INSTALLATION INSTRUCTIONS
MODEL MZC-RM
3 ZONE RELAY MODULE
NOTE: All CAUTIONS and WARNINGS are identified by the symbol .
Use this product according to this instruction manual. Please keep this instruction manual for future reference.
APPLICATION INFORMATION:
The MZC-RM is a plug-in relay module designed to allow relay control through the MZC-144 Modular Zone Control. The MZC-RM
provides a fixed zone group consisting of three relay outputs, two Form C and one selectable (normally open or normally closed) dry
contacts. Each of the relay outputs is capable of providing a dry contact, rated at 24VDC at 500mA (resistive load). This device is not intended for high power switching applications.This device is also not intended for security applications. The MZC-RM is
capable of two different modes of operation, non-latching or latching.
The MZC-RM can be plugged into the MZC-144 at three positions. Figure 1 shows the MZC-144 PC Board, and the 3 positions where
the MZC-RM expansion module may be inserted. Chart 1 shows the single zone dial access codes for activation of the MZC-144 and
the three positions available to the MZC-RM.
The MZC-144 activates one relay at a time on the MZC-RM. This is accomplished through the use of the single zone dialing access
codes set forth in Chart 1. Through the use of logical zone groups, the MZC-144 can activate multiple relays during activation of the
MZC-RM. Logical zone groups, which can be up to five entries, are defined by the user. When Logical Zone Groups are programmed
for use by the MZC-RM, only single zone access codes may be used. (For additional information on programming logical zone groups,
see the MZC-144 Installation Instructions (P83259).) Please note the use of fixed zone group paging and/or an All Call page on the
MZC-144 will not be acknowledged by the MZC-RM.
Position 1 77/077 89/089 101/101 113/113 125/125 137/137
78/078 90/090 102/102 114/114 126/126 138/138
79/079 91/091 103/103 115/115 127/127 139/139
Position 2 80/080 92/092 104/104 116/116 128/128 140/140
81/081 93/093 105/105 117/117 129/129 141/141
82/082 94/094 106/106 118/118 130/130 142/142
Position 3 83/083 95/095 107/107 119/119 131/131 143/143
84/084 96/096 108/108 120/120 132/132 144/144
Legend: Zones/Access Code
Example: 7/007 = Zone 7, dial access code 007
*The MZC-RM does not use these single zone dial access codes.
INSTALLATION INSTRUCTIONS:
1. Remove MZC-144 cover.
2. Disconnect power.
3. Select the position which the MZC-RM is to be plugged into from Chart 1 (e.g.: if you want the MZC-RM to be zones 7, 8 or 9 on
the MZC-144, the MZC-RM would be installed in Position 2 on the MZC-144 board).
4. Plug MZC-RM into its selected position (See Figure 1).
CAUTION: Plugging the MZC-RM in backwards can result in improper operation and failure of the unit.
5. Set 2 configuration jumpers in accordance with Figure 2.
6. Connect relay outputs as required (See Figure 2).
7. Re-apply power to unit.
8. Re-install MZC-144 cover.
CAUTION: These devices are not intended for use in hazardous locations as defined by the National Electrical Code (NEC).
P83477 A
Sheet 2 of 4
Figure 2: Installation and Configuration Instructions
E1 Shorting Plug Between Pins
* 1-2: Latching
2-3: Non-Latching
E2 Shorting Plug Between Pins
* 1-2: No Contact
2-3: NC Contact
* Denotes shipped configuration
Limited Warranty
P83477 A
Sheet 3 of 4
Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated,
maintained and operationally tested in accordance with these instructions at the time of installation and at least twice a year or more
often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation,
maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire
Protection Association (NFPA), Underwriters' Laboratories (UL), Underwriters’ Laboratories of Canada (ULC), National Electrical Code
(NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable
building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and
the requirements of the local authority having jurisdiction (AHJ). Wheelock products when properly specified, applied, installed,
operated, maintained and operationally tested as provided above are warranted against mechanical and electrical defects for a period of
three years from date of manufacture (as determined by date code). Correction of defects by repair or replacement shall be at
Wheelock's sole discretion and shall constitute fulfillment of all obligations under this warranty. THE FOREGOING LIMITED
WARRANTY SHALL IMMEDIATELY TERMINATE IN THE EVENT ANY PART NOT FURNISHED BY WHEELOCK IS INSTALLED IN
THE PRODUCT. THE FOREGOING LIMITED WARRANTY SPECIFICALLY EXCLUDES ANY SOFTWARE REQUIRED FOR THE
OPERATION OF OR INCLUDED IN A PRODUCT. WHEELOCK MAKES NO REPRESENTATION OR WARRANTY OF ANY OTHER
KIND, EXPRESS, IMPLIED OR STATUTORY WHETHER AS TO MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE
OR ANY OTHER MATTER.
USERS ARE SOLELY RESPONSIBLE FOR DETERMINING WHETHER A PRODUCT IS SUITABLE FOR THE USER'S PURPOSES,
OR WHETHER IT WILL ACHIEVE THE USER'S INTENDED RESULTS. THERE IS NO WARRANTY AGAINST DAMAGE
RESULTING FROM MISAPPLICATION, IMPROPER SPECIFICATION, ABUSE, ACCIDENT OR OTHER OPERATING CONDITIONS
BEYOND WHEELOCK'S CONTROL.
SOME WHEELOCK PRODUCTS CONTAIN SOFTWARE. WITH RESPECT TO THOSE PRODUCTS, WHEELOCK DOES NOT
WARRANTY THAT THE OPERATION OF THE SOFTWARE WILL BE UNINTERRUPTED OR ERROR-FREE OR THAT THE
SOFTWARE WILL MEET ANY OTHER STANDARD OF PERFORMANCE, OR THAT THE FUNCTIONS OR PERFORMANCE OF
THE SOFTWARE WILL MEET THE USER'S REQUIREMENTS. WHEELOCK SHALL NOT BE LIABLE FOR ANY DELAYS,
BREAKDOWNS, INTERRUPTIONS, LOSS, DESTRUCTION, ALTERATION, OR OTHER PROBLEMS IN THE USE OF A PRODUCT
ARISING OUT OF OR CAUSED BY THE SOFTWARE.
THE LIABILITY OF WHEELOCK ARISING OUT OF THE SUPPLYING OF A PRODUCT, OR ITS USE, WHETHER ON WARRANTIES,
NEGLIGENCE, OR OTHERWISE, SHALL NOT IN ANY CASE EXCEED THE COST OF CORRECTING DEFECTS AS STATED IN
THE LIMITED WARRANTY AND UPON EXPIRATION OF THE WARRANTY PERIOD ALL SUCH LIABILITY SHALL TERMINATE.
WHEELOCK IS NOT LIABLE FOR LABOR COSTS INCURRED IN REMOVAL, REINSTALLATION OR REPAIR OF THE PRODUCT
BY ANYONE OTHER THAN WHEELOCK OR FOR DAMAGE OF ANY TYPE WHATSOEVER, INCLUDING BUT NOT LIMITED TO,
LOSS OF PROFIT OR INCIDENTAL OR CONSEQUENTIAL DAMAGES. THE FOREGOING SHALL CONSTITUTE THE SOLE
REMEDY OF THE PURCHASER AND THE EXCLUSIVE LIABILITY OF WHEELOCK.
IN NO CASE WILL WHEELOCK'S LIABILITY EXCEED THE PURCHASE PRICE PAID FOR A PRODUCT.
Limitation of Liability
WHEELOCK'S LIABILITY ON ANY CLAIM OF ANY KIND, INCLUDING NEGLIGENCE AND BREACH OF WARRANTY, FOR ANY
LOSS OR DAMAGE RESULTING FROM, ARISING OUT OF, OR CONNECTED WITH THIS CONTRACT, OR FROM THE
MANUFACTURE, SALE, DELIVERY, RESALE, REPAIR OR USE OF ANY PRODUCT COVERED BY THIS ORDER SHALL BE
LIMITED TO THE PRICE APPLICABLE TO THE PRODUCT OR PART THEREOF WHICH GIVES RISE TO THE CLAIM.
WHEELOCK'S LIABILITY ON ANY CLAIM OF ANY KIND SHALL CEASE IMMEDIATELY UPON THE INSTALLATION IN THE
PRODUCT OF ANY PART NOT FURNISHED BY WHEELOCK. IN NO EVENT SHALL WHEELOCK BE LIABLE FOR ANY CLAIM OF
ANY KIND UNLESS IT IS PROVEN THAT OUR PRODUCT WAS A DIRECT CAUSE OF SUCH CLAIM. FURTHER, IN NO EVENT,
INCLUDING IN THE CASE OF A CLAIM OF NEGLIGENCE, SHALL WHEELOCK BE LIABLE FOR INCIDENTAL OR
CONSEQUENTIAL DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR
CONSEQUENTIAL DAMAGES, SO THE PRECEDING LIMITATION MAY NOT APPLY TO ALL PURCHASERS.
2/97
P83477 A
Sheet 4 of 4
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.