This documentation is only intended for qualified technicians who are aware of the respective safety re-
gulations.
Date: 20.01.1995
Document-No.: 481271811161 Subjecttomodification
Register Nr.:
1"...2 ,..
Technical Data 481271850043
"PROGRAM 94/95"
Free-standing models Range Band C
1. Dimension
Height 85 cm
Width 59,4 cm
Depth 60 cm
Weight 53 kg
Wrapping Shrink film
2. Specification I PI-Expression
Wafer consumption 19,0 I
Energy consumption 1,5 kW/h
Program step app. 78 min
Noise level:
Range B 52 dB (A)
Range C klo 52 dB (A)
Detergent ez.5-75 ml
Separate contained chamber 1= 1/3 II = 2/3
Salt consumption by 21 ° dh max. 30 gram
Hot wafer connection see type 60 °C
Capacity 12 standard place settings
3. Volume
Water
Basic level 1 ,5 I
Working level 2,4 I
Dynamic level app. 4,6 I
Safety level 9,0 I
Overflow-level 12,5 I
Detergent max. 75 gram
Clear rinse 130 cm3
6 Dossier steps 1-6 cm3
Salt container 2 kg
4. Flow Rates Ilnlet Volumes
Spray pump 70 I 1 min
Drain pump 16,5 I 1 min
Wafer inlet elctrovalve 5,5 I
5. Water Pressure
Inlet pressure 0,3-10 bar
Spray pump pressure 0,37 bar
6. Rotations
Spray pump motor 2800 r 1 mln
Drain pump motor 2800 r 1 min
) .
Spray arm lower 50 :t 6 r 1 min
Spray arm upper 26 :t 4 r 1 min
7. Electrical Data
Base level
Voltage 220-230/50 VIV/Hz
Total power app. 3 kW
Fuses 16 A
Hot water connection up to 60 °C
Timer
Model Sibel P55 EO
Basic step times 1", 15", 30", 120"
Range Band G = EO 5055
Heating
1 Element system: 220 V 2800 W app. 16,0 Ohm
230 V 3060 W app. 17,0 Ohm
2 Element system: (CH + DK )
Element A 220 V 1850 W app. 25,3 Ohm
Element B 220 V 950 W app. 49,5 Ohm
Motor
Spray pump motor 220 V/130 W HI=121 Ohm HA=30 Ohm
Capacitor 3 ~F )
Drain pump motor 220/240 V 30 W 170 Ohm
Timer motor 220/240 V 7880 :t 400 Ohm
Valve
Inlet valve
Double valve 220/240 V 6 W 3620 Ohm
Regeneration valve 220/240 V 8 W 2300 Ohm
Relay 220/240 V 50/60 Hz 5500 Ohm
Thermostats Indication colour
Thermostat without 40 °C SP 40 :t 3 °C RSP 29 :t 5°C
Thermostat red 55 °C SP 55 :t 3 °C RSP 40 :t 5°C
Thermostat white 65 °C SP 68 :t 3° C RSP 57 :t 5°G
Housing colour red
Reset safety thermostat with manual reset SP 180 :t 7 °C
8. Water Levels
Basic level SP 90 :t 5 RSP 30 :t 5 mm ws
Working level SP 110:t 5 RSP 41 :t 5 mm ws
High pressure level SP 2900 + 200 RSP 2400 :t 200 mm ws
Safety level SP 135:t 3 RSP 100:t 5 mm ws
9. Water Measuring
Water level from fine sieve
Basic level 78 mm
Working level 100 mm
Safety level 136 mm
10. Regenerating Steps and Volumes
Figure Volumen Steps Water hardness