Technical Data Sheet
Video over UTP Cable- Plenum
PART NUMBER:
DESCRIPTION: 2 Pair Cat5E Type + 2 Cond. 16AWG. Siamese Construction. Plenum Jacket
NEC RATING: CMP
APPROVALS: (UL) Listed
APPLICATION: Indoor Plenum area for: CCTV over UTP
CC252416
2833 West Chestnut Street
Washington, PA 15301
Toll Free: (800) 245-4964
Fax: (724) 222-6420
www.westpenn-wpw.com
Construction Parameters: Video and Control Pairs
Conductor 24 AWG Bare Copper
Stranding Solid
Insulation Material Plenum Thermoplastic .008”
Number of Conductors 4 (2 Pair)
Shield None
Construction Parameters: Power Conductors
Conductor 16 AWG Bare Copper
Stranding Stranded
Insulation Material Plenum PVC- .008”
Number of Conductors 2
Shield None
Electrical & Environmental Properties: Video and Control Pairs
Temperature Rating -20deg C to 60deg C
Operating Voltage 300 V RMS
Max.Capacitance Between Conductors @ 1 KHz 14pf/ft.
Nom. Impedance 100 Ohms
Nom. Velocity of Propagation 66%
DC Resistance per Conductor @ 20deg C 26 Ohms/1M' Nom.
Insulation Colors Blue/White-Blue, Orange/White-Orange
Electrical & Environmental Properties: Power Conductors
Temperature Rating -20deg C to 60deg C
Operating Voltage 300 V RMS
Max.Capacitance Between Conductors @ 1 KHz NA
DC Resistance per Conductor @ 20deg C 4.2 Ohms/1M' Nom.
Insulation Colors Black, Red
Overall Construction:
Jacket Type ` Plenum PVC
Jacket Color Siamese - Gray
Nom. O.D. .190” x.350”
Mechanical Properties:
Max. Recommended Pull Tension 50 lbs.
Min. Bend Radius (Install) 3.50”
Put ups:
1000ft
Specification Issue Date: 10/10
This document is the property of West Penn Wire.
.
The information contained herein is considered
Proprietary and not to be reproduced by any means
Without written consent of West Penn Wire
Standard Lengths are 1000ft.
The Jacket is sequentially footmarked.
The information presented here is, to the best of our
knowledge, is true and accurate. However, since
conditions of use are beyond our control, all
recommendations or suggestions are presented
without guarantee or responsibility on our part. We
disclaim all liability in connection with the use of
information contained herein or otherwise.