West Penn 4245162GY1000 Specsheet

Technical Data Sheet­Category 5E Netw
ork+ Power Pair
Washington, PA 15301
Toll Free: (800) 245-4964
Fax: (724) 222-6420
www.westpenn-wpw.com
PART NUMBER:
DESCR
NEC RATING: CMR
APPROVALS: (UL) C(UL) Listed or c(ETL)us Listed
APPLICATION: Indoor - Category 5E Applications- Ethernet, IP Cameras, Digital Integration
Meets TIA/EIA 568B.2 Category 5e Specifications with Power – Nurse Call – Dukane- GE
IPTION: Zip- Siamese Construction: 4 Pair Cat5E + 16/2 Unshielded – Overall Zip Jacket
4245162
Construction Parameters: Data Cable
Conductor 24 AWG Bare Copper Stranding Solid Number of Conductors 8 (4 Pair) Insulation Thermoplastic - Shield None Drain None
Construction Parameters: Power Cable
Conductor 16AWG Bare Copper Stranding Stranded19x19 Number of Conductors 2 Insulation PVC - .008” Shield None Drain None
Overall Construction: Zip (Siamese)
Jacket Material PVC Overall Cable Diameter 0.390x.190” Nom. Approx. Approximate Cable Weight 42 Lbs/1M' Nom. Jacket Color Security Green Flame Rating UL 1666
Electrical & Environmental Properties: Data Cable
Operating Temperature Rating -20°C To +60°C Operating Voltage Rating 300 V RMS DC Resistance per Conductor @ 20deg C 9.38 Ohms/100m Nom. Mutual Capacitance 14pf/ft Nominal Nominal Impedance 100 Ohms+/-15% (1-100Mhz) Velocity of Propogation 66% Nominal Delay Skew 45ns/100m MAX Standards TIA/EIA568-B.2 Insulation Colors 1.Blue/White-Blue, 2. Orange/White-Orange
3. Green/White-Green, 4. Brown/White-Brown
PART NUMBER: 4245162
Electrical & Environmental Properties: Power Cable
Operating Temperature Rating -20°C To +60°C Operating Voltage Rating 300 V RMS DC Resistance per Conductor @ 20deg C 4.2 Ohms/100m Nom. Insulation Colors 1.Black 2. Red
Electrical Specifications: Data Cable
Frequency: MHz 1 10 25 100 200 Insertion NEXT: dB/100m 80 64 59 50 46 ACR: PS-NEXT: PS-ACR: ELFEXT: dB/100m 67.8 47.8 39.8 27.8 21.8 PS-ELFEXT: RL:
Specification Issue Date: 10-201
.
Loss: dB/100m 1.8 5.8 9.3 19.6 28.8
dB/100m 70.3 50.9 41.1 40.3 35.8
dB/100m 73 58 52 43 40
dB/100m 66.3 46.9 37.1 17.3 3.3
dB/100m 64.8 25 36.8 24.8 18.8
dB 20 25 24.3 20.1 18
2
This document is the property of West Penn Wire. The information contained herein is considered Proprietary and not to be reproduced by any means Without written consent of West Penn Wire
Standard Lengths are 1000ft. The Jacket is sequentially footmarked. The information presented here is, to the best of our knowledge, is true and accurate. However, since conditions of use are beyond our control, all recommendations or suggestions are presented without guarantee or responsibility on our part. We disclaim all liability in connection with the use of information contained herein or otherwise.