West Penn 420GY0500 Specsheet

Detailed Specification & Technical Data
420
2 PR 22AWG Solid Ind Shielded CMR
Audio and Control
Construction & Dimensions
CONSTRUCTION & DIMENSIONS CONDUCTOR PARAMETER
• Number of Pairs 2
• AWG Size 22
• Conductor Stranding Solid
• Conductor Type Tinned Copper
• Nominal DCR 17.5 Ohm/1000
• Insulation Type Polypropylene - PP
• Insulation ickness 0.008 in
• Insulation Color Code 1. Black-Rd, Red, 2.Black-Wh, White
SHIELDING PARAMETER
• Shield Type Individually Shielded
• Drain Wire Type Tinned Copper
• Drain Wire AWG 24 AWG
ELECTRICAL CHARACTERISTICS
• Nom. Cap. Between Conductors 34 pF/
• Nom. Cap. Conductor to Shield 67 pF/
-
-
-
-
-
Overall Construction
OVERALL CONSTRUCTION PARAMETERS
Total Number of Conductors 4
Jacket Type PVC
Jacket ickness 0.017 in
Nominal Cable O.D. 0.195 in
Plenum No
NEC UL Rating CMR, CMG
RoHS Compliant Yes
Pull Tension 39 lbs
Bend Radius 1.75 in
Cable Weight 25 lbs
-
Overall Electrical & Optical Characteristics
OVERALL ELECTRICAL/OPTICAL CHARACTERISTICS
UL Flammability UL1666 Vertical Sha
CSA Flammability FT4
Operating Range -20 to 60 Deg C
UL Voltage Rating 300
-