Wharfedale EVP-15PM, EVP-15PSB, EVP-12P, EVP-15P, EVP-12PM User Manual

4.3 (4)
Wharfedale EVP-15PM, EVP-15PSB, EVP-12P, EVP-15P, EVP-12PM User Manual

E V P - P S E R I E S P O W E R E D L O U D S P E A K E R S

EVP-P SERIES PROFESSIONAL SPEAKER

SYSTEMS USER MANUAL

EVP-12P, EVP-12PM, EVP-15P, EVP-15PM & EVP15PSB.

W ARNING & SAFETY INSTRUCTIONS

1. READ INSTRUCTIONS carefully before operating this product.

with an extension cable unless the pins can be fully inserted.

2. RETAIN these instructions.

7. CABLES - Use quality screened cables for signal connections.

3. COMPLY WITH WARNINGS - All warnings and instructions for

8. RIGGING • SUSPENDING • MOUNTING

this product should be adhered to.

The rigging, suspension or mounting of this speaker system can

4. WATER & MOISTURE - This Wharfedale Pro unit should

expose members of the public to serious health risks and even

not be used near liquids. If should not have liquids placed on or

death. UNDER NO CIRCUMSTANCES ATTEMPT TO RIG, SUS-

PEND OR OTHERWISE MOUNT THIS SYSTEM UNLESS YOU

in close proximity as there are DANGEROUS VOLTAGES

ARE FULLY QUALIFIED AND CERTIFIED TO DO SO BY RELE-

present.

VANT LOCAL, STATE AND NATIONAL AUTHORITIES. ALL

5. VENTILATION/AIR FLOW: This Wharfedale Pro unit

RELEVANT SAFETY REGULATIONS MUST BE FOLLOWED. IF

should not have its heat sinks obstructed from air flow. It should

YOU ARE NOT PROPERLY QUALIFIED OR DO NOT KNOW OF

not be situated in a built-in installation that may hamper air flow to

PERTINENT REGULATIONS, CONSULT QUALIFIED PERSON-

the heat sinks. It should not be placed near heat sources.

NEL FOR ADVICE AND ASSISTANCE.

6. POWER SUPPLY: This Wharfedale Pro unit should be

9. CAUTION: These professional loudspeaker systems are

only connected to a power supply as stated on the unit. Power

capable of generating very high sound pressure levels. Use care

supply cables should be routed where they will not be walked on

with placement and operation to avoid exposure to excessive lev-

or pinched by objects placed adjacent or upon them.

els that can cause permanent hearing damage.

7. ELECTRIC SHOCK: Care should be taken that the ground-

10. SERVICING - The user should not attempt to service this

product except that mentioned in this manual.

ing of this unit is NOT defeated. Do not use this units power cable

 

Wharfedale Pro EVP-P Series of Professional Sound Reinforcement Loudspeakers

● 200W RMS/320W Peak amplifier

● Hi/Low EQ control in the master section

(EVP 12P,12PM,15P,15PM)

● Integral tripod stand adaptor (except monitors)

 

● 300W RMS/480W Peak in EVP-15PSB only

● Balanced line output

 

● Built in 2 channel mixer with line and mic inputs

● Combined Jack and XLR balanced input connectors

 

● Durable black carpet finish

● Power on/off LED on front and back of unit

 

● Integral High Frequency Driver Overload protection

● Linkwitz Riley crossover for vocal clarity

“PRO-TECH” TM

● Heavy duty steel grille

● HF protection bulb

● Constant directivity HF horn

● Thermal overload, DC fault and short circuit protection

● 2 way trapezoidal ultra compact bass reflex design

● Active crossover (EVP-15PSB only)

 

Unpacking

All Wharfedale Pro products are fully checked before leaving the factory. After unpacking please inspect cabinets for any physical damage. Please retain the shipping carton if possible and internal packing material in case the unit needs to be

returned. Please check as soon as possible the unit is functioning. In the event of any damage please contact your dealer immediately so that a written claim for damages can be made.

Wharfedale Pro Limited Warranty*

Wharfedale Pro EVP-P Series loudspeaker systems are warranted to be clear of manufacturing or materials defects for a period of one year from the original date of purchase. In the event of malfunction, contact your authorised Wharfedale Professional dealer or distributor for information.

*Be aware that warranty details may differ from country to country. Contact your dealer or distributor for information. These terms do not infringe your statutory rights.

Operating/Use

1.The EVP-P series has 2 XLR 1/4” jack Combi sockets.The two stereo inputs are mixed down to mono enabling the connection of stereo output products.

2.Connect the provided power cable to the IEC mains connector on rear of cabinet.

3 Connect the signal cable (balanced or un balanced, see table and description) from audio mixer or processor securely to your EVP-P unit (the internal amplifier should be off, power down mode). Where possible use quality connectors. Only use screened audio cable for the signal input from the audio mixer or processor. If possible use balanced line signal leads for optimum

quality (see description and table of balanced line operation).

3.If using XLR CONNECTORS, insert the XLR until locked in. If using a jack plug insert until secure.

4.Power up audio mixer or processor ensuring connections are made.

5.Power up EVP-P internal amplifier with levels on zero. Confirm EVP-P speakers are operating.

6.The EVP-15PSB has 2 XLR/1/4” Jack Combi Sockets - one line in, for system input and one line out for EVP-P as main speakers. Two main loudspeakers may also be linked to one subwoofer.

Loading...