Technical Data Sheet
CN-111S90H34
Cat 6 Shielded – F/UTP
Modular Plug with Loading Bar
.
2833 West Chestnut Street
Washington, PA 15301
Toll Free: (800) 245-4964
Fax: (724) 222-6420
www.westpenn-wpw.com
Description
- Eight conductor modular Plug
- High speed data applications
Conductors – with an OD range of .044-.048”
-
Solid or Stranded Conductors
-
Shielded Category 6
-
Cable OD up to .310
-
Application
• Hospitals < EMI / RFI >
• Manufacturing plants
• Casinos
• Broadcast studios
• Buildings in proximity to microwave towers,
electrical power stations or towers
Technical Data
- Meets or exceeds Cat6 ANSI/EIA 568-C.2
Cables
- M58163 (4246F) – Cat6 F/UTP – CMR
- M58183 (254246F) – Cat6 F/UTP - CMP
Boot
- CN-B0051 – Black 8mm Boot
PREPARE THE CABLE
STRIP 1-1.25 INCH.
CUT FOIL AND CLEAR MYLAR TAPE
CUT AWAY CENTER ELEMENT.
FOLD DRAIN WIRE BACK OVER
THE JACKET
FLATTEN THE WIRES
AND ASSEMBLE IN THE APPROPRIATE
PAIR 3
PAIR 1
WIRING CONFIGURATION
568A OR 568B
W-G G W-O BL W-BL O W-BR BR
CONFIGURATION - 568A
568B
FEED THE CONDUCTORS INTO THE LOADING BAR.
VISUALLY CHECK TO MAKE SURE CONDUCTORS ARE
SEPARATED. THIS ENSURES PROPER SEATING INTO CONNECTOR BODY
CUT IN A SLIGHT ANGLE
DO NOT CUT ANGLE TOO SHARP
FOLD THE DRAIN RELIEF HOOD BACK
INSERT THE WIRES INTO THE CONNECTOR BODY
CHECK TO SEE IF THE WIRES ARE INSERTED CORRECTLY.
PAIR 4
PAIR 3
W-O O W-G BL W-BL G W-BR BR
CONFIGURATION - 568B
1/16 “
PAIR 2
PAIR 1
1/2 “
PAIR 4
USING CRIMP - TL-EZRJ45 OR TL-114 CRIMP THE CONNECTOR
or 900020
PUSH THE DRAIN RELIEF
DOWN OVER THE JACKET WRAP DRAIN WIRE AROUND THE DRAIN RELIEF OR CABLE
CUT EXCESS DRAIN WIRE - IF NEEDED
FOLD THE DRAIN POSTS AROUND THE CABLE - USING TL-KLIEN TOOL
Or Pliers - or USE 900020 Crimp Tool
Slide - CN-B0051 Boot onto connector Body