Whirlpool ACC602XP0 User Manual [en, es]

ROOM AI R CO NDI TIO NER S

Use & Care Guide

Removable filter Control panel
^
Adjustable air discharge
-----------
Part No. 1162825

Conte nts

Impor ta nt S afe ty
Important Safety Instructions Operating instructions
Starting your air conditioner
The exhaust vent control................................4
Changing air direction
Cleaning Your Air Conditioner
Cleaning the front panel.................................5
Cleaning the filter...........................................5
Caring For Your Air Conditioner
Annual maintenance
if You Need Service Or Assistance Warranty
Thank you for buying this appiiance. Piease compiete and maii the Owner Registration Card provided with this product. Then com
plete the form below. Have this information ready if you need service or call with a question.
• Copy model and serial numbers from label (see diagram below) and purchase date from sales slip.
• Keep this book and sales slip together in a handy place.
Model Number
Serial Number
Purchase Date
Service Company Phone Number
Front view of unit with front panel removed
Appliance cable
..........................................................
....................................
......................................
........................
...................................
...........................
......................
...................
...............
3 3
4 4
5 5 7
2
Instr uc tion s
^WARNING
To reduce the risk of fire, eiectricai shock or personal injury when using your air conditioner, foliow these basic precau tions:
• Read ali instructions before using your
air conditioner.
8
• Compiete the instaliation requirements as
described in the instaiiation instructions.
■ Never aliow chiidren to operate or play
with the air conditioner.
• Do not operate the air conditioner with
the front panei removed.
• Never ciean air conditioner parts with fiammabie fiuids. The fumes can create a fire hazard or expiosion.

• FOR YOUR SAFETY«

DO NOT STORE OR USE GASOLiNE OR OTHER FLAMMABLE VAPORS AND LiOUiDS iN THE ViCiNiTY OF THiS OR ANY OTHER APPLiANCE. THE FUMES CAN CREATE A FiRE HAZARD OR EXPLOSiON.
It is your responsibility to be sure your air conditioner:
• Is Installed in a window that will hold the weight, and is secured according to the Installation Instructions.
• Is connected only to the proper kind of outlet, with the correct electrical supply and grounding. (See Installation Instructions.)
• Is the correct size for the area you want to cool.
• Is used only to do what window air condition ers are designed to do.
• Is not used by anyone unable to operate it properly.
• Is properly maintained.
Also, remove the Energy Label. Use a damp cloth to take off any glue residue. Do not use sharp instruments, flammable fluids or abrasive cleaners. These can damage the material.

- SAVE THESE INSTRUCTIONS -

Model and serial number label
Handle

Oper ati ng Ins tru cti ons

Starting your air conditioner
1. Set the Exhaust Vent Control to CLOSED
CLOSED ^
2. Set the Selector to the desired setting.
SELECTOR
3. Set the Fan Control to the desired setting.
^WARNING

Electrical Shock Hazard

• Plug unit only into grounded electrical
outlet.
• Do not use an extension cord.
• Do not operate unit with front removed. Failure to follow the above precautions
could result in electrical shock or personal injury.
for maximum cooling or heating.
COOL
...............................
HEAT ................................for heating room air
FAN ONLY
NOTE: This product is not designed to be used as a primary heat source. It is intended
for supplemental heating only.
HI
...................
MED LO
..................................................
..................
for maximum cooling or heating
..................
for normal cooling or heating
for cooling room air
for circulating room air
when no cooling or
heating is desired
for sleeping comfort
4. Turn the Thermostat Control to desired setting. You can adjust the air conditioner’s cooling or heating performance by resetting the Thermostat Control toward COLDER for more cooling. Turn toward WARMER for more heating. You will need to experiment to find
the setting which suits you best.
NOTE; If you turn your air conditioner off or if the
compressor turns off when lowering the Thermo stat Control, wait at least three minutes before turning it back on or you may blow a fuse or trip a circuit breaker.

Operating Instructions Continued

The exhaust vent control
The Exhaust Vent Control setting draws stale or smoky air from the room.

1. To exhaust room air:

Set Exhaust Vent Control to OPEN. Set Selector to desired setting (COOL, HEAT or FAN ONLY). Set Fan Control to desired fan speed. Set Thermo stat Control to desired setting.

2. To circulate room air:

Set Exhaust Vent Control to CLOSED. Set Selector to desired setting (COOL, HEAT or FAN ONLY). Set Fan Control to desired fan speed. Set Thermostat Control to desired setting.
NOTE: For maximum performance, the Exhaust Vent Control must be in the CLOSED position when cooling, heating or room air circulation is desired.
Changing air direction
The air direction cartridges on both sides of the unit control the direction of the cooled or heated air. The air direction cartridge may be rotated to direct the air straight ahead or to the side of the unit.
The louvers in each air direction cartridge are operated by a tab. The tab may be used to direct the air up, down or straight ahead.

Clean in g Y our Ai r C ondi tio ner

Proper use and care of your air conditioner will help ensure longer life of the unit and lower operating costs. Follow these instructions
carefully. Call your Whirlpool servicing dealer for an annual checkup.
Awarning

Electrical Shock and Fire Hazard

• Unplug power cord from receptacle before cleaning unit. Failure to do so could result in electricai shock or per sonal injury.
• Do not use flammable fluids, soivents, abrasive cleaners, or strong detergents. Fire or product damage could result.
Filter
Screw
Screw
Cleaning the front panel
1. UnpiLfg power cord.
2. Remove the front panel from unit when cleaning. Remove two screws from bottom edge of front panel.
3. Lift the front panel up and toward you.
4. Remove slide-out filter and clean separately. (See “Cleaning the filter” below.)
NOTE: Front does not have to be removed to clean filter.
5. Clean front panel with warm water and mild soap or detergent. Use a soft cloth. Rinse and dry. Replace front panel.
6. Wipe control panel clean with a soft, dry cloth.
Cleaning the filter
The filter is cleanable. A clean filter helps remove dust, lint and other particles from the air. Check every two weeks to see if filter needs cleaning.
1. Remove filter by sliding the filter up and out the top of front panel.
2. Clean filter, using a vacuum cleaner. OR
3. If very dirty, wash filter with warm water and
mild detergent. Air dry thoroughly before replacing.
4. Replace filter by sliding it back down into opening at the top of front panel.

Cari ng For You r Air Con dit ion er

Annual Maintenance
Your air conditioner needs annual maintenance
to help ensure steady, top performance through
out the year.
Call the service company recommended by
your dealer to:
• Inspect and clean the coils and condensate water passages.
• Check fan and fan motor.
The compressor and fan motor are sealed and
need no oiling. Expense of annual inspection is
customer’s responsibility.
OR
If you are familiar with electrical appliances, you can do the cleaning and maintenance yourself. If you choose to do so, follow the steps on page 6.