West Penn D441GY0500 Specsheet

Detailed Specification & Technical Data
D 4 41
3Pr. 18AWG Ind. Shielded CM
Audio and Control
Construction & Dimensions
CONSTRUCTION & DIMENSIONS CONDUCTOR PARAMETER
• Number of Pairs 3
• AWG Size 18
• Conductor Stranding 7x26
• Conductor Type Tinned Copper
• Nominal DCR 10.5 Ohm/1000
• Insulation Type Polypropylene - PP
• Insulation ickness 0.008 in
• Insulation Color Code 1. Black-Rd, Red, 2.Black-Wh, White 3.Black-Gn, Green
SHIELDING PARAMETER
• Shield Type Individually Shielded
• Drain Wire Type Tinned Copper
• Drain Wire AWG 24 AWG
ELECTRICAL CHARACTERISTICS
• Nom. Cap. Between Conductors 40 pF/
• Nom. Cap. Conductor to Shield 73 pF/
-
-
-
-
-
Overall Construction
OVERALL CONSTRUCTION PARAMETERS
Total Number of Conductors 6
Jacket Type PVC
Jacket ickness 0.017 in
Nominal Cable O.D. 0.285 in
Plenum No
NEC UL Rating CM
RoHS Compliant Yes
Pull Tension 67 lbs
Bend Radius 2.565 in
Cable Weight 55 lbs
-
Overall Electrical & Optical Characteristics
OVERALL ELECTRICAL/OPTICAL CHARACTERISTICS
UL Flammability UL1685
Operating Range -20 to 60 Deg C
UL Voltage Rating 300
-