Whelen 90192 User Manual

®
ENGINEERING COMPANY INC.
Route 145, Winthrop Road, Chester, Connecticut 06412 Phone: (860) 526-9504 Fax: (860) 526-2009 Internet: www.whelen.com Sales/Service e-mail: aviation@whelen.com
Installation Guide
Model 90192 - ( )
Strobe Anti-collision Power Supply
MADE IN THE U.S.A.
TSO-C96a
APPROVED
90192-( ) STROBE ANTI-COLLISION POWER SUPPLY ASSEMBLY OPERATING INSTRUCTIONS. Nominal Operational Voltage: 14 VOLTS / 28 VOLTS Average Input Current: 4 AMPS / 2 AMPS Output Voltage: 550V Nominal
EQUIPMENT LIMITATIONS: Recommended minimum wire size is
20 AWG and is installation dependant to meet FAR requirements for light output. Avoid moisture, salt or dust environment.
INSTALLATION PROCEDURES: The following information is to assist you in installing a Whelen anti-collision light power supply. Install in accordance with AC 43.13-1A and 2A.
1. Choose the appropriate Model 90192-( ) replacement power supply which is applicable to your aircraft.
2. The installation procedure described in the following text will be confined to a “single light” power supply, but is identical for multiple power supply installation if required.
3. Remove old power supply, locate and save existing +14 VDC or+28 VDC lead and (-) ground leads. Clean and prep lead ends as required.
4. Use existing mounting holes and hardware.
NOTE: If a special mounting adapter plate is required, contact Whelen Aviation Division for requirements.
5. Connect existing +14 VDC or +28 VDC lead to the POSITIVE (+) lead on the power supply assembly and connect existing (-) ground lead to the NEGATIVE (-) lead on the power supply assembly. Both leads must be connected by an approved aircraft connection.
6. Make sure existing system is equipped with an appropriate sized breaker.
7. Check all avionics systems for interference from this installation.
8. A flight check should be performed by a properly certified pilot.
9. Update aircraft records and complete Form 337.
10. Obtain FAA field approval for installation.
Aviation
INPUT
PIONEERSIN SAFETY SIGNALS
ENGINEERINGCOMPANY,INC.
CHESTER,CONNECTICUT 06412-0684
MODEL 90192
14VDC @ 4A 28VDC @ 2A
WEIGHT 2.1 lbs.
MFG.DATE:
SERIAL NUMBER:
WARNING
HIGH VOLTAGE
Wait5 minutes after shutting
off before starting any work on
the StrobeLight Sytem.
CAUTION:DC UNITS ARE
POLARITYSENSITIVE.
Black lead is negative.
NOTICE:DO NOT TAMPER
WITHPOWER SUPPLY.
This unit is sold as a
COMPLETE MODULE, not
designed for field repair.
Returnto authorized repair facilties.
6.181
OUTPUT
3.938
SUGGESTED MOUNTING PLAN
©1997 Whelen Engineering Company Inc. Form No.13225C (091697)
Page 1
10.130
6.929
2X 1.600
3
.53
1
2
1.77
2.45
3.540
3.938
4.606
4
4X .187
1.895
6.181
5
1.875
01--0790192-00 (3-PIN)
MS3102R10SL-3P
CONN. (REF) OR EQUIVALENT
MS3106E10SL-3S
MATING CONN. (REF)
C=SYNCHRONIZATION
WIRING
A=POWER(+)
B=GROUND(-)
.06 TYP
MODEL 90192 REPLACEMENT PARTS
1
MANUFACTURING LABEL
2
LABEL, INPUT
3
LABEL, OUTPUT
4
CAP, PLUG
5
POWER SUPPLY MODEL# YQL14 / 28Q4516-1VA
MANUFACTURING LABEL
1
LABEL, INPUT
2
LABEL, OUTPUT
3
CAP, PLUG
4
POWER SUPPLY MODEL# YRL14 / 28Q4516-1VA
5
01--0790192-01 (6-PIN)
MS3112E10-6P CONN. (REF)
OR EQUIVALENT MS3116F10-6S
MATING CONN. (REF)
WIRING
A=28VDC(+) STROBE LIGHT B=GROUND(-) STROBE LIGHT C=SYNCHRONIZATION D=28VDC(+) POSITION LIGHT E= F=GROUND(-) POSITION LIGHT
-( )
DESCRIPTION USED ONPART NUMBERITEM
CONN. (REF) OR EQUIVALENT
.97
10-0530751-02 10-0330753-02 10-0330774-02 22-0430469-00 01-0268151-00
10-0530778-02 10-0330779-02 10-0330780-02 22-0430469-00 01-0268187-00
01--0790192-00 (3-PIN) 01--0790192-01 (6-PIN)
MS3102R10SL-3S
MS3106E10SL-3P
MATING CONN. (REF)
WIRING
A=ANODE
B=TRIGGER
C=CATHODE
-00
-00
-00 ALL
-00
-01
-01
-01 ALL
-01
MS3112E10-6S
CONN. (REF) OR EQUIVALENT MS3116F10-6P
MATING CONN. (REF)
WIRING
A=(ANODE) STROBE LIGHT B=(TRIGGER) STROBE LIGHT C=28VDC(+) POSITION LIGHT D=(CATHODE) STROBE LIGHT E= F=GROUND(-) POSITION LIGHT
Page 2