Detailed Specification & Technical Data
WP9B240T
Interlocked Armor Distribution Cable - 6 Fiber OM1 OFCP
Audio, Video and Data
Construction & Dimenstions
CONSTRUCTION & DIMENSIONS
CONDUCTOR PARAMETER
• Number Of Fibers 6
• Fiber Optic Size 62.5/125
• OM Fiber Optic Rating OM1
INSULATION PARAMETER
• Insulation Type ermoplastic
• Buer Size 900 m
• Insulation Color Code 1.Blue,2.Orange,3.Green,4.Brown,5.Slate,6.White
SHIELDING PARAMETER
• Fiber Optic Design Indoor/Outdoor Plenum Direct Burial
• Armor Type Interlocked Aluminum
• Flooding Compound Ye s
ELECTRICAL CHARACTERISTICS
-
-
-
-
-
Overall Construction
OVERALL CONSTRUCTION PARAMETERS
Jacket Type UV Resistant Polyolein
Nominal Cable O.D. .506
Plenum Ye s
NEC UL Rating OFCP
RoHS Compliant Ye s
TIA Test TIA455-82 Water Penetration Test, MEETS ICEA S-104-696 TEST CRITERI (CORE CABLE
Pull Tension 270 lbs
Bend Radius 7.6 in
Cable Weight 102 lbs
-
ON LY)
Overall Electrical & Optical Characteristics
OVERALL ELECTRICAL/OPTICAL CHARACTERISTICS
UL Flammability NFPA 262
CSA Flammability FT6
Operating Range -40°C To +70°C
Operating Wavelength 850/1300 nm
Min. OFL Bandwidth 200/500 MHz.km
Max. Attenuation 3.50/1.25 dB/km
-
2833 West Chestnut Street | Washington, PA 15301 | Toll Free: 800-245-4964 | www.westpenn-wpw.com