W E1 -ADJUSTMENTS AND WATER LEVELS
W F1 -DIAGRAMS AND PROGRAMME CHART
W G1 -EXPLODED VIEWS AND SPARE PARTS LIST,
..Ii;
j
(
l
t,
t,
( .Subject to modification
4819 729 68284 (N-SF)
Printed in Italy -GL 0989 -Ed. 01:
(
t
y
r AWG 752 PH -W A1
r TECHNICAL DATA
( GENERAL
Front loading automatic washing machine, variable spin-drying speed tram 120 to 1000 r.p.m., load capacity 4.5 kg dry
( laundry.
Model: AWG 752 PH -10 programmes and the possibility of
( more combinations.
Mains voltage: 220 V :t: 10% -50 Hz
(
Max. power consumption: approx. 2200 W
(
\. Connections:
(Water supply: inlet hose 1.40 m lang, provided with 3/4" coupling!
I: Height: about 850 mm
Mains fuge: .'10 A
Electrical: Three cables 3 x 1.0 -1.50 m lang (Europlug);
Water draining: drain plastic flexible hose, fitted with a bent remova-
Heating element: approx. 2200 W
Dimensions:
Width: about 596 mm
Depth: about 520 mm
Weight
Packed machine: about 82 kg
Unpacked machine: about 79 kg
,
nuts!
ble hose guide, 1.50 m lang.
Height should be between 60 cm and 90 cm
Base support: by means of 4 adjustable feet.
MOTOR
Direct current version with permanent magnets.
The stator includes the ferroxdure permanent magnets.
The rotor contains the laminated soft iran Gare, the coils and the commutator.
Two brush hotders, which contain 2 carbon brushes, are placed opposite each other. The carbon brushes rest on the
commutator to provide a sliding contact to pass current.
The motor shaft is equipped with an insulated pulley, Service Code ofthe insulated pulley does not appear because it is
not replaceable.
The motor is ted by the "Control unit" which supplies the different vortages required, depending on the speed.
I
l
(
i
\.
l
Ed. 01 -Sep. 89
l.
!"~1~;oo$'!~" v, ...~,7'~"'y ~
AWG 752 PH -W A2 C)
~ \
POLYMOTOR 1 -Mains Voltage 220 V 3 -High water level a ;.
MOTOR 2 -Potentiometer knob in position Max. 4 -Without laundry .,
Notice I (Absorption) V (Voltage) W (Power consumption) 8
Main wash "" 4.5 A "" 18 V "" 81 W
Pre-spinning "" 2 A ~ 33 V "" 66 W e
(final value) (final value)
Spinning "" 2 A ~ 205 V "" 410 W ()
750 r.p.m. approx. (final value) (final value)
Spinning "" 2.8 A ~ 240 V "" 460 W ~ l
920 r.p.m. approx. (final value) (final value) .
U~
~
Note:
The above mentioned values are referred to a mains of 220V.
The spinning data found in use may be different, depending on the voltage, laundry load and on the unit characteristics
(tolerances).
MOTOR ROTATION SPEED f
( "
"
.
(Mains voltage = 220 VI Potentiometer knob in pos. Max -high water level without laundry). l
Main wash: approx. 800 r.p.m.
Pre-spinning: approx. 1600 r.p.m.
Spinning low: approx. 10000 r.p.m. (approx. 750 r.p.m. of the drum) (
high: approx. 12500 r.p.m. (approx. 950 r.p.m. of the drum)
TRANSMISSION RATIO (
Drum, motor pulley: 1/13.2
DRUM ROTATION SPEED (
(Mains voltage = 220 V Potentiometer knob in pos. Max. -high water without laundry) l
Main wash: approx. 55 r.p.m.
Pre-spinning: approx. 116 r.p.m. (
Spinning low: approx. 750 r.p.m.
high: approx. 950 r.p.m.
Note: In the timer P~sitions with slow rotation + heating, the water is heated during the motor stop periods. l
ROTATION RHYTHM l .
Normal: 7.5" clockwise
7.5" stop
7.5" counter-clockwise L
Slow: 3" clockwise
-12" stop I
3" counter-clockwise 1\.j
Ed. 01 -Sep. 88
L
I
""
r A WG 752 PH -W A3
r ROTATION TIME," '
( Normal:
The normal rhythm is effected by means of the fast cam disc (3) wh ich, by means of a mechanical arrangement in the
(timer, allows slowcam disc 5 to operate as a fastone. Then, by closing contacts 3.25 and 5.25there will be 7.5" rotation in
clockwise direction, and by closing contacts 3.33 and 5.35 there will be 7.5" rotation in counter-clockwise direction,
while with contact 1-31 open there will be a stop of 7.5".
( ~
The slow rhythm is obtained by the closing of the same contacts of the normal rhythm and of the contacts 4-24 and 2-32.
When contacts 4-24 and 2-32 are closed there is no revolution of the drum tor 3", as the motor is not ted by the electronic
( mode. When contacts 4-24 and 2-32 are open, the drum stops tor 12".
( DRAIN PUMP
The reverse revolution of the drum, as previously described, takes plaGe by the closing of contacts 3-23,5-25 I 3-33 and
5-35.
( Rotation speed: approx. 2500 r.p.m.
t ( min. 60 cm
, ..The pump motor is electrically protected by a thermal protector.r
.c~" 'c.
Power consumption: approx. 90 W
Capacity: approx. 20/25 I/min
Height of draining hose: max. 90 cm
, (
r.. WATER VALVE PRE-WASH
i .
Pressure: 0.5/10 kg cm2 (5/100 N/cm2)
Capacity: 10 I/min
WATER VALVE WASH
I Pressure: 0.5/10 kg cm2
Capacity: 10 I/min
The body is common tor both valves and incorporates a filter to retain water impurities.
PRESSOSTAT .with 4.5 kg with 2 kg
(three levels) wlthout laundry standards fine fabrics
Low level 9 :t 1 I 17 :t 1 I 12 :t 1 I
High level 13 :t 1 I 22 :t 1 I 15 :t 1 I
Extra high level 21 :t 1 I 25 :t 1 I 18 :t 1 I
OVERFLOW PROTECTION PRESSOSTAT
This pressostat will switch on the drain pump when the quantity of water in the tub exceeds approx. 36 liters.
TIMER
A Graulet type with 60 impulses -Type 914/1393.
The timer programme chart includes 3 basic programmes (normal, delicate and wool programme), 3 stop positions and 3
( start positions. Besides, on positions 26 and 44 there is an optional rinse stop (stop with water in the tub).
l
(
l
l.
Ed. 01 -Sep. 89
{
,'- ~
0.
..
AWG 752 PH -WA4 0
PUSH BUTTON SWITCH f'
Aversion with 2 buttons having switches tor: on/off .-
gentle wash .-
POTENTIOMETER 8
A rotative logarithmic type -resistance value: 1 M Q (infinite resistance at end clockwise rotation caused by open con-
tacts).
THERMOSTATS
e
In the washing machine there are: #1
'-1
A) A fixed deviation thermostat with single temperature directly connected to the timer motor, normally closed, with the
following features: TH 40 °C: opening 37 :t 3 °C ..'
(recognizable by 2 grey marks) closing > 24 °C .
B) An adjustable thermostat with a nominal rating of 10°C -+- 90 °c (normally closed) while at the low start position (0 ~
point) mechanically open. .
The thermostat contacts are normally closed at a setting between 10°C -30 °c. Under influence of the ambient -or
not energized.
C) A fixed thermostat, normally closed, with the following features: (
-opening 103 °c
-closing approx. 81°C
Its function is to disconnect the heating element in case heating without water in the tub should occur. (
(incoming water temperature it might happen that the thermostat contacts are not closed and the heating element is
(
{
(
l
(
..L '
l .
~
~,!
"" ,,",' -c:;"'",",'u..", -."
L
L.