of the cable and pull the slack. Run the other end of the cable down and under pulley
located at the base of the leg. Repeat the same procedure for the other leg assembly.
6) Layout lift location using FIG. #1B. Maximum width of lift is 11’-6 ½” and minimum
is 10’-6 ½”. Lift moves in at 6” increments.
7) Leg assemblies should be mounted on a CONCRETE FLOOR ONLY with a
minimum thickness of 4 inches and a maximum slope not to exceed 1/16” per foot.
8) Stand leg assemblies up and position as shown in FIG. #1B.
9) Make sure the 9’-7” inside measurement leg to leg is maintained. DO NOT
ANCHOR AT THIS TIME. Depending on customers preference, lift may be moved
in 6” increments to 8’-7” inside measurement.
10)NOTE: One leg has a power unit bracket. This is the leg (Mainside) that the pumping
unit will mount to and the electrical service will be wired to. FACTORY
RECOMMENDED LOCATION IS TO THE REAR PASSENGER SIDE OF
VEHICLE.
11)Check leg (with pump mount bracket) for plumpness using a good spirit level in both
directions. Use shims (1/16” x 1 x 2 ½” and ¼” x 1” x 2 ½”) provided as necessary
for proper leveling. (Do not exceed ½” total shim height). DO NOT ANCHOR
NON-POWER COLUMN AT THIS TIME.
12)Drill and set ¾” anchor bolts. (Ref. Anchoring Tips) Use washers when final
tightening is done. Make sure all bolts are properly set and meet 125 ft. lbs of torque.
DO NOT USE AN IMPACT.
13)Check inside measurements between both columns at top and bottom to insure they
are parallel.
14)Lift Cross Bridge Assembly as shown in FIG. #2A or #2B to the top of the leg
assemblies with Switch Box assembly on the side of the power unit. Secure assembly
as shown in FIG.#3 using the (4) 7/16-14UNC x 1 1/2” bolts, (8) 7/16 flat washers,
(4) lock washers and (4) 7/16-14UNC hex nuts. Bolts heads are to be placed on the
outside with the nuts on the inside.
15)Next assemble and install the Single Point Release Pulley Bracket as shown in FIG.#3
with the LH/RH Single Point Rel. Weldm’t., (4) ¼ flat washer, (2) Pulley Sheave, (2)
1/16” Cotter Pin, (2) 7/16-14UNC x 1 1/2” bolts, (4) 7/16 flat washers, (2) lock
washers and (2) 7/16-14UNC hex nuts.
16)Attach the power unit to the main side leg using the (4) 5/16-18UNC x 1” bolts, (8)
5/16-18UNC hex nuts, and (4) 5/16 lock washers.
17)Next locate lock release handle, 7/8” retainer rings, 1/16” wire rope (25’-0”), 1/16”
wire rope clip and (1) 1/16” oval sleeves. Switch out shipping pin with handle on
safety latch bracket, which is located on the back of the main side leg. Secure in place