West Penn C2051000 Specsheet

Technical Data Sheet Communication Cables
PART NUMBER:
DESCRIPTION: 16/2 Stranded bare copper conductors, unshielded & unjacketed- Cluster Speaker Cable
NEC RATING: CL2, NEC Article 725
APPLICATION: Indoor for: Cluster Speaker.
2833 West Chestnut Street
Washington, PA 15301
Toll Free: (800) 245-4964
Fax: (724) 222-6420
www.westpenn-cdt.com
C205
Construction Parameters:
Conductor 16 AWG Bare Copper Stranding 19/29 Insulation Material PVC/ Nylon Insulation Thickness 0.015'' PVC Nom.
0.005” Nylon Nom. Number of Conductors 2 Shield None Drain None Jacket Material None Jacket Thickness None Overall Cable Diameter 0.194'' Nom. Approximate Cable Weight 24Lbs/1M' Nom. Flame Rating UL1685
Electrical & Environmental Properties:
Temperature Rating -20deg C to 60deg C Operating Voltage 300 V RMS Max.Capacitance Between Conductors @ 1 KHz 33 pf/ft Nom. DC Resistance per Conductor @ 20deg C 4.2 Ohms/1M' Nom. Insulation Colors Black White Jacket Color None RoHS Compliant --
Mechanical Properties:
Max. Recommended Pull Tension 56 Lbs. Min. Bend Radius (Install) 1.9”
Specification Issue Date: 7/06
This document is the property of West Penn Wire.
.
The information contained herein is considered Proprietary and not to be reproduced by any means Without written consent of West Penn Wire
Standard Lengths are 1000ft. The Jacket is sequentially footmarked. The information presented here is, to the best of our knowledge, is true and accurate. However, since conditions of use are beyond our control, all recommendations or suggestions are presented without guarantee or responsibility on our part. We disclaim all liability in connection with the use of information contained herein or otherwise.
Loading...