Gulper Toilet Pump
Ensure all relevant personnel read the points listed below and that a copy is passed on to the end user.
Read the points listed below before installation and use of equipment.
The Whale Gulper Toilet pump is designed to pump macerated and non-macerated toilet waste without blocking. It offers a reliable means of emptying waste holding tanks overboard and may be used in vacuum toilet systems.
Ensure pump inlet and outlet valves are assembled in correct orientation (Fig.1). Check that valves are properly seated and inner and outer valve housings are tightened fully.
1. Mount the pump above the level of the holding tank. If this is not possible, fit a service valve on the holding tank side of the pump. This prevents waste draining into the pump during maintenance.
2. Mount the pump horizontally.
3. Direction of flow can easily be altered by loosen­ing the screws which hold the clamping rings. Rotate the pump head to the required angle, check direction of flow and re-tighten (Fig.2).
Note:
a) The pump is designed to work at a maximum lift/head combination of 3m (10ft). This includes height of pump above holding tank outlet and distances from pump to the highest point in the discharge line and distance of seacock discharge below waterline. b) As the holding tanks on most boats are installed below the waterline it is essential that proper siphon breaks (vented loops) are installed to prevent siphon­ing water into the toilet by leakage past the suction or discharge valves of the pump.
4. A typical installation is shown in (Fig.3).
5. Position the pump in a dry, ventilated area that allows maintenance access. Fix the pump in position by attaching the screws and washers provid­ed through the rubber feet.
1. It is recommended to use 38mm
(11/
2
") smooth
bore thick walled non-collapsing hose which is designed to minimise the permeation of waste system odours.
2. To reduce the likelihood of permeation of odours, keep the hose runs as short and as straight as possible. Avoid dips in the hose which will remain “wet”. Sweep connections instead of elbows should be used whenever possible.
3. Connect the inlet and outlet hose to the pump ensuring the flow direction is correct (Fig.1). Two stainless steel hose clamps should be used at each connection.
4. Where appropriate the Whale Diverter Valve (DV5606), which has been specifically designed to handle toilet waste should be used.
5. Install seacocks, deck fittings, etc. as per manufacturers recommendations.
6. Do not connect pump directly in line with a deck pumpout fitting.
Note:
An in-line fuse assembly is already fitted. This is to prevent serious damage in the event of system blockages. Ensure valves, seacocks etc. are fully open before operating the pump.
1. Use recommended replacement fuse and correct wire size (see specifications).
2. Connections for a typical holding tank pump out system are shown inn Fig.4.
3. Connect the power cable to the spade terminals on the pump using crimped on connectors. Note: the pump is polarity sensitive and will not operate if connected wrongly. Protect the cable where it runs through holes or over sharp edges.
4. Wiring must comply with applicable electrical standards.
1. The pump is rated for up to 40 minutes continuous running. Warning:- Pump motor casing can become hot. Avoid prolonged contact.
2. Always fit correct fuse.
3. Unnecessary running will reduce the life of the valves and diaphragm. Turn off the pump when leaving the boat. If some power has to be maintained install a dedicated pump switch (Fig.5).
4. Ensure valves are seacocks are open before operating pump.
5. Do not flush paper towels or feminine hygiene
Electrical Connections
Assembly
Application
To the User
To the Fitter
Plumbing
Installation
Operation
Page 2
products. Keep paper usage to a minimum.
6. Ensure system is properly vented. To prevent odours, run vent lines from siphon breaks to vent fit­tings above maximum heeled water line.
7. Keep pump manufacturer’s recommended spares kit on board (also toilet system spares).
Pump
1. Isolate power to pump and close service valve, if fitted before dismantling pump. Place a drip tray below pump head and inlet and out­let hoses during maintenance.
Valve Replacement/Inspection
1. Disconnect the inlet and outlet hoses and unscrew outer and inner valve housings to give access to the valves.
2. The valves should be flexible and the opening silt should be closed to its relaxed state. Trapped debris in the valves or valve housings should be removed.
3. When refitting ensure the valves are assembled in the correct orientation (Fig.1).
Diaphragm Replacement/Inspections
1. Remove the pump head clamping rings by unscrewing the two clamping screws which will release the pump head and allow easy access to the diaphragm.
2. To replace/inspect diaphragm it is not necessary to disassemble valves. This will minimise spillage.
3. Remove diaphragm by undoing 8mm locking nut holding diaphragm plate against diaphragm and crank arm.
4. When re-assembling ensure that the outer edge of the diaphragm is located securely in the grooves between the body and the gear housing. Failure to do so will cause priming/vacuum creation problems.
5. It is important that the diaphragm plate is assem­bled with the rounded edge towards the diaphragm.
6. Refit the locking nut and clamping ring and tighten screws.
1. Periodically check all connection clamps for slack and corrosion and replace as necessary.
2. Use toilet cleaners made specifically for marine toilets. DO NOT USE bleach or drain cleaner. Rinse and flush the holding tank after each pump out. This will dilute any residual waste, and help prevent blockage and reduce odours.
3. Properly winterize the toilet system. As a rule it is best to leave the system completely drained and dry.
Pump operates but no waste pumped ? Check:
a) all connections are airtight and secure. b) seacocks/valves are open. c) clamping ring screws are tight and diaphragm fit­ted correctly. d) diaphragm/valves do not need replacement.
Pump will not operate? Check: a) electrical connections / fuse. If fuse blows check for closed valves and blocked pipes. b) correct polarity connections to pump.
Spares Kit Part No: AK1557. Any questions contact our service desk ­Email: support@whalepumps.com.
This Whale product is covered by 1 years warranty. Please see the enclosed document for details of our statement of limited warranty.
We hereby declare that the Gulper 220 conforms with the provisions of the following EC Directives: Electromagnetic Compatibility Directive 89/336/EEC, amended by 92/31/EEC and 93/68/EEC on the approximation of the laws of the member states.
CE mark affixed 26/06/06
Basis on which conformity is declared. The Gulper 220 complies with the protection requirements of the EMC Directive.
Standards applied EN55014-12000 and EN55014-2:1997.
Signed:
David Cresswell
Position: Engineering Director
Fault Finding
Maintenance
General
Warranty
Service Kits
Declaration of Conformity
Page 3
Valves Pump
Valves
Fig.2 Altering Flow Direction
Loosen clamping ring screws
Fig.4 Electrical Connections
Fig.1 Pump Head
Fig.4 Typical Pumpout Installation
Page 4
Munster Simms Engineering Ltd.
Old Belfast Road, Bangor, N. Ireland BT19 1LT Tel: +44 (0)28 9127 0531 Fax: +44 (0)28 9146 6421
Web: www.whalepumps.com Email: info@whalepumps.com
Ref No. 180.62_v2_0410
Gulper Toilet Pump Specifications
Product Code BP2552B BP2554B
Voltage 12V d.c. 24V d.c.DC
Recommended Fuse Size 10 amp automotive 5 amp automotive
Weight
2.12kg (43/4lbs)
Open Flow Rate Per Minute
18ltrs (43/4US gals)
Hose Conenctions
38mm (11/2”)
Minimum Wire Size
1.5mm2 (16AWG)
Materials
Glass filled nylon, bronze, EPDM, Nitrile, Hypalon, Acetal,
stainless steel, brass, aluminium.
Maximum Head 3m (9.8ft)
Maximum Lift 3m (9.8ft)
Maximum Head & Lift 3m (9.8ft)
Dry Running Current 4amps 2amps
Vacuum Capacity 30mm (12”) of mercury
Noise 72db
Ignition Protected to ISO8846