Wharfedale Pro DP-4035, DP-4100, DP-4065, DP-4120, DP-2200 Operating Manual And User Manual

OPERATINGMANUALANDUSERGUIDE
www.wharfedalepro.com
Professional Power Amplifier
DP SERIES
TABLE OF CONTENTS ..............................................................................1
INTRODUCTION ........................................................................................ 3
ABOUT THE DP SERIES ...........................................................................3
FEATURES ................................................................................................. 3
FRONT PANEL FEATURES AND CONTROLS .......................................... 4
REAR PANEL FEATURES AND CONTROLS ............................................ 5
TABLE OF CONTENTS
1
QUICK START GUIDE ................................................................................ 6
DIMENSIONS ............................................................................................. 7
WIRING DIAGRAMS .................................................................................. 8
POWER CONSUMPTION AND HEAT....................................................... 11
GAIN AN D SENSITIVIT Y............ .......... ... .......... ............. .......... ..1 2
SPECI FICATION.. .......... ... .......... ............. .......... ... .......... ...........13
WHARFEDALE PRO LIMITED WARRANTY..............................................16
2
IMPORTANT WARNINGS & SAFETY INSTRUCTIONS
2. Follow all instructions
3. Keep these instructions
4. Heed all warnings
5. Do not use this apparatus near water
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
9. Do not defeat the safety purpose of a polarised or grounding plug. A polarised plug has two blades with one wider than the other. A grounding plug has two blades and a third grounding blade. The wide blade or the third blade is provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
10.Protect the power cord from being walked on or pinched, particularly at the plug, receptacle and or the point where it exits from the apparatus.
11.Only use attachments/accessories specified by the manufacturer.
12.Only use a stand, tripod, bracket or rack specified by the manufacturer, or sold with the apparatus. When a rack is used, use caution when moving the rack and apparatus combination to avoid tip-over or injury.
13.Unplug the apparatus during lightning storms or when unused for long periods of time.
14. Refer all servicing to qualified personnel. Servicing is required when the apparatus has been damaged in any way including but not limited to power supply cord or plug damage, liquid ingress, foreign objects in the chassis, exposure to rain/moisture or impact damage. In addition the unit must be serviced when you experience any abnormal operation.
15. CAUTION: These servicing instructions are for use by qualified service personnel only. To reduce the risk of electric shock, do
not attempt to perform any servicing other than that contained in the operating instructions unless you are
qualified to do so. In addition opening the casing will result in your warranty becoming null and void.
16. Do not install this apparatus in a confined space such as a book case or similar unit. Good ventilation should be maintained around the apparatus. Any vents, air-inlets or fans should not be obstructed by objects such as paper, table-cloths, curtains etc.
17. WARNING: To reduce the risk of fire or electric shock, do not expose the apparatus to rain or moisture. The apparatus should not be exposed to dripping or splashing and objects filled with liquids, such as vases, should not be placed on the apparatus.
18. WARNING: The mains plug/appliance coupler is used as a disconnect device, the disconnect device shall remain readily operable.
19. The lightning fiash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of non-insulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock.
- Warning: To reduce the risk of electric shock, do not remove the cover (or back) as there are no user-serviceable parts inside. Refer servicing to qualified personnel.
- The exclamation point wi
thin an equilateral triangle is intended to alert the user to the presence of important
operating and maintenance instructions in the literature accompanying the appliance.
20.
(Protective earthing terminal) The apparatus should be connected to a mains socket outlet with a protective
earthing connection.
21. Correct Disposal of this product. This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use local return and collection systems or
contact the retailer where the product was purchased. They
can take this product for safe environmentally friendly recycling.
ATTENTION: RISQUE DE CHOC ELECTRIQUE-NE PAS OUVRIR
1. Read these instructions
3
Congratulations on the purchase of your DP series professional power amplifier. Wharfedale Pro D P amplifiers are the result of many years of experience in the use, design and manufacture of professional audio equipment.
We take great pride in engineering and building every Wharfedale Pro product and wish to thank you for entrusting us with your sound.
From the time Gilbert Briggs built his first loudspeaker in 1932, to the present day, Wharfedale have maintained the same standard of quality in components, workmanship and performance.
Please take the time to read this manual completely in order to ensure that you get the most from your DP power
amplifier.
INTRODUCTION
Suitable for
professional
sound reinforcement or fixed installations, the series feature 5 models that deliver between 760W
and 3400W per channel into a 4 ohm load in a rugged 1U, 19” rack mount enclosure. An advanced switch mode supply and Class D topology deliver high power with low distortion in a compact size and light weight form factor.
A full suite of protection includes thermal, over-current, DC, short circuit protect and power on/off mute. The DP Series features XLR inputs with a maximum input level of +22dBu allowing integration with any t y p i c a l professional audio system. The vari
able speed fans keep the amplifier rack quiet when not in use. The DP series
features
3
different
operating modes, parallel, stereo and brid
g
e
.
ABOUT THE DP SERIES
DP-4035: 595W*4@4Ohms (RMS), 350W*4@8Ohms (RMS), 1190W*2@8Ohms (BTL)
DP-4065: 1100W*4@4Ohms (RMS), 650W*4@8Ohms (RMS), 2200W*2@8Ohms (BTL)
DP-4100: 1700W*4@4Ohms (RMS), 1000W*4@8Ohms (RMS), 3400W*2@8Ohms (BTL)
DP-4120: 2040W*4@4Ohms (RMS), 1200W*4@8Ohms (RMS), 4080W*2@8Ohms (BTL)
DP-2200: 3400W*2@4Ohms (RMS), 2000W*2@8Ohms (RMS), 6800W@8Ohms (BTL)
• XLR inputs
• 3 operation modes ( MONO, STEREO and BRIDGE)
• Power, Protect, Signal and Limiter indicators
Thermal protect, over current protect, DC protect, output short protect
• Ultra quiet variable speed fans
Speakon outputs for speaker
FEATURES
• 1U rack mount chassis
4
Power LED
When t he po wer supply i s wor king the LED is gr een;
Power swi tch
ON/O FF co ntrol. It is O N when “ I” is press ed do wn.
Adjust th e output amp lit ude of the amp lif ier
Volume
PWR
7
4
8
5
6
BTL/ MO NO
Mode
Temp
Temperatu re
When the t emperatu re li miter is activ ated,the LED turns yellow.
When in BT L/M ONO mode the L ED is yellow.
FRONT PANEL FEATURES AND CONTROLS
1 2 3 4 5 6 7 8
illustr ation
functio n
Icon
1
Icon
Protection When there is protection the LED is red.
Faul t
2
Peak
Clip
When the o utp ut signal is d ist orted by mor e tha n 1%
or when
the power i s com press ed, the LED is ye llo w
When the input si gna l is greater t han " -32dB ", the LE D
is gree n;
Signal
3
Signal LE D
Loading...