NOTE TO INSTALLER: LEAVE THE OWNERS GUIDE MANUAL WITH THE APPLIANCE.
(Keep For Future Reference)
AU
RECORD HERE FOR EASY REFERENCE
Model Colour
Serial NumberInstallation Date
Dealer's Name and Address
GENERAL INFORMATION
ENVIRONMENTAL WARNING
Waste packaging
Do not throw the packaging of your appliance into the dustbin,
but pick out the different materials (for instance foil, paperboard,
polystyrene) according to the local rules for rubbish elimination.
This appliance must only be used for the purpose of domestic
cooking.
Getting to know your new cooker
Thank you for choosing one of our products.
Our cookers are of simple, rational design. They are
constructed to the best standards to ensure good
service and outstanding safety.
Please read this manual carefully; it will provide all the
advice needed to allow you to obtain the best results
from the very first day.
ATTENTION:
- Before using the appliance, do not forget to remove the
plastic protective film from
WARNING -Accessible parts will become hot when in use.
To avoid burns and scalds children should be kept away.
- WARNING -
In order to prevent accidental tipping of the appliance, for example
by a child climbing onto the open oven door, the stabilizing means
must be installed.
- WARNING
This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental capabilities,
or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance
by a person responsible for their safety.
Children should be supervised to ensure that they do not play
with the appliance.
Young children and infirm persons should not be left
unsupervised in the vicinity.
- WARNING
Before you use the appliance for the first time, check that the
plastic films protecting some parts (fascia panel, parts in stainless
steel, etc.) have been removed.
- WARNING:
A steam cleaner is not to be used cleaning this appliances.
- WARNING
DO NOT place inflammable materials or plastic utensils in the
warming drawer.
DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE
WHILE IT IS IN OPERATION.
Not for use in marine craft, caravans or mobile homes
unless each burner is fitted with a flame safeguard.
WHERE THIS APPLIANCE IS INSTALLED IN MARINE CRAFT
OR IN CARAVANS, IT SHALL NOT BE USED AS A SPACE
HEATER
Whirlpool Europa S.r.l.
Viale G. Borghi, 27
21025 Comerio (VA) Italy
When you call for service or order parts for your unit, be
sure to give:
1. MODEL
2. SERIAL NUMBER
3. COLOUR
4. PART NAME and/or description of problem
5. YOUR FULL NAME, ADDRESS, and HOME TELEPHONE
NUMBER and BUSINESS TELEPHONE NUMBER IF
APPROPRIATE.
SECTION FOR THE QUALIFIED TECHNICIAN
OVERALL DIMENSIONS
25
725
895
600
100
DO NOT MODIFY THIS APPLIANCE.
2
POSITIONING
If the range is placed on a base, ensure measures are taken
to prevent the product slipping off the base
Make sure that the wall surface behind the Cooker is noncombustable (will not catch fire). A plastered or tiled wall is ideal.
Where a painted surface is adjacent, a fire retardent paint surface
is recommended. Wallpaper, wood, or fabric should not be used
behind or next to the cooker.
Any adjoining wall surface situated within 200mm from the edge
of any hob burner must be suitable non-combustible material for
a height of 150mm for the entire length of the hob. Any combustible
construction above the hotplate must be at least 650mm above
the maintop.
INSTALLATION
PROVISION FOR VENTILATION
The room where the Cooker is installed should have permanent
ventilation as follows:
Ventilation must be in accordance with AS5601- 2004 - Gas
Installations. In general, the appliance should have adequate
ventilation for complete combustion of gas, proper flueing and to
maintain temperature of immediate surroundings within safe limits.
- Do not install in a bed-sitting room, a bathroom or shower room.
If there is another fuel burning appliance in the same room, a
higher level of ventilation will be required, you should consults
" the safety requirements".
In addition to the above, during prolonged use, opening a window
in the same room is recommended. This will avoid the build up
of excessive moisture and condensation.
POSITIONING
Important: Fix the chain located next to the gas connection on
both sides of the cooker to the wall to prevent the cooker from
tilting. Both chains must be securely fixed.
Make sure that the wall surface behind the Cooker is noncombustable (will not catch fire).
Where a painted surface is adjacent, a fire retardent paint surface
is recommended. Wallpaper, wood, or fabric should not be used
behind or next to the cooker.
Clearances to combustible materials
Any adjoining wall surface (side or rear) situated within 200mm
of any hob burner must be a suitable non-combustible material
from the edge for a height of 150mm for the entire length
of the cooker.
Any combustible construction above the cooker must be at least
650mm above the maintop. Ensure that a power and gas supply
are nearby. The Cooker should be located carefully so that the
heat produced by it has plenty of space to escape. The diagram
below shows an ideal configuration.
No part of any adjoining wall surface can be made of combustible
materials. The protection of combustible materials
required by Clause 5.12.1.1 of AS5601-2004 is the fixing of 5 mm
thick ceramic tiles to the surface or attaching fire resistant
material to the surface and covering with sheet metal with a minimum
thickness of 0.4 mm.
Clearances to non- combustible materials
If the cooker is being fitted next to cupboards or adjoing wall
surfaces, which are within 200mm from the edge of the hob
burner and of a suitable non-combustible material as specified
in AS5601, then ensure that a distance of at least 6cm is left
between the edge of the cooker and the non-combustible
material. This gap is to allow plenty of space for the heat
produced by the cooker to escape on each side of the cooker.
min "60" mmmin "60" mmmin "60" mm
"0" mm "0" mm
non- combustible materials
min. 650 mm
non- combustible materials
Note:
The cooker is fitted with 4 legs which must be assembled
as shown in figure 1B.
Fig. 1 B
OK
2
1
NO
min.100 mm
min.10 mm
min. 650 mm
"0" mm "0" mm
min. 400 mm
3
TO FIX THE COOKER TO THE REAR WALL
WARNING - For safety reasons and to prevent tipping of the appliance,
these stabilizing means must be installed.
The cooker is equipped with 2 chains fixed on each side at the rear of
the cooker near the top (see Fig. A). The chains are fitted with spring
clips which must be clipped to the screw eyes provided with the cooker.
Install the screw eyes as follows :
1. Drill four 6mm holes (position 1 - 2 - 3 - 4) in the wall
as in Fig. A.
2. Insert part R into the holes then screw in the screw eyes part
G see Fig. B.
Note: If the part provided is not suitable for the wall material please
use an appropriate device to ensure secure holding of the screw
eyes to the wall.
3. Bring the cooker near the wall and clip the chains on the
screw eyes as in Fig. C.
IMPORTANT: If the cooker is moved for any reason
(e.g. maintenance) resulting in the cooker being unclipped from the
wall, the cooker must be re-clipped to the wall at the completion of
the task.
55 mm
Position
2
Position
3
Position
4
55 mm
Position
1
chain
76 mm550 mm
GAS CONNECTION
Gas Installation must be made in accordance with AS5601;
also refer to rangehood manufacturers recommendations.
Check gas pressure, note the correct setting from the data plate
sealed inside the front appliance drawer .
*
Installing the Gas Cooker:
(Flexible connections are NOT permitted with this
appliance)
· An inlet manifold extension pipe must be fitted to the
appliance. Part supplied in the drawer of the appliance.
· Ensure that the pipe is connected using the washer provided
and that the bracket is screwed to the appliance as shown in
the diagram below.
Fit the supplied pressure regulator. Ensure the arrow is pointing
·
towards the appliance and that the pressure test point is
accessible from under the appliance when the product is pushed
back into the final position.
Push the cooker back and install the stabilizing chains.
Connect the appliance inlet manifold to the fixed consumer
piping outlet using only fixed piping. This final connection is
made when the product is pushed back into position by access
under the cooker.
Fig. A
Fig. B
GRHole
wall
Fig. C
wall
Washer
Screw
G
Inlet Manifold Extension.
Supplied with product.
To be fitted by installer
Regulator
Fixed Pipe to
Connection Point
IT IS RECOMMENDED THAT A SERVICE TAP AND UNION BE
FITTED ADJACENT TO THE APPLIANCE INLET TO FACILITATE
FUTURE SERVICING.
5 burner models: set the burner pressure to 1kPa for Natural Gas
and 2.75kPa for U-LPG with the wok burner operating a full rate.
For commissioning of the appliance with the Bromic regulator for
Natural Gas , the test point pressure should be 1.00kPa with all
burners operating on HIGH.
Apply a manometer to the test nipple and reset the regulator if
necessary. Do not forget to replace the test nipple screw and to
leave the instruction book with the user.
This appliance from the factory suitable for NATURAL gas but, if
necessary, can be adjusted for U-LPG by authorised person.
For the adjustments to U-LPG please operate as specified in the
paragraph GAS CONVERSION AND ADJUSTMENT (pag 4).
The Gas Connection is male 1/2" BSP and is situated at the right or left,
hand rear of the appliance, approximately 40mm from the side
The appliance shall be installed by an authorized person in
accordance with the manufacturers installation instructions,
relevant local fitting regulations, municipal building regulations,
the AS5601 code for gas burning appliances and equipment and
4
other relevant statutory code band regulations. If you have some
doubts, please contact the authorities for confirmation concerning
the characteristics of the gas and electricity output.
The appliance is generally preset for natural gas (so no other
adjustment is necessary) ensure regulator is fitted for N.G.
Ensure that all foreign matter has been cleared from the gas
supply line and also purge all air from the gas system. Connect
to regulator, tighten and check the installation to ensure no gas
leaks occur.
VERY IMPORTANT FOR THE INSTALLER
Do not attempt to turn or stress threaded elbow of the manifold:
you risk damage to this part of the gas appliance which may void
the manufacturers warranty.
Before Leaving Check all connections for gas leaks.
DO NOT use a naked flame for detecting leaks. Ignite all
burners to ensure correct operation of gas valves, burners and
ignition. Turn gas taps to low flame position and observe
stability of the flame.
When satisfied with the cooker, please instruct the user on the
correct method of operation.
In case the appliance fails to operate correctly after all checks
have been carried out, refer to the authorised service provider
in your area.
GAS CONVERSION AND ADJUSTMENT
When used with natural gas all burners have been preset at our
factory and further adjustment should not be necessary. Conversion
kits to other gases are available from the place of purchase. Do
not attempt to fit the conversion kit yourself. Conversion to U-LPG
gas should only be carried out by an authorized technician.
GAS ADJUSTEMENTS
- change the injectors
- adjust the minimum flow
When converting from Natural Gas to U-LPG ensure that
the NG regulator is removed and replaced with the Test Point
Assembly. A gas regulator suitable for a supply pressure of 2.75kPa
should be part of the gas tank supply and should be adjusted with
the wok burner operating at maximum.
REPLACEMENT OF THE INJECTORS
When required to operate on other gas replace the injectors in
accordance with information referred to in chart below.
TA B. 1
Gas Type
kPa
Jet mm ØBurners Power MJ/h
0.90Auxiliary 4.0
Natural Gas 1.00 kPa
1.20 Semi-rapid
1.50Rapid 11.0
7.1
1.63 Wok12.7
0.53Auxiliary 3.7
U - LPG 2.75 kPa
0.73 Semi-rapid7.0
0.95Rapid 11.7
1.00 Wok12.7
- change the injector (see Fig. 1A) and replace it with another
one suitable for the new type of gas (see tab. 1)
Fig. 1A
MINIMUM FLOW ADJUSTMENT FOR HOB-TOP TAPS
In order to adjust the minimum flame setting proceed as follows:
switch the burner on, and set the knob at the minimum position
. Remove the knob from the tap, place a small bladed screwdriver
down the centre of the tap shaft (fig. 2A).
Attention: on taps with a security valve, the minimum adjusting
screw «Z» is on the body of the gas tap (fig. 2B).
Z
Fig. 2BFig. 2A
Unscrew the adjusting screw in order to increase the flow or screw
it to decrease the flow.
The correct adjustment is obtained when the flame has a length
of about 3 or 4 mm.
For butane/propane gas, the adjusting screw must be screwed
in thigt.
Make sure that the flame does not go out turning quickly from the
max. flow to the minimum flow .
Refit the knob again.
SPECIAL NOTE
After installation or any servicing operation, always ensure that
the appliance is gas sound and that the components are now
operating correctly. Items removed during servicing should be
replaced in the reverse order to their
removal.
In order to change the work-top injectors,
it is necessary to act as follows:
- remove the grids
- remove burners
and flame-spreaders.
5
Loading...
+ 11 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.