P. O. Box 762, 2833 West Chestnut St.
Washington, PA 15301
724-222-7060
FAX: 724-222-6420
TOLL FREE: 800-245-4964
PA CALL: 800-222-8883
Sound and Audio Combination Shielded and Unshielded
55 pf/ft*
180 pf/M*
99 pf/ft**
Capacitance
@ 1 KHZ
325 pf/M**
Conductor
DCR (Resistance)
@ 20° C
17 Ω per 1000 ft.
Electrical Characteristics
Nominal
*Nominal Capacitance between conductors.
**Nominal Capacitance between one conductor and
the other connected to the shield.
This document is the property of WEST PENN WIRE.The
information contained herein is considered proprietary and
not to be reproduced by any means without written
consent of WEST PENN WIRE.
Mechanical Characteristics
Number of Pairs
2 ( 1 shld, 1 unshld)
AWG Size
22
Stranding
(7 x 30)
Nom. Insulation
Thickness
.010
(.25 mm)
Shield Type
% Coverage
100% Aluminum
Polyester Tape
Nom. Jacket
Thickness
.015
(.38 mm)
Nom. O.D.
.168
(4.27 mm)
Drain Wire Size
24 (7 x 32)
357
Rev. 4-10-01
Description:
• Sound and audio special cable
• ASTM tinned copper
• PVC insulation
• Short overall twist lengths
• One pair shielded 100% coverage of aluminum
polyester foil with 24 AWG strd. TC drain wire
• One unshielded Pair
• Overall PVC jacket
• Standard spool size 1000 feet
Rating as per NEC:
• NEC Type CMR
• (UL) - C(UL) or c(ETL)us Listed
• Constructed in accordance with UL Standard 444
• Listed as being resistant to the spread of fire as defined
in section 800
–51 (c) of the National Electric Code; UL
1666 Vertical Tray Flame Test.
• Meets 300 volt requirement as specified in section
800
–51 of the NEC
Applications:
Indoor for:
• Intercom Systems
• Security Systems
• Sound and Audio
• Background Music
• Power–Limited Control Circuits
Color Code:
Shielded Pair:
1. Black, 2. Red
Unshielded Pair:
1. White, 2. Green
Jacket: Gray
Special Notes:
+
C(UL) CMR Canadian UL accepted mark
replaces PCC–FT4