2833 West Chestnut Street
This document is the property of West Penn Wire.
Standard Lengths a re 1000ft.
Technical Data Sheet
Communication Cables
PART NUMBER:
DESCRIPTION: 10/2 Stranded bare copper conductors, unshielded & Jacketed- Cluster Speaker Cable
NEC RATING: CL2, NEC Article 725
APPROVALS: (UL) or (ETL)us Listed
APPLICATION: Indoor for: Cluster Speaker.
Construct ion Parameters:
Conductor 10 AWG Bare Copper
Stranding 65x28
Insulation Material Polyolefin
Insulation Thickness 0.012” Nom.
Number of Conductors 2
Shield None
Drain None
Jacket Material PVC
Jacket Thickness 0.025” Nom.
Overall Cable Diameter 0.275'' Nom.
Approximate Cable Weigh t 105 Lbs/1M' Nom.
Flame Rating UL1685
Electrical & Environm e n tal Properties:
Temperature Rating -20deg C to 60deg C
Operating Voltage 300 V RMS
Max.Capacitance Between C onductors @ 1 KHz 32 pf/ft Nom.
DC Resistance per Conductor @ 20deg C 1.10 Ohms/1M' No m.
Insulation Colors Black ,White
Jacket Color Gray
RoHS Compliant Yes
Mechanical Properties:
Max. Recommended Pu ll Tension 220 Lbs.
Min. Bend Radius (Install) 2.7”
Specification Issu e Date: 7/12
.
The inform at i o n contained herein is consider ed
Proprietary and not to be reproduced by any means
Without written consent of West Penn Wire
HA210
Washington, PA 15301
Toll Free: (800) 245-4964
Fax: (724) 222-6420
www.westpenn-wpw.com
The Jacket is sequentially footmarked.
The information presented here is, to the best of our
knowledge, is true and accurate. However , since
conditions of use are beyond our control, all
recommendations or sugg estions are presented
without guarantee or resp onsibility on our pa r t. We
disclaim all liabilit y in connection with the use of
information contained herein or otherwise.