Wharfedale CPD 1000 User Manual [de,en]

Page 1
CPD SERIES
Professional Power Amplier
OPERATING MANUAL AND USER GUIDE
www.wharfedalepro.com
Page 2
1
TABLE OF CONTENTS
TABLE OF CONTENTS .............................................................................1
IMPORTANT WARNINGS & SAFETY INSTRUCTIONS ........................... 2
REAR PANEL FEATURES AND CONTROLS ...........................................4
OPERATING MODE SWITCHES .............................................................. 5
QUICK START GUIDE ..............................................................................5
DIMENSIONS ............................................................................................6
WARRANTY ............................................................................................1
0
Page 3
IMPORTANT WARNINGS & SAFETY INSTRUCTIONS
1. Read these instructions
2. Follow all instructions
3. Keep these instructions
4. Heed all warnings
5. Do not use this apparatus near water
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including ampliers)
that produce heat.
9. Do not defeat the safety purpose of a polarised or grounding plug. A polarised plug has two blades with one wider than the other. A grounding plug has two blades and a third grounding blade. The wide blade or the third blade is
provided for your safety. If the provided plug does not t into your outlet, consult an electrician for replacement of the
obsolete outlet.
0.Protect the power cord from being walked on or pinched, particularly at the plug, receptacle and or the point where it
1
exits from the apparatus.
11.Only use attachments/accessories specied by the manufacturer.
12.Only use a stand, tripod, bracket or rack specied by the manufacturer, or sold with the apparatus. When a rack is
used, use caution when moving the rack and apparatus combination to avoid tip-over or injury.
3.Unplug the apparatus during lightning storms or when unused for long periods of time.
1
14. Refer all servicing to qualied personnel. Servicing is required when the apparatus has been damaged in any way
including but not limited to power supply cord or plug damage, liquid ingress, foreign objects in the chassis, exposure to rain/moisture or impact damage. In addition the unit must be serviced when you experience any abnormal operation.
CAUTION: These servicing instructions are for use by qualied service personnel only. To reduce the risk of electric
15.
shock, do not attempt to perform any servicing other than that contained in the operating instructions unless you are
qualied to do so. In addition opening the casing will result in your warranty becoming null and void.
6. Do not install this apparatus in a confined space such as a book case or similar unit. Good ventilation should be
1
maintained around the apparatus. Any vents, air-inlets or fans should not be obstructed by objects such as paper, table-cloths, curtains etc.
WARNING: To reduce the risk of re or electric shock, do not expose the apparatus to rain or moisture. The apparatus
17. should not be exposed to dripping or splashing and objects lled with liquids, such as vases, should not be placed on
the apparatus.
8. WARNING: The mains plug/appliance coupler is used as a disconnect device, the disconnect device shall remain
1
readily operable.
The lightning ash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of
19. non-insulated “dangerous voltage” within the product’s enclosure that may be of sufcient magnitude to constitute a
risk of electric shock.
Warning: To reduce the risk of electric shock, do not remove the cover (or back) as there are no user-serviceable
­parts inside. Refer servicing to qualied personnel.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important
­operating and maintenance instructions in the literature accompanying the appliance.
(Protective earthing terminal) The apparatus should be connected to a mains socket outlet with a protective
20.
earthing connection.
1. Correct Disposal of this product. This marking indicates that this product should not be disposed with other
2
household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use local return and collection systems or contact the retailer where the product was purchased. They can take this product for safe environmentally friendly recycling.
ATTENTION: RISQUE DE CHOC ELECTRIQUE-NE PAS OUVRIR
2
Page 4
3
INTRODUCTION
Congratulations on the purchase of your CPD series professional power amplier. Wharfedale Pro CPD ampliers are
the result of many years of experience in the use, design and manufacture of professional audio equipment. We take great pride in engineering and building every Wharfedale Pro product and wish to thank you for entrusting us
with your sound.
From the time Gilbert Briggs built his rst loudspeaker in 1932, to the present day, Wharfedale have maintained the same
standard of quality in components, workmanship and performance. Please take the time to read this manual completely in order to ensure that you get the most from your CPD power
amplier.
ABOUT THE CPD SERIES
Suitable for portable sound reinforcement or xed installations, the series feature 4 models that deliver between 350W
and 1300W per channel into a 4 ohm load in a rugged 2U, 19” rack mount enclosure. An advanced transformer power supply and Class AB/H topology deliver high power with low distortion in a compact and light weight form factor.
A full suite of protection includes thermal, over-current, DC, short circuit protect and power on/off mute. The CPD Series features XLR inputs and linked outputs with a maximum input level of +22dBu allowing integration with any typical professional audio system. The variable speed fans keep the amplifier rack quiet when not in use. The CPD series features 3 different operating modes, parallel, stereo and bridge.
FEATURES
• CPD1000: 350W*2@4Ohms (RMS), 230W*2@8Ohms (RMS), 1000W@4Ohms (BTL)
CPD1600: 620W*2@4Ohms (RMS), 400W*2@8Ohms (RMS), 1600W@4Ohms (BTL)
CPD2600: 1000W*2@4Ohms (RMS), 650W*2@8Ohms (RMS), 2600W@4Ohms (BTL)
CPD3600: 1300W*2@4Ohms (RMS), 870W*2@8Ohms (RMS), 3600W@4Ohms (BTL)
• 2 channels XLR inputs with link outputs
• 3 operation modes (PARALLEL, STEREO and BRIDGE)
• Power, Protect, Signal and Limiter indicators
• Thermal protect, over current protect, DC protect, output short protect, power on/off mute
• Ultra quiet variable speed fans
• Speakon outputs for speakers
• 2U rack mount chassis
Page 5
FRONT PANEL FEATURES AND CONTROLS
1 2 3 4 5
1. LIMITER LED: Illuminates when the amplier is being driven into clipping.
2. SIGNAL LED: Indicates presence of signal on the channel.
3. PROTECT LED: Illuminates when the amplier is in protect mode due to short circuit, over current or thermal overload.
4. POWER LED: Illuminates when the amplier is connected to mains power and switched on.
5. Input Trim: Controls the output level of the amplier.
6. Power switch: To power the amplier up or down.
7. Air lter: Knocked down air lter cover. Easily for clean. The air ow is from front to back.
6
7
REAR PANEL – FEATURES AND CONTROLS
21 3 4 5 6 7 8
1. XLR Input: Balanced XLR input for connection to 0dBu line level sources. CH1 INPUT is also the available input
channel for BRIDGE mode.
2. XLR link Output: Balanced XLR output to another CPD amplier.
3. Mode Switch: There are 3 switchable operating modes, parallel, stereo and bridge.
4. LIMITER Switch: The internal limiter can prevent signal overload and distortion.
5. SPEAKON Output: For connection to passive loudspeakers.
6. Grounding Terminal: The grounding terminal for the chassis.
7. Mains Power Cord: The unit has a xed power cord, and for the safety, this cord is not allowed to be replaced arbitrarily
by the user.
WARNING: DO NOT ATTEMPT TO BYPSS THE GROUND CONNECTION OF THE POWER CORD!
8. FUSE: Please use the same type fuse as the text of the chassis for replacing.
4
Page 6
5
OPERATING MODE SWITCHES
There are 3 different operating modes switchable for the CPD
series ampliers.
STEREO - Each channel remains independent. The amplifier may be used for two different signals. PARALLEL - This setting connects both inputs together. One signal feeds both channels. Each channel's Gain control and loudspeaker connection remain independent. BRIDGE - This setting combines both channels into a single
channel with twice the output power. Use only the rst channel's
input and Gain control. Set the second channel's Gain control at maximum. The load must be rated for the higher output power.
OUTPUT WIRING
The CPD Series employ Speakon output connectors. Ensure that only heavy gauge two conductor speaker cables with professionally wired Speakon connectors are used for
connection from amplier to loudspeaker.
STEREO and PARALLEL Mode- Connect each loudspeaker to
its own channel of the amplier, as shown on the left side of the
Speakon. The Mode switches must be set for Stereo or Parallel Mode. BRIDGE Mode- Bridge Mode configures the channel pair to drive a single audio circuit. The Mode switches must be set for B
ridge Mode. Connect the load as shown on the left side of CH 1’s
Speakon.
WARNING: Do not use less than 4 ohm load in Bridge Mode! WARNING: Note polarity of connection for Bridge Mode. OUTPUT WIRING WARNING: Class 2 wiring shall be used. For Bridge Mode, class 3 wiring shall be used. OUTPUT SAFETY WARNING: Make all connections with
amplier turned off. Risk of hazardous energy!
CH 1
CH 2
STEREO/ PARALLEL
+=Positive
1 1-=Negative
1
+=Positive
1-=Negative
BRIDGE
1+=Positive 2+=Negative
No use
QUICK START GUIDE
1. Make sure that the power switch is set at the OFF position while making connections to and from the power amplier.
2. Connect all devices in the signal path and ensure that each connection is secure.
3. Set all level and gain controls to their minimum.
4. After powering up all other devices rst, turn on the CPD amplier and verify that the POWER LED is illuminated.
5. Turn the amplier volume control up to the 3 o'clock position. (This setting can be adjusted higher or lower, as needed,
after set-up). With source signal present starts to set each gain stage in your signal path, starting at the beginning of
the chain. It is best practice to make overall volume changes with the master fader of your mixing console once the
amplier input trim has been calibrated.
6. When powering down, make sure that the power ampliers are switched off rst.
Page 7
DIMENSIONS
6
Page 8
7
WIRING DIAGRAM
Page 9
SPECIFICATION
Model Name CPD1000 CPD1600
Stereo Power Output 8 ohms*2 230W 400W 4 ohms*2 350W 620W Bridged Mono Output 8 ohms 700W 1 4 ohms 1 Input Sensitivity & impedance Sensitivity 0dBu (0.775Vrms) 0dBu (0.775Vrms) Balanced XLR input 20Kohms 20Kohms Maximum Input Level 22dBu (9.7Vrms) 22dBu (9.7Vrms) Voltage Gain 35dB 37dB Slew Rate >40V / us >40V / us Crosstalk <-70dB <-70dB S/N > Distortion (1W) <0.02% <0.02% Frequency Response +/-1dB @ 8 Ohmes 20Hz - 20KHz 20Hz - 20KHz +/-3dB @ 8 Ohmes 20Hz - 30KHz 20Hz - 30KHz Damping Factor >300 >300 Topology Class AB Class AB Connectors Signal Input and Output Female and Male XLR Jacks Female and Male XLR Jacks Power Output SPEAKON Jacks SPEAKON Jacks Controls Front panel AC Switch, CH Rear panel Parallel, Stereo & Bridge Mode Switch; Limiter Switch
000W 1600W
100dB >100dB
1 and CH 2 Gain Knobs
200W
Protections
Indictors Power, Protect, Signal, Limiter Cooling Variable Speed Fan
AC Power Options
Dimensions 88*483*330mm 88*483*330mm Carton Box Weight (Net) 1 Weight (Gross) 1
Thermal protect, Over-current protect, Output DC protect, Output short protect, Power on/off mute
A
C110-120V~ 50/60Hz or AC100V~ 50/60Hz;
AC220-230V~ 50/60Hz or AC240V~ 50/60Hz
1kg 13kg
2.5kg 14.5kg
8
A
C110-120V~ 50/60Hz or AC100V~ 50/60Hz;
AC220-230V~ 50/60Hz or AC240V~ 50/60Hz
Page 10
9
SPECIFICATION
Model Name CPD2600 CPD3600
Stereo Power Output 8 ohms*2 650W 870W 4 ohms*2 1 Bridged Mono Output 8 ohms 1 4 ohms 2600W 3600W Input Sensitivity & impedance Sensitivity 0dBu (0.775Vrms) 0dBu (0.775Vrms) Balanced XLR input 20Kohms 20Kohms Maximum Input Level 22dBu (9.7Vrms) 22dBu (9.7Vrms) Voltage Gain 39dB 4 Slew Rate >40V / us >40V / us Crosstalk <-70dB <-70dB S/N > Distortion (1W) <0.02% <0.02% Frequency Response +/-1dB @ 8 Ohmes 20Hz - 20KHz 20Hz - 20KHz +/-3dB @ 8 Ohmes 20Hz - 30KHz 20Hz - 30KHz Damping Factor >300 >300 Topology Class H Class H Connectors Signal Input and Output Female and Male XLR Jacks Female and Male XLR Jacks Power Output SPEAKON Jacks SPEAKON Jacks Controls Front panel AC Switch, CH Rear panel Parallel, Stereo & Bridge Mode Switch; Limiter Switch
000W 1300W
940W 2590W
1dB
100dB >100dB
1 and CH 2 Gain Knobs
Protections
Indictors Power, Protect, Signal, Limiter Cooling Variable Speed Fan
AC Power Options
Dimensions 88*483*450mm 88*483*450mm Carton Box Weight (Net) 1 Weight (Gross) 22.5kg 25.5kg
Thermal protect, Over-current protect, Output DC protect, Output short protect, Power on/off mute
A
C110-120V~ 50/60Hz or AC100V~ 50/60Hz;
AC220-230V~ 50/60Hz or AC240V~ 50/60Hz
9kg 22kg
AC220-230V~ 50/60Hz or AC240V~ 50/60Hz
Page 11
WHARFEDALE PRO LIMITED WARRANTY
Wharfedale Pro products are warranted of manufacturing or material defects for a period of one year from the original date of purchase. In the event of malfunction, contact your authorized Wharfedale Pro dealer or distributor for information.
*Be aware that warranty details may differ from country to country. Contact your dealer or
distributor for information. These terms do not infringe your statutory rights.
10
Page 12
Wharfedale Professional
IAG House, 13/14 Glebe Road, Huntingdon, Cambridgeshire, PE29 7DL, UK
www.wharfedalepro.com
Wharfedale Professional reserves the right to alter or improve specications without notice.
All rights reserved © 2014 Wharfedale Pro. Wharfedale Pro is a member of the IAG Group.
Loading...