Page 1
Bilge Accessories
Bilge Accessories
Complete Your System
Fit Whale®high quality pumps and accessories to ensure long term reliability throughout your bilge waste system. Whale switches, diverter valves, and pipework connections are designed and manufactured with highest quality at heart. Combine these accessories with your Whale bilge pumps for reliability and durability.
Need specific advice on your system? Contact our technical team at Whale Support
See below for a full list of accessories
Easy wiring
- two colour coded wires
Electric Bilge Switches
NEW Electric Field Sensor Range
• Electric field sensor automatically senses water levels and switches on the bilge pumps
• Nylon material - withstands high temperatures
• BE9006 model - built in 30 second off delay for efficient operation, prevents cycle in small sump installations or enables lower drain than 13mm (
Model Specifications
Model Electric Field Sensor Switch Electric Field Sensor Switch
Product Number BE9003 BE9006
Voltage D.C. 12V d.c. or 24V d.c.
Current Suitable for up to 20 Amps
Residual Current 0.008 Amp
Suitable for Orca and Supersub standard submersible ranges – pages 26 and 28
with 30 second time delay
1
/2”)
for easy installation
Easy installations
- side or base mounting
ears to suit your installation
BE9003 / BE9006
Testing
- two test circle to ensure activation
Float Switch
Floatswitch Ideal for use with Electric Bilge Pumps
• Environmentally friendly - no toxic mercury
• Easy to install mounted on either horizontal or vertical surface (e.g. bulkhead or hull)
• Suitable for installations where amp draw is up to 15 amps
• Compact design
• Can be used as a high water bilge alarm (when vertically mounted)
Model Specifications
Model Whale Float Switch
Product No. BE9002
Voltage D.C. 12V d.c. or 24V d.c.
Current Suitable for up to 15 Amps
Suitable for Orca and Supersub Standard Submersible ranges see pages 26 and 28
Note: These specifications are retail items only. For details of our bulk pack range for boat builders and wholesalers - contact Whale Support.
48
48 Manual Bilge
Side View
BE9002
Side View Plan View
Schisausrüster
Tel.: +49 (0)40 - 88 9 0 100
www.toplicht.de
Page 2
BE9003(B) / BE9006(B)
Automatic Switch with Electric Field Sensor Technology
Déclencheur automatique avec technologie de capteurs à champs électriques
Model Number Description
BE9003
Automatic Switch with Electric Field Sensor
Technology
BE9006
Automatic Switch with Electric Field Sensor
Technology - 30 second delay
Page 3
Thank you for purchasing this Whale® product.For over 40 years Whale® has led the way in the design and manufacture of freshwater and waste systems including - plumbing, faucets, showers and pumps for low voltage applications. The company and its products have built a reputation for quality, reliability and innovation backed up by excellent customer service. For information on our full product range visit: www.whalepumps.com
1. SPECIFICATION 4. TO THE USER 7. INSTALLATION 10. PATENTS AND TRADEMARKS
2. LIST OF CONTENTS 5. APPLICATION 8. MAINTENANCE 11. WARRANTY
3. TO THE FITTER 6. WARNINGS 9. SERVICE SUPPORT 12. DECLARATION OF CONFORMITY
Check that the product is suitable for the intended application, follow installation instructions and ensure all relevant personnel read the points listed below. Also ensure these instructions are passed on to the end user. WARNING: Please note that incorrect installation may invalidate the warranty.
Read the following instructions carefully.
This Whale® Electric Field Sensor senses water level and automatically controls a 12 or 24 volt bilge pump. The switch turns on when it senses 51mm (2") water level and turns off when water is below 13mm (1/2"). This product is designed for use in pleasure boat applications, and is not intended to be used for commercial boating applications or any other use.
1. Not suitable for use with flammable liquids, diesel, chemicals etc.
2. Suitable for only freshwater or bilge water. If it is intended for any other purpose or with any other liquid, it is the users responsibility to ensure that the switch is suitable for the intended use and, in particular, that the materials are fully compatible with the liquids to be used.
3. Failure to fuse and connect wires according to these instructions will void product warranty and may cause damage or serious injury.
4. Connect in-line fuse (Note: Fit the appropriate amperage specified for your pump model).
5. Correct voltage range is 10.5 V d.c. to 28.8 V d.c. DO NOT use with other voltage, with A.C., or A.C.to D.C. converted power sources.
6. The Electric Field Sensor may draw up to a maximum of 20 amps.
7. NOTE - Maximum operating temperature ~ 60°. Maximum flash temperature ~ 90°
7.1 Location
1. Mount the switch vertically as shown in fig. 1 (wires located uppermost). Locate the switch as close to the pump as possible to ensure the same water level.
2. Prepare a mounting block. Do not fasten switch directly to the hull. Mounting block should be minimum 10mm (3/8") thick marine plywood epoxied to the hull.
3. Switch base may be located up to 6mm (1/4") higher, but NEVER located lower than base of the pump.
7.2 Mounting
1. Use switch base (Fig. 1) or mounting ears (Fig.
2) as a template to mark pilot holes in mounting block.
2. Set drill depth gauge to avoid drilling through hull. Drill two 3mm (1/8") diameter pilot holes.
3. Fasten switch onto mounting block with #8 x 1/2" (3.5mm diameter x 13mm) stainless steel screws (not supplied).
1. SPECIFICATION
Model Number BE9003 - Electric Field Sensor BE9006- Electric Field Sensor with 30 Second Time Delay
Voltage 12 V d.c. or 24 V d.c.
Current Suitable for up to 20 Amps
Residual Current 0.008 Amp
3. TO THE FITTER
4. TO THE USER
5. APPLICATION
6. WARNINGS
2. LIST OF CONTENTS
7. INSTALLATION
Fig 1 Using Switch Base Fig 2 Using Mounting Ears
INSTRUCTION AND INSTALLATION MANUAL
Page 4
7.3 Wiring
1. From positive battery terminal, connect fuse (rated for pump) and 3-way switch for off / manual / automatic switching:
Manual terminal directly to brown (+) pump wire.
Automatic terminal to switch brown/white stripe (+)
Switch brown (-) to pump brown (+).
BLACK (-) pump wire to negative battery terminal
2. Make all wiring connections above highest water level, using permanent waterproof terminals. Coat terminals with liquid electrical tape.
7.4 Testing
1. After installation, hold fingers for 10 seconds on two raised circles on switch face.
If wiring is correct, pump activates.
Remove top finger, pump stays on.
Remove bottom finger, pump should turn off after a short delay.
NOTE: BE9006(B) has a longer override delay of 30 seconds.
2. Test with water in bilge to test that pump turns on and off properly. If not, reposition switch for proper activation.
1. Keep fuse and wiring connections high and dry.
2. Keep floating debris away from Whale switch.
3. Test switch as per section 4 annually
Winterizing - Fully drain system for winterising
.
For installation or service advice please contact Whale customer support:
UK - Tel: +44 (0)28 9127 0531 Fax: +44 (0)28 9146 6421 Email: info@whalepumps.com USA Tel: +1 802 367 1091 USA Fax: +1 802 367 1095 USA Email: usasales@whalepumps.com
Whale® is a registered trademark of Munster Simms Engineering Ltd, Bangor, Northern Ireland.
This product and the technology it uses are protected by US patent numbers - 5594222 / 6310611 / 6320282
The Whale® switches BE9003(B) and BE9006(B) are covered by a 1 year warranty. For warranty details please refer to the enclosed copy of Whale's Statement of Limited Warranty.
Copyright Whale 2013 All rights reserved. WHALE®, is a registered trademark of Munster Simms Engineering Limited, Bangor Northern Ireland (trading as Whale and Whale Seaward Inc.). Whale’s policy is one of continuous improvement and we reserve the right to change specifications without prior notice.
Illustrations are for guidance purposes only.
Fig 3 - Wiring instructions
Brown / white stripes wire
Brown wire
Test Circle
2” (51mm) ON
1/2” (13mm) OFF (Note: BE9006(B) 30 sec override delay)
Mounting Block
3/8” (10mm)
Waterproof Connector Above Water Level
Fuse
Brown Wire
Black Wire
Manual
Automatic
3 Way Switch
Off
12 to 24 V
d.c. Power
3/8” (10mm) min. Mounting Plate
Pump
Switch Wire Colour
Positive
Brown/White
Stripes
Signal Out Brown
Fig 4 - Testing Switch
8. MAINTENANCE
9. SERVICE SUPPORT DETAILS
10. PATENTS AND TRADEMARKS
11. WARRANTY
Page 5
This product complies with all relevant European directives and standards. Please contact Whale® if further details are required.
Manufacturer’s Declaration - We hereby declare, under our sole responsibility, that the enclosed equipment complies with the provisions of the following EC Directives.
94/25/EC amending 2003/44/EC - Recreational Craft Directive 2004/108/EC - EMC Directive
Based on the following harmonized standards EN55022: 2006 + A1:2007 EMC Radiated Emissions EN55014: 2006 + A1:2009 EMC Conducted Disturbance Power EN55014: 1997 + A2:2008 EMC Immunity
CE mark affixed: 28/09/11
Basis on which conformity is declared - The above equipment complies with the protection requirements of the EMC
Directive and the principal elements of the safety objectives of the EC Directives.
Standards applied
EN 28846:1993 Ignition Protected ISO 15083:2003 Bilge Pumping Systems ISO 10133:2000 Extra Low Voltage d.c. Installations
Date: 28th September 2011 Position: Engineering Director
12. DECLARATION OF CONFORMITY AND STANDARDS
Page 6
Merci d’avoir acheté ce produit. Depuis plus de 40 ans, Whale ® a ouvert la voie à la conception et la fabrication de systèmes d'eau douce et de traitement des eaux usées incluant: les pompes, la plomberie, les robinets et les douches pour les applications basse tension. L'entreprise et ses produits se sont construit une réputation grâce à la qualité, la fiabilité, l'innovation, et un excellent service client. Pour plus d'informations sur notre gamme complète de produits, visitez www.whalepumps.com
1. CARACTERISTIQUES 4. A L’UTILISATEUR 7. INSTALLATION 10. BREVETS/MARQUES DEPOSEES
2. CONTENU 5. APPLICATION 8. ENTRETIEN 11. DECLARATION DE GARANTIE
3. POUR L’INSTALLATEUR 6. MISES EN GARDE 9. SUPPORT CLIENT 12. DECLARATION DE CONFORMITE
Vérifiez que le produit est adapté pour l’utilisation voulue et suivez ces instructions d'installation. Assurez-vous que tout le personnel concerné lira les points énumérés ci-dessous. Veillez également à ce que ces instructions soient transmises à l'utilisateur final. ATTENTION : Merci de noter qu’une installation incorrecte peut annuler la garantie
Lisez les instructions suivantes.
Ce déclencheur Whale détecte le niveau de l’eau et contrôle automatiquement une pompe de 12V ou 24V. Le contact du déclencheur se ferme quand il détecte un niveau d’eau de 51 mm et s’ouvre quand le niveau repasse en-dessous de 13mm. Ce produit est destiné à être utilisé pour des applications sur des bateaux de plaisance, et n’est pas destiné à être utilisé sur des bateaux commerciaux ou pour tout autre usage.
1. Ne convient pas pour le pompage de liquides inflammables, de diesel, de produits chimiques, etc.
2. Convient uniquement pour le pompage de l’eau de cale, de l’eau douce ou des eaux grises. Si le déclencheur est destiné à être utilisé à d'autres fins ou avec tout autre liquide, il est de la responsabilité de l'utilisateur de s'assurer que le déclencheur est adapté pour l'utilisation prévue et, en particulier, que les matériaux sont entièrement compatibles avec les liquides qui vont êtres utilisés.
3. Un défaut de connexion des fils selon les instructions annulera la garantie des produits et peut être la cause de dommages ou de blessures graves.
4. Connectez le fusible en ligne (Remarque: montez un fusible avec l’ampérage approprié qui est spécifié pour votre modèle de pompe).
5. La plage de tension correcte va de 10.5 V d.c. à 28.8 V d.c. NE PAS utiliser avec d’autres tensions, avec du courant alternatif ou avec du courant alternatif mal converti en courant continu.
6. La pompe de cale peut consommer jusqu’à un maximum de 20 ampères.
7. REMARQUE - Température maximale de fonctionnement ~ 60°. Température maximale pour une courte période
~ 90°
7.1 Positionnement
1. Montez le déclencheur verticalement comme montré dans la Fig.1 (Fils positionnés le plus haut possible). Positionner le déclencheur aussi proche que possible de la pompe pour garantir le même niveau d’eau.
2. Préparez un panneau de montage. Ne pas fixer le déclencheur directement à la coque. Le panneau de montage doit être d’au minimum 10mm d’épaisseur en contreplaqué époxy marine.
3. Le déclencheur ne doit JAMAIS être positionné plus bas que la base de la pompe
1. CARACTERISTIQUES
Code produit BE9003 - Déclencheur automatique
BE9006- Déclencheur automatique avec un délai de
retardement de 30 secondes
Tension nominale 12 V d.c. ou 24 V
Courant Convient jusqu'à 20A
Courant de veille 0.008 A
3. POUR L’INSTALLATEUR
4. A L’UTILISATEUR
5. APPLICATION
6. MISES EN GARDE
2. CONTENU
7. INSTALLATION
MANUEL D’INSTALLATION ET DE FONCTIONNEMENT
Fig 1 Utilisation de la base du
déclencheur
Page 7
7.2 Montage
1. Utilisez la base ou les pattes de fixation du déclencheur (Fig. 1 et 2) comme modèle pour marquer la position des trous dans le panneau de montage.
2. Réglez la butée de profondeur de la perceuse pour éviter de percer à travers la coque. Percez 2 trous d’un diamètre de 3mm.
3. Fixez le déclencheur sur le panneau de montage avec des vis en acier inoxydable (13mm x 3.5mm de diamètre) (non fournis).
7.3 Câblage
1. De la borne positive de la batterie, connectez le fusible (approprié pour la pompe) et les 3 voies de l’interrupteur pour la marche manuelle/l’arrêt/la marche automatique:
Borne Manuelle directement au fil marron (+) de la pompe
Borne Automatique au fil marron/blanc rayés (+)
Fil marron (-) du déclencheur au fil marron (+) de la pompe.
Le fil Noir (-) de la pompe à la borne négative de la batterie.
2. Faites toutes les connections électriques au-dessus du plus haut niveau d’eau, en utilisant des connecteurs étanches. Recouvrez les connecteurs avec du ruban adhésif étanche ou une gaine thermodurcissable.
7.4 Test
1. Après l’installation, maintenir vos doigts 10 secondes sur les deux cercles en relief de la face du déclencheur
Si le câblage est correct, la pompe s’active.
Retirez votre doigt du cercle du haut, la pompe reste activée.
Retirez votre doigt du cercle du bas, la pompe devrait s’arrêter après un court
délai
REMARQUE: BE9006(B) a un délai de retardement de 30 secondes à l’arrêt
2. Testez avec de l’eau dans la cale pour vérifier que la pompe s’active et s’arrête correctement. Si ce n’est pas le cas, repositionnez le déclencheur pour une activation correcte.
1. Gardez le fusible et les connexions des câbles secs et en hauteur.
2. Gardez les débris flottants à l’écart du déclencheur Whale.
3. Testez le déclencheur annuellement selon l’article 7.4.
Hivernage – Vidanger entièrement le système pour l’hivernage
Pour des conseils d’installation ou d’utilisation merci de contacter le service client Whale: Tel: +44 (0)28 9127 0531 Fax: +44 (0)28 9146 6421 Email: info@whalepumps.com USA Tel: +1 802 367 1091 USA Fax: +1 802 367 1095 USA Email: usasales@whalepumps.com
Whale® est une marque déposée de Munster Simms Engineering Ltd, Bangor, Irlande du Nord.
Ce produit et la technologie utilisée sont protégés par les brevets US- 5594222 6310611 6320282
Fig 3 - Instructions de câblage
Fil marron /blanc rayé
Fil marron
Test de circuit
ON 51mm
OFF 13mm
((Remarque:
BE9006B a une tempo. à l’arrêt de 30 secondes)
Panneau de
montage 10mm
Connecteur étanche au-dessus du niveau de l’eau
Fusible
Fil marron
Fil noir
Manuel
Automatique
Interrupteur 3 voies
Off
Alimentation
de 12 a 24
V.
Panneau de montage de 10mm minimum
Pompe
Fils du
déclencheur
Couleur
Positif
Marron / blanc rayé
Négatif
Marron
Fig 4 - Test du déclencheur
8. ENTRETIEN
9. LE SUPPORT CLIENT
10. BREVETS/MARQUES DEPOSEES
Fig 2 Utilisation des pattes de fixation
Page 8
Les déclencheurs Whale® BE9003(B) et BE9006(B) sons couverts par une garantie de 1 an. Pour les détails sur la garantie merci de vous référez au document de déclaration de garantie limitée Whale.
©Copyright Whale® 2013- All rights reserved.
WHALE® est une marque déposée de Munster Simms Engineering Limited, Bangor Northern Ireland commercialisant sous le nom de Whale® et Whale Seaward Inc.
La politique de Whale® est une politique d’amélioration continue et nous nous réservons le droit de changer les spécifi­cations sans avertissement préalable.
Les illustrations sont présentes à titre d’information seulement.
Ce produit est conforme à toutes les directives et normes européennes. Merci de contacter Whale ® si des précisions sont nécessaires.
Déclaration du fabricant - Nous déclarons, sous notre seule responsabilité, que le matériel ci-joint est conforme aux dispositions des directives de la CE.
94/25/EC amandant 2003/44/EC - Directive Véhicules de Loisirs 2004/108/EC - Directive CEM
Basé sur les standards harmonisés suivants
EN55022: 2006 + A1:2007 CEM Emissions EN55014: 2006 + A1:2009 CEM Bruits de puissance conduits EN55014: 1997 + A2:2008 CEM Immunité
Marque déposé CE: 28/09/11
Fondement sur lequel la conformité est déclarée
Le matériel ci-dessus est conforme aux exigences de sécurité de la directive CEM et les principaux éléments des objectifs de sécurité de la Directive CE.
Normes appliquées
EN 28846:1993 Protection à l'étincelle ISO 15083:2003 Systèmes de pompage de cale ISO 10133:2000 Installations très basse tensions d.c.
Date: 28 Septembre 2011 Poste: Le responsable de l’ingénierie
12. DECLARATION DE CONFORMITE, STANDARDS, CERTIFICATIONS
11. DECLARATION DE GARANTIE
Page 9
Whale - Munster Simms Engineering Ltd. Old Belfast Road, Bangor, N. Ireland BT19 1LT
Tel: +44 (0)28 9127 0531 Fax: +44 (0)28 9146 6421 Email: info@whalepumps.com
Whale Seaward Inc. 91 Manchester Valley Road, Manchester, Vermont, 05255
Tel: +1 802 367 1091 Fax: +1 802 367 1095 Email: usasales@whalepumps.com
www.whalepumps.com
Copyright Whale 2013- All rights reserved.
WHALE®, is a registered trademark of Munster Simms Engineering Limited, Bangor Northern Ireland (trading as Whale and Whale Seaward Inc.).
Whale’s policy is one of continuous improvement and we reserve the right to change specifications without prior notice.
Illustrations are for guidance purposes only.