West Penn D254852GY1000 Specsheet

Technical Data Sheet Plenum Data Grade RS-485 Cables
PART NUMBER:
DESCRIPTION: 24/4 (2 Pair) Stranded tinned copper conductors, shielded with an overall jacket.
NEC RATING: CMP, NEC Article 800
APPLICATION: Indoor Plenum data cable for: Computer Application, Low-Capacitance Data.
D254852
2833 West Chestnut Street
Washington, PA 15301
Toll Free: (800) 245-4964
Fax: (724) 222-6420
www.westpenn-wpw.com
Construction Parameters:
Conductor 24 AWG Tinned Copper Stranding 7x32 Insulation Material Foamed Teflon Number of Conductors 4 (2 Pair) Shield 100% Aluminum Polyester Foil Drain Stranded Tinned Copper Jacket Material Plenum PVC Overall Cable Diameter 0.305'' Nom. Approximate Cable Weight 38 Lbs/1M' Nom. Flame Rating NFPA-262
Electrical & Environmental Properties:
Temperature Rating -20deg C to 60deg C Operating Voltage 300 V RMS Max.Capacitance Between Conductors @ 1 KHz 12.8 pf/ft Nom. Capacitance Between Conductors to Shield @ 1 KHz 23 pf/ft Nom. DC Resistance per Conductor @ 20deg C 24 Ohms/1M' Nom. Velocity of Propagation 72% Nom. Impedance 120 Nom Insulation Colors 1. Blue- White/Blue, 2 Orange-White/Orange Jacket Color Gray RoHS Compliant
Mechanical Properties:
Max. Recommended Pull Tension 56 lbs. Min. Bend Radius (Install) 3.”
Specification Issue Date: 3/08
This document is the property of West Penn Wire.
.
The information contained herein is considered Proprietary and not to be reproduced by any means Without written consent of West Penn Wire
Standard Lengths are 1000ft. The Jacket is sequentially footmarked. The information presented here is, to the best of our knowledge, is true and accurate. However, since conditions of use are beyond our control, all recommendations or suggestions are presented without guarantee or responsibility on our part. We disclaim all liability in connection with the use of information contained herein or otherwise.