
the emission of gas if the flame should be extinguished accidentally (draughts, interruptions in gas supply, dousing with liquids, etc.).
DIMENSIONS OF COOKING HOB AND WORKTOP
NOTES: In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
INJECTORS TABLE CATEGORY II2H3+
Type of gas used Type of
NATURAL GAS (Methane) G 20
LIQUID PETROLEUM GAS
(Cylinder) G 30 LIQUID
PETROLEUM GAS (Cylinder) G 31
Type of gas used Appliance model Total rated heat
G 20 20 mbar 4 gas 7.30 695 l/h 14.6 G 30 28-30 mbar 4 gas 7.30 531 g/h 14.6 G 31 37 mbar 4 gas 7.30 521 g/h 14.6
burner
large medium small
large medium small
large medium small
Injector marking
128
94 76
85 65 50
85 65 50
Rated heat capacity Pcs-kW
3.00
1.65
1.00
3.00
1.65
1.00
3.00
1.65
1.00
capacity Pcs-kW
Rated consumption
286 l/h 157 l/h
95 l/h
218 g/h 120 g/h
73 g/h
214 g/h 118 g/h
71 g/h
Total rated consumption
Reduced heat capacity Pcs-kW
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
min. rat. max.
17 20 25
20 28-30 35
25 37 45
Air required for burning m
Gas pressure
3
/h
Loading...