5gb61051.fm5 Page 1 Friday, September 14, 2001 10:43 AM
AKL 704 |
NL |
PRODUCT DESCRIPTION SHEET |
1. Removable panstand grids
2-3. Medium burners
4. Large burner
5. Small burner
6. Medium burner control knob
7. Medium burner control knob
8. Large burner control knob
9. Small burner control knob
Symbols
Shaded
Tap closed
circle
Large flame
Maximum opening/ delivery
Small flame
Minimum opening or reduced delivery
Operation of burners with electric ignition
To light one of the burners:
•Press the relative knob and turn it anticlockwise to the large flame setting .
•At the same time, approach a flame to the relative burner until it ignites.
If the burner does not ignite, repeat the operation.
5019 519 61051
5gb61051.fm5 Page 2 Friday, September 14, 2001 10:43 AM
DIMENSIONS OF COOKING HOB AND WORKTOP
NOTES: In case of installation of a hood above the cooktop, please refer to the
hood instructions for the correct distance. |
|
|
|
|
|
|||||||
INJECTORS TABLE |
|
|
|
|
|
|
|
|
CATEGORY I2L |
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
Type of gas |
Type of |
Injector |
|
Rated |
|
Rated |
Reduced |
|
Gas pressure |
|||
used |
burner |
marking |
|
heat |
|
consumption |
heat |
|
|
|
|
|
|
|
|
|
capacity |
|
|
|
capacity |
|
min. |
rat. |
max. |
|
|
|
|
Pcs-kW |
|
|
|
Pcs-kW |
|
|||
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
NATURAL GAS |
large |
129 |
|
3.00 |
|
332 l/h |
0.60 |
|
|
|
|
|
medium |
99 |
|
1.65 |
|
183 l/h |
0.35 |
20 |
25 |
30 |
|||
(Methane) G 25 |
|
|
||||||||||
small |
78 |
|
1.00 |
|
111 l/h |
0.35 |
|
|
|
|
||
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
Type of gas |
Appliance |
|
Total rated |
|
Total rated |
|
Air required |
|
||||
used |
model |
|
heat capacity |
|
consumption |
|
for burning |
|
||||
|
|
|
Pcs-kW |
|
|
|
|
m3/h |
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
G 25 25 mbar |
4 gas |
|
7.30 |
|
|
809 l/h |
|
|
14.6 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|