West Penn AV-IP-C8-WH, AV-IP-C8PG-WH User Manual

8 Button IP Controller Installation & Operation Manual
8 Button IP Controller
Installation and Operation Manual
© West Penn Wire 2018 94-000880-A / SE-000880-A Page 1 / 20
8 Button IP Controller Installation & Operation Manual
Introduction
The 8 Button IP Controller (Model: AV-IP-C8-WH) is a versatile wall or table-top mounted control panel for West Penn Wire AV over IP devices, select Matrix Switches, and third party products. Each button is programmable. The unit supports one (1) Ethernet port (for TCP/IP and Telnet), two (2) RS-232 ports, one (1) Infrared port, and two (2) Relay ports, for control of end devices. The 8 Button IP Controller can control West Penn Wire products including West Penn Wire’s AV over IP system via the AV-IP-NC811 IP Device Controller, plus TCP/IP, Telnet and RS-232 managed Matrix Switches, as well as third party devices such as projectors and projector screens, displays, AV sources and other similar devices.
The AV-IP-C8-WH supports a web interface, allowing it to be configured and managed via a browser. The web interface allows the unit keys to be programmed individually, supports IR learning and unit configuration.
Panel Description
Front panel view:
All buttons can be programed to control each TCP/IP, Telnet, RS-232, IR, and Relay controllable end device. Each key supports a removable clear plastic cover, allowing a label to be inserted to reflect the programming of each button.
© West Penn Wire 2018 94-000880-A / SE-000880-A Page 2 / 20
8 Button IP Controller Installation & Operation Manual
Rear panel view:
1. Power: DC Power Input supporting 12-24VDC (12VDC@1A is recommended)
2. Relay #1: An electrically operated switch
3. IR output power jumper: jumper left 2 pins for 5V, or right 2 pins for 10V.
4. Relay #2: An electrically operated switch
5. IR: Infrared radiation digital data output
6. Rs232 #2: RS-232 data output
7. Rs232 #1: RS-232 data output
8. LAN (PoE): LAN port with PoE (PD) power for web interface control
Top panel view:
1. IR reader: Learning IR sensor, supporting a frequency of 38KHz
© West Penn Wire 2018 94-000880-A / SE-000880-A Page 3 / 20
8 Button IP Controller Installation & Operation Manual
Configuation: Unit Initialization
Before initial use, the user must initialize (factory reset) the AV-IP-C8-WH configuration. To initialize the unit, press and hold the first, third and fifth key as indicated below. Continue to hold these keys while the unit goes through the following illuminated key color sequence, including the lights of these three buttons will turn off, then each of the eight buttons will illuminate (turn on) in red one by one until all are lit, and then they will all flash in green to end the sequence. This sequence is shown below. Note that this restores the factory default settings.
Web Server
The units comes with a factory default IP Address of: 192.168.168.54
To access the unit web server, the user can directly connect a PC LAN port to the AV-IP-C8-WH LAN port with a straight polarity Ethernet cable. After connecting the PC and 8 Button IP Controller, go to the PC network connection section to change the PC’s IP property status to “Static IP and set the PC IP address to say 192.168.168.178, Subnet Mask to 255.255.255.0 and Default Gateway to 192.168.168.1, as shown below. Once done, open a web browser and enter the IP Address 192.168.168.54 to access to the AV-IP-C8-WH web server.
© West Penn Wire 2018 94-000880-A / SE-000880-A Page 4 / 20
8 Button IP Controller Installation & Operation Manual
The user must now set the 8 Button IP Controller to the same IP segment as the local area network where the device will be used. To accomplish this go to the Network section via the AV-IP-C8-WH web interface, see below, and set the 8 Button IP Controller IP address accordingly to match the local area network IP Address setting.
For example if the LAN IP segment is set as 192.168.88.xxx, then set the product IP Address to 192.168.88.1xx. Once the IP Address is set, then the user can access this device in the intended local area network via the AV-IP-C8-WH web interface using the IP Address 192.168.88.1xx (where xx represents the settings selected above).
© West Penn Wire 2018 94-000880-A / SE-000880-A Page 5 / 20
8 Button IP Controller Installation & Operation Manual
The factory default:
IP: 192.168.168.54
User ID: admin
Password: admin
After accessing the 8 Button IP Controller web server, the default user ID is admin, and the password is admin. Login to configure and manage the unit.
Setting Menu
After login, go to the Setting Menu to manage LAN, RS-232, IR parameters, User ID and Password, and Button rename.
IR Learning: Please go to the IR Event chapters for further details.
Lan Control / Net Control: Users can set DHCP, IP Address, Subnet Mask, Default Gateway, TCP/IP Server, plus Client and Host IP TCP Port info in the Net Control sub-section, see below.
Lan Control / Version Information: Note that System hardware, boot loader and software version information is listed in the Version information sub-section, see below.
© West Penn Wire 2018 94-000880-A / SE-000880-A Page 6 / 20