Page 1: Warning and Safety Instructions
Page 2: Specifications/Operating and Use
Page 3. Product Features/ EVP-X12PM/15PM Panel
Page 4: EVP-X18PB Rear Panel Diagram
Page 5: EVP-X15PB and EVP-X18PB Operation
Page 6: Single EVP-X18PB with Stereo Mid/High Active System and Stereo Active Sub and Mid/High System
Page 7: Stereo Passive Mid/High Speaker with Active Sub System and EVP-X15P/18PB Block Diagram
WARNING & SAFETY INSTRUCTIONS
1. READ INSTRUCTIONS carefully before operating this product.
.
RETAIN these instructions.
2
3. COMPLY WITH WARNINGS - All warnings and instructions for
this product should be adhered to.
4. WATER & MOISTURE - This Wharfedale Pro unit should
not be used near liquids. If should not have liquids placed on or in
close proximity as there are DANGEROUS VOLTAGES
present.
5. VENTILATION/AIR FLOW: This Wharfedale Pro unit
should not have its heat sinks obstructed from air flow. It should
not be situated in a built-in installation that may hamper air flow to
the heat sinks. It should not be placed near heat sources.
6. POWER SUPPLY: This Wharfedale Pro unit should be only
connected to a power supply as stated on the unit. Power supply
cables should be routed where they will not be walked on or
pinched by objects placed adjacent or upon them.
7. ELECTRIC SHOCK: Care should be taken that the grounding
of this unit is NOT defeated. Do not use this units power cable
Wharfedale Pro EVP-XP Series of Professional Sound Reinforcement Loudspeakers
with an extension cable unless the pins can be fully inserted.
7. CABLES - Use quality screened cables for signal connections.
8. RIGGING • SUSPENDING • MOUNTING
The rigging, suspension or mounting of this speaker system can
expose members of the public to serious health risks and even
death. UNDER NO CIRCUMSTANCES ATTEMPT TO RIG,
SUSPEND OR OTHERWISE MOUNT THIS SYSTEM UNLESS
YOU ARE FULLY QUALIFIED AND CERTIFIED TO DO SO BY
RELEVANT LOCAL, STATE AND NATIONAL AUTHORITIES.
ALL RELEVANT SAFETY REGULATIONS MUST BE
FOLLOWED. IF YOU ARE NOT PROPERLY QUALIFIED OR DO
NOT KNOW OF PERTINENT REGULATIONS, CONSULT
QUALIFIED PERSONNEL FOR ADVICE AND ASSISTANCE.
9. CAUTION: These professional loudspeaker systems are
capable of generating very high sound pressure levels. Use care
with placement and operation to avoid exposure to excessive
levels that can cause permanent hearing damage.
10. SERVICING - The user should not attempt to service this
product except that mentioned in this manual.
Unpacking
All Wharfedale Pro products are fully
checked before leaving the factory.
After unpacking please inspect
cabinets for any physical damage.
Please retain the shipping carton if
possible and internal packing material
in case the unit needs to be returned. Please check as soon
as possible the unit is functioning. In the event of any damage
please contact your dealer immediately so that a written claim
for damages can be made.
Wharfedale Pro Limited Warranty*
Wharfedale Pro EVP-XPSeries loudspeaker systems are warranted
to be clear of manufacturing or materials defects for a period of
one year from the original date of purchase. In the event of
malfunction, contact your authorised Wharfedale Professional
dealer or distributor for information.
*Be aware that warranty details may differ from country to
country. Contact your dealer or distributor for information.
These terms do not infringe your statutory rights.
Page 1
WHARFEDALE PRO EVP-XP SERIES
Model NameEVP-X12P EVP-X12PM EVP-X15P EVP-X15PM EVP-X215P EVP-X15PB EVP-X18PB
SYSTEM TYPE 12” 2-way 12” 2 way monitor 15” 2-way 15” 2-way monitor 2x15” 2 way 15” compact sub 18” compact sub
5 band graphic EQ HF Shelving 5 band graphic EQHF ShelvingNANA
Operating/Use
1. The EVP-X12P,X15P,X215P feature 2 x combined jack and XLR inputs.The two stereo inputs are mixed down to mono
enabling the connection of stereo output products.
2. Connect the provided power cable to the IEC mains connector on rear of cabinet.
3 Connect the signal cable (balanced or un balanced, see table and description) from audio mixer or processor securely to
your EVP-XP unit (the internal amplifier should be off, power down mode). Where possible use quality connectors. Only
use screened audio cable for the signal input from the audio mixer or processor. If possible use balanced line signal leads
for optimum quality (see description and table of balanced line operation).
4. If using XLR CONNECTORS, insert the XLR until locked in. If using a jack plug insert until secure.
5. Power up audio mixer or processor ensuring connections are made.
6. Power up EVP-XP internal amplifier with levels on zero. Confirm speakers are operating.
7. The EVP-XP all feature a balanced Male XLR connector on the line output.
8. The EVP-X12PM,X15PM has one speaker extension output allowing the addition of another speaker.
•Integral, preset limiter prevents clipping and distortion. Line-
level stereo inputs are summed before being sent to the
subwoofer’s internal amplifier. This feature allows the subwoofer
to operate in stereo systems using a single subwoofer
A pair of an integral 150Hz, 24dB/Oct crossovers to send a
high-pass, balanced, line-level, stereo signal to a pair of
powered satellite full-range speakers or an external amplifier for
passive satellite speakers.
•A speaker-level, 1/4” TS phone jack is provided. This input is
useful in applications, such as those employing powered
mixers, in which it is more practical to bring a full-range,
speaker-level signal to the subwoofer amplifier
The EVP-X15/18PB is a 15/18 inch direct-radiating powered
subwoofer. A built-in 600 watt (peak) amplifier accepts stereo or
mono line level inputs via balanced, XLR connectors as well as
single channel speaker level input via a 1/4 inch phone jack.
Integral signal processing includes a stereo crossover and
limiting for the internal amplifier. A pair of XLR out-put
5
connectors may be used to pass the input signals to another
system or to send a high-pass, line-level stereo signal to a pair
of powered, full-range speakers.
EVP-X12PM/15PM Panel & Description:
1. Level control: The Level control adjusts the overall volume
of the amplified signal.
2. 5 band EQ: Use this Five-Band Graphic EQ to cut or boost
your signal up to 12dB at designed frequency centers.
This is useful for reducing low frequency rumble or
feedback that often occurs on stage.
3. Parallel Line input and output: These two jacks are
provided to supply a signal input to the EVP-X15PM and to
allow for daisy chaining the signal to possibly another
EVP-X15PM or amplifier combination.
4. Speaker out: The Speaker Out is a post EQ, powered
output designed for speakers with a minimum impedance of
8 ohms speaker. This output should be connected only to
non-powered monitor speakers. The EVP-X15M is the
perfect extension monitor to use in this application.
5. Power switch: use this switch to turn the unit on and off.
6. AC Input connector: The line cord (included) which
provides AC power to the unit. Connect the line cord to
this connector and to a properly grounded AC supply.
Damage to the equipment may occur if an improper line
voltage is used.
NEVER REMOVE OR CUT THE GROUND PIN OF THE
LINE CORD PLUG
7. Fuse: If the fuse should fail, it must be replaced with the
same type and value in order to avoid damage to the
equipment and prevent voiding the warranty.