This documentation is only intended tor qualilied technicians who are aware 01 the respective salety re-
gulations.
Date: 05.07. t994
Document-No.: 48t2 718 10692 Subject to modifK:ation
Register Nr.:
-" J
Technical Data 481271850043
"PROGRAM 94"
Free-standing models Range Band C
1. Dimension
Height 85 cm
Width 59,4 cm
Depth 60 cm
Weight 53 kg
Wrapping Shrink film
2. Specification ! PI-Expression
Wafer consumption 19,0 I
Energy consumption 1,5 kW/h
Program step app. 78 min
Noise level:
Range B 52 dB (A)
Range C klo 52 dB (A)
Detergent 25-75 ml
Separate contained chamber 1=113 I1 = 2/3
Salt consumption by 21 ° dh max. 30 gram
Hot wafer connection see type.. 60 °C
Capacity 12 standard plaGe settings
3. Volume
Water
Basic level 1 ,5 I
Working level 2,4 I
Dynamic level app. 4,6 I
Safety level 9,0 I
Overflow-level 12,5 I
Detergent max. 75 gram
Clear rinse 130 cm3
6 Dossier steps 1-6 cm3
Salt container 2 kg
4. Flow Rates !Inlet Volumes
Spray pump 70 I 1 min
Drain pump 16,5 I 1 min
Wafer inlet elctrovalve 5,5 I
5. Water Pressure
Inlet pressure 0,3-10 bar
Spray pump pressure 0,37 bar
6. Rotations
Spray pump motor 2800 r 1 min
Drain pump motor 2800 r 1 min
Spray arm lower 57 j: 7 r 1 min
Spray arm upper 34 j: 6 r 1 min
-J
7. Electrical Data
Base level
Voltage 220-230/50 VIV/Hz
Total power app. 3 kW
Fuses 16 A
Hot water connection up to 60 °C
Timer
Model Sibel EO P55
Basic step times 1", 15", 30", 120"
Range Band C = EO 5055 D
Heating
1 Element system: 220 V 2800 W app. 16,0 Ohm
230 V 3060 W app. 17,0 Ohm
2 Element system: (CH + DK )
Element A 220 V 1850 W app. 25,3 Ohm
Element B 220 V 950 W app. 49,5 Ohm
Motor
Spray pump motor 220 V/130 W HI=121 Ohm HA=30 Ohm
Capacitor 3 ~F
Drain pump motor 220/240 V 30 W 170 Ohm
Timer motor 220/240 V 7880 :t 400 Ohm
Valve
Inlet valve
Double valve 220/240 V 6 W 3620 Ohm
Regeneration valve 220/240 V 8 W 2300 Ohm
Relay 220/240 V 50/60 Hz 5500 Ohm
Thermostats Indication colour
Thermostat without 40 °C SP 40 :t 3 °C RSP 29 :t 5°C
Thermostat red 55 °C SP 55 :t 3 °C RSP 40 :t 5°C
Thermostat white 65 °C SP 68 :t 3° C RSP 57 :t 5°C
Housing colour red
Reset safety thermostat with manual reset SP 180 :t 7 °C
8. Water Levels
Basic level SP 90 :t 5 RSP 30 :t 5 mm ws
Working level SP 110:t 5 RSP 41 :t 5 mm ws
High pressure level SP 2900 + 200 RSP 2400 :t 200 mm ws
Safety level SP 135 :t 3 RSP 100 :t 5 mm ws
9. Water Measuring
Water level from fine sieve
Basic level 78 mm
Working level 100 mm
Safety level 136 mm
10. Regenerating Steps and Volumes
Figure Volumen Steps Water hardness
7000 481953028746 Hose, inlet aqua stop 4,2m
700 1 481248048019 Sieve
7002 481252058002 Gasket set
701 1 481231018153 Yoke clamp set
701 2 4819401 18423 Holder
7100 481241868108 Monoblock
7101 481936058381 Floater
7102 481931038536 Nut threaded ring set
7103 481946669562 Gasket set
7140 481946278885 Threaded cap cpl. salt