SideKick™
Bezel
Fender
Opening
Retaining
Tab
SideKick™ V Series Fender Light
SideKick™
Bezel
Fender
Opening
Retaining
Tab
ENGINEERING COMPANY INC.
51 Winthrop Road,
Chester, Connecticut 06412-0684
Phone: (860) 526-9504
Fax: (860) 526-4078
Internet: www.whelen.com
Sales e-mail: autosale@whelen.com
Canadian Sales e-mail: canadiansales@whelen.com
Customer Service e-mail: custserv@whelen.com
Installation:
1. Remove the vent panel from the vehicle per manufacturers instructions.
2. Install the V Series lighthead into the SideKick panel using the 2 supplied
washer head screws.
3. Extend the lighthead wires into the fender and to their
appropriate designations. Refer to the reverse side of this
document for wire colors, functions, fuse values and
switch information.
4. Install the SideKick panel, making sure all
of the retaining tabs are fully engaged
and locked into place.
IMPORTANT: Before returning
the vehicle to active service,
visually confirm proper
operation of this product as well
as all vehicle components/equipment.
Installation Guide:
2012 - 2013 Chevrolet Caprice
Automotive: Lightheads
©2013 Whelen Engineering Company Inc.
Form No.14721(080713)
ENGINEERING COMPANY INC.
51 Winthrop Road,
Chester, Connecticut 06412-0684
Phone: (860) 526-9504
Fax: (860) 526-4078
Installation:
1. Remove the vent panel from the vehicle per manufacturers instructions.
2. Install the V Series lighthead into the SideKick panel using the 2 supplied
washer head screws.
3. Extend the lighthead wires into the fender and to their
appropriate designations. Refer to the reverse side of this
document for wire colors, functions, fuse values and
switch information.
4. Install the SideKick panel, making sure all
of the retaining tabs are fully engaged
and locked into place.
IMPORTANT: Before returning
the vehicle to active service,
visually confirm proper
operation of this product as well
as all vehicle components/equipment.
For warranty information regarding this product, visit www.whelen.com/warranty
Installation Guide:
SideKick™ V Series Fender Light
2012 - 2013 Chevrolet Caprice
Internet: www.whelen.com
Sales e-mail: autosale@whelen.com
Canadian Sales e-mail: canadiansales@whelen.com
Customer Service e-mail: custserv@whelen.com
Automotive: Lightheads
©2013 Whelen Engineering Company Inc.
Form No.14721(080713)
Page 1
For warranty information regarding this product, visit www.whelen.com/warranty
SignalAlert™ 75 / phase 1
SignalAlert™ 75 / phase 2
CometFlash® 75 / phase 1
CometFlash® 75 / phase 2
DoubleFlash 75 / phase 1
DoubleFlash 75 / phase 2
SingleFlash 75 / phase 1
SingleFlash 75 / phase 2
ComAlert™ 75 / phase 1
ComAlert™ 75 / phase 2
LongBurst™ 75 / phase 1
LongBurst™ 75 / phase 2
PingPong™ 75 / phase 1
PingPong™ 75 / phase 2
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
Flash Patterns (SYNC)
SingleFlash 60
SingleFlash 90
SingleFlash 120
SingleFlash 300
DoubleFlash 150
ComAlert™ 150
ActionFlash™ 50
ActionFlash™ 150
ModuFlash™
ActionScan™
Steady
19.
20.
21.
22.
23.
24.
25.
15.
16.
17.
18.
Flash Patterns (NON SYNC)
Light
BLK
GRY
WHT/VIO (Scan-Lock)
RED (Warning)
WHT/RED ( )Puddle
WHT/BLK ( )Alley
SP/ST
SP/ST
SP/ST
Mom. SW
1 Amp
3 Amp
1 Amp
3 Amp
+12VDC
+12VDC
+12VDC
+12VDC
To Chassis Ground
To SYNC wire of other SYNC capable light
WIRING DIAGRAM
Wiring:
CAUTION! DO NOT LOOK DIRECTLY AT THESE LED’S WHILE THEY ARE ON.
MOMENTARY BLINDNESS AND/OR EYE DAMAGE COULD RESULT!
IMPORTANT WARNING!
SignalAlert™ 75 / phase 1
SignalAlert™ 75 / phase 2
CometFlash® 75 / phase 1
CometFlash® 75 / phase 2
DoubleFlash 75 / phase 1
DoubleFlash 75 / phase 2
SingleFlash 75 / phase 1
SingleFlash 75 / phase 2
ComAlert™ 75 / phase 1
ComAlert™ 75 / phase 2
LongBurst™ 75 / phase 1
LongBurst™ 75 / phase 2
PingPong™ 75 / phase 1
PingPong™ 75 / phase 2
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
Flash Patterns (SYNC)
SingleFlash 60
SingleFlash 90
SingleFlash 120
SingleFlash 300
DoubleFlash 150
ComAlert™ 150
ActionFlash™ 50
ActionFlash™ 150
ModuFlash™
ActionScan™
Steady
19.
20.
21.
22.
23.
24.
25.
15.
16.
17.
18.
Flash Patterns (NON SYNC)
Light
BLK
GRY
WHT/VIO (Scan-Lock)
RED (Warning)
WHT/RED ( )Puddle
WHT/BLK ( )Alley
SP/ST
SP/ST
SP/ST
Mom. SW
1 Amp
3 Amp
1 Amp
3 Amp
+12VDC
+12VDC
+12VDC
+12VDC
To Chassis Ground
To SYNC wire of other SYNC capable light
WIRING DIAGRAM
CAUTION! DO NOT LOOK DIRECTLY AT THESE LED’S WHILE THEY ARE ON.
MOMENTARY BLINDNESS AND/OR EYE DAMAGE COULD RESULT!
IMPORTANT WARNING!
WARNING: All customer supplied wires that connect to the positive terminal
of the battery must be sized to supply at least 125% of the maximum
operating current and FUSED at the battery to carry that load.
DO NOT USE CIRCUIT BREAKERS WITH THIS PRODUCT!
Ground (BLK) - Extend to chassis ground.
Warning Light (RED) - Extend to +12VDC via an SP/ST switch (fuse @ 3A).
Alley Light (WHT/BLK) - Extend to +12VDC via an SP/ST switch (fuse @ 3A).
Puddle Light (WHT/VIO) - Extend to +12VDC via an SP/ST switch (fuse @ 1A).
Scan-Lock (GRY) - Extend to +12VDC via an MOM switch (fuse @ 1A).
SYNC (GRY) - See below.
Operation:
Scan-Lock™ - Note: The light must be on to change patterns.
To advance to next pattern: Apply +VDC to the WHT/VIO wire for less than 1
second.
To cycle backwards: Apply +VDC to the WHT/VIO wire for more than 1 second.
To reset to the factory default pattern: Turn off power to the light. While
applying +VDC to the WHT/VIO wire, turn the light back on. Continue to apply
voltage for 5 seconds.
SYNC - Lights configured to display the Phase 1 mode of a pattern will flash
simultaneously. Lights configured to display the Phase 2 mode will alternate with any
Phase 1 lights with the same pattern.
To sync two lights, configure both lights to display the same Phase 1 pattern. Turn
power off and connect the GREY wires from each light together. When the lights are
activated, their patterns will be synchronized. To configure the two lights to alternate
their patterns, advance the pattern of either lights to Phase 2 of the current pattern.
Wiring:
WARNING: All customer supplied wires that connect to the positive terminal
of the battery must be sized to supply at least 125% of the maximum
operating current and FUSED at the battery to carry that load.
DO NOT USE CIRCUIT BREAKERS WITH THIS PRODUCT!
Ground (BLK) - Extend to chassis ground.
Warning Light (RED) - Extend to +12VDC via an SP/ST switch (fuse @ 3A).
Alley Light (WHT/BLK) - Extend to +12VDC via an SP/ST switch (fuse @ 3A).
Puddle Light (WHT/VIO) - Extend to +12VDC via an SP/ST switch (fuse @ 1A).
Scan-Lock (GRY) - Extend to +12VDC via an MOM switch (fuse @ 1A).
SYNC (GRY) - See below.
Operation:
Scan-Lock™ - Note: The light must be on to change patterns.
To advance to next pattern: Apply +VDC to the WHT/VIO wire for less than 1
second.
To cycle backwards: Apply +VDC to the WHT/VIO wire for more than 1 second.
To reset to the factory default pattern: Turn off power to the light. While
applying +VDC to the WHT/VIO wire, turn the light back on. Continue to apply
voltage for 5 seconds.
SYNC - Lights configured to display the Phase 1 mode of a pattern will flash
simultaneously. Lights configured to display the Phase 2 mode will alternate with any
Phase 1 lights with the same pattern.
To sync two lights, configure both lights to display the same Phase 1 pattern. Turn
power off and connect the GREY wires from each light together. When the lights are
activated, their patterns will be synchronized. To configure the two lights to alternate
their patterns, advance the pattern of either lights to Phase 2 of the current pattern.
Page 2