CONTENTS
1. Principles of Operation
2. Specifi cation
3. Application
4. Warnings
5. Parts List
6. Instructions for Installation
7. Maintenance
8. Trouble Shooting
9. Winterising
10. Service Support Details
11. EU Declaration of Conformity
12. Patents and Trademarks
13.Warranty
UF2014 / UF2015 / UF2025 / UF8025
Read the following carefully before installation
To the Fitter:
Check that the product is suitable for the intended application. Follow these installation instructions and ensure all
relevant personnel read the points listed below. Also ensure that these operating instructions are passed on to the end
user. The manufacturer cannot be held responsible for claims arising from incorrect installation, unauthorised
modifi cation or misuse of the product.
To the User:
Read the following instructions carefully.
Page 2
1. PRINCIPLES OF OPERATION
The function of a pump accumulator kit is to provide smooth fl ow from the system with reduced pump cycling.
2. SPECIFICATION
Product CodeUF2014UF2015UF2025UF8015UF8025
Pressure Pump
Flow Rate
Voltage12 V d.c.24 V d.c.12 V d.c.24 V d.c.
Cut out Pressure2 bar / 30 psi3 bar / 45 psi
Accumulator Tank
Size
Weight
(non operational)
Factory Pre-charge
Pressure +/-0.14
bar +/- 2psi
Inlet Size
Outlet Size
Hose Connection
(Inlet)
Universal
(UF1214)
1.5 bar / 22psi2.2 bar / 32psi
Universal
(UF1215)
11.5ltrs/min
(3.0 US Gals/min)
5.4kg / 11.9lbs
Whale® Quick Connect 15mm Female Connections
For ½” Flexible hose use WX1584 Stem Adaptor
Universal
(UF1225)
8ltrs / 2.2 US Gals
or WX1591 Stem Elbow
Universal
(UF1815)
(4.75 US Gals/min)
5.9kg / 13.0lbs
Universal
(UF1825)
18ltrs/min
Materials in contact
with liquid
Minimum Wire Size2.5mm2 (13 AWG)
Maximum Head20m (66ft)30m (98ft)
Maximum Lift3m (10ft)
Recommended
The Whale® Accumulator kit is designed for installation in recreational marine vessels for saltwater or freshwater use,
with 12 V d.c. or 24 V d.c. electrical supply only. If it is intended for use for any other purpose or with any other liquid, it
is the user’s responsibility to ensure that the pump is suitable for the intended use and, in particular, that the materials
are fully compatible with the liquids to be used.
4. WARNINGS
1. This pump is designed for supplying water in a marine vessel. If it is intended for use for use for any other
purpose it is the user’s responsibility to ensure that the pump is suitable for the intended use.
2. Not suitable for pumping fl ammable liquids, diesel, chemicals etc. Only suitable for freshwater and saltwater.
3. A Whale® strainer must befi tted on the inlet side of the pump to prevent any dirt/debris entering the pump
4. With all applications, it is important that a system of safe working practice is applied to installation, use and
maintenance. Ensure the electrical supply is turned off and water system is drained before installation. In
order to securely fasten the unit, ensure that the mounting surface is a minimum thickness of 19mm (3/4”)
when fi tted.
5. NOTE: Do not screw directly into the hull. Must be mounted on a bulkhead or additional board.
6. CAUTION: Pump not intended for continuous use
7. WARNING: Fire hazard. Wiring must comply with applicable electrical standards and include a properly
sized fuse or circuit breaker. Improper wiring can cause a fi re resulting in injury or death. Switch off the power while making connections. Suggested wiring information is given as guidance only. For full information, refer
to the USCG, ABYC and ISO regulations for marine applications and wiring gauges, connectors and fuse
protection.
5. INSTRUCTIONS FOR INSTALLATION
The following guidelines should be followed to achieve optimum pump performance.
MOUNTING LOCATION
1. Locate in a dry position, free of submersion and spray, with adequate ventilation, no more than 3 metres
above the water tank.
2. The kit can be mounted horizontally or vertically (we recommend the pump head is below motor level).
3. We recommend the kit is secured using nuts and bolts or stainless steel screws. (Washers must be used.)
Typical Installation
ELECTRICAL
1. Use specifi ed fuse, as indicated on motor label, in the circuit.
2. Connect red wire to positive and black wire to negative - recommended wire size should be (2.5mm²).
3. Fit an adequate isolating switch on the positive side of the supply.
4. To prevent the pump running continuously, turn off at isolating switch when boat/caravan/R.V is left
unattended or water supply has been allowed to empty.
Page 4
PLUMBING
1. Installation of an easy-clean fi lter/strainer is recommended. Always attach strainer to inlet side of pump.
2. Check pump fl ow direction (as indicated on pump body).
3. Never use pipe sealant or sealing tapes on the threads. These may enter the pump and cause failure.
If water is allowed to freeze in the system, serious damage to the pipework and pump may occur. To best avoid this
damage, completely drain the water system.
6. MAINTENANCE
Periodic check of the complete water system by a professional installer is recommended at least once a year. During
such a check, the precharge of the tank should be verifi ed and adjusted if required
7. TROUBLE SHOOTING
FaultCauseSolution
Pump doesn’t run.No power to the pump.
Fuse has blown.
Pump runs but no water
appears.
Water leak.
Pump runs but will not
switch off.
Pump cycles on/off
periodically when all
taps are closed.
(Normal with partially
opened tap)
Pump cycles on & off
excessively when tap/s
are open.
Blockage in pipework
No water getting to pump.
Pipework leaks at outlet
side of pump.
Water leaks at outlet side.
No water.
Air getting into system.
Water leaks at outlet side.
Excessive dirt in the
system
Excessive back pressure
between pump and
accumulator tank.
Incorrect tank pre-charge
pressure.
Check pipework for kinks & fi lters etc. are clear.
Check water supply level.
Check strainer is clear.
Check pipework/fi ttings for leaks & repair.
Check pipework & fi ttings for leaks & repair.
Check system bleed valve/s are closed.
Check pipework/fi ttings for leaks & repair.
Check taps/shower for leaks & repair.
Check water supply level.
Check pipework/fi ttings (on supply side) for leaks & repair.
Check pipework/fi ttings for leaks & repair.
Check taps/shower for leaks & repair.
Ensure fi lter is fi tted to inlet of pump. Run pump
continuously for 5 minutes with all outlets and valves
open.
Check connections for blockage and repair.
Turn power off - release all pressure in system.
Check pre-charge is at recommended level.
Noisy operation.Pump drawing air.
Noise created by vibration.
8. WINTERISATION
1. Drain the water tank either using the pump or a drain valve.
2. Open all the faucets (including drain valve) and allow pump to purge the water from the system, then turn the
pump off.
3. Disconnect the pump kit and turn on to purge into an adequate basin. Only connect pump kit again when it is
to be used.
4. Remember to leave all faucets including showers open to avoid any damage.
9. SERVICE SUPPORT DETAILS
For installation or service advice please contact Whale® Customer Support:
Tel: +44 (0)28 9127 0531
Email: info@whalepumps.com
www.whalepumps.com
Check pipework/fi ttings (on supply side) for leaks & repair.
Check pump is secured to solid surface.
Check pump body is clear of hard surfaces. Locate away
from interferring surfaces.
Check pipework is securely supported.
Page 5
10. EU DECLARATION OF CONFORMITY
We hereby declare, under our sole responsibility, that the enclosed equipment complies with the provisions of the
following EC Directives.
Electromagnetic Compatibility Directive 2004/108/EC on the approximation of the laws of the Member States relating
to electromagnetic compatibility.
CE mark affi xed: March 2014
Basis on which conformity is declared - The above equipment complies with the protection requirements of the EMC
Directive.
Standards applied
94/25/EC amending 2003/44/EC Recreational Craft Directive
ISO10133:2000 Extra-low voltage DC Installation
EN55014-1:2006 EMC Emissions
EN55014-2:1997+A2:2008 EMC Immunity
EN28846 :1993 Ignition Protection
ABYC-H23 Installation of Potable Water
Richard Bovill
Engineering Director
11. PATENTS AND TRADEMARKS
WHALE® and GUSHER® are registered trademarks of Munster Simms Engineering Limited, Bangor, Northern Ireland
trading as Whale.
12. WARRANTY
This Whale® product is covered by a 2 year warranty. Please see the enclosed document for details of our
Statement of Limited Warranty.
Periodic check of the complete water system by a professional installer is recommended at least once a year. During
such a check, the precharge of the tank should be verifi ed and adjusted if required.
Neither the accuracy nor completeness of the information contained in any Product brochure is guaranteed by the
Company and may be subject to change at its sole discretion.
Please note that by contacting Whale Support you will be indicating your consent to receiving product updates, recall