![](/html/cc/cc0c/cc0c34a204949015ea34f7d52961b0a73c955c580a8096840fc5ae8e5a09f835/bg1.png)
2833 West Chestnut Street
This document is the property of West Penn Wire.
Standard Lengths a re 1000ft.
Technical Data Sheet
Communication Cables
PART NUMBER:
DESCRIPTION: 16/2 Stranded bare copper conductors, shielded with an overall jacket
NEC RATING: CMR, NEC Article 800
APPROVALS: (UL) C(UL) Listed or c(ETL)us Listed
APPLICATION: Indoor for: Intercom, Security, Sound, Audio, Background Music, and Power Limited Control
Construct ion Parameters:
Conductor 16 AWG Bare Copper
Stranding 19x29
Insulation Material Polypropylene
Insulation Thickness 0.009'' Nom.
Number of Conductors 2 (1 Pair)
Shield 100% Aluminum Polyester Foil
Drain Stranded Tinned Copper
Jacket Material PVC
Jacket Thickness 0.017'' Nom.
Overall Cable Diameter 0.186'' Nom.
Approximate Cable Weigh t 30.1 Lbs/1M' Nom.
Flame Rating UL 1666 Ri ser Flame Test
Electrical & Environm e n tal Properties:
Temperature Rating -20°C To +60°C
Operating Voltage 300 V RMS
Max.Capacitance Between Conductors @ 1 KHz 45 pf/ft Nom.
Capacitance Between Co nductors to Shield @ 1 KHz 89 pf/ft Nom.
DC Resistance per Conductor @ 20deg C 4.2 Ohms/1M' Nom.
Insulation Colors Black, Red
Jacket Color Gray
RoHS Compliant Yes
Mechanical Properties:
Max. Recommended Pu ll Tension 85.5 lbs.
Min. Bend Radius (Install) 1.9”
Specification Issu e Date: 7/14
.
The inform at i o n contained herein is consider ed
Proprietary and not to be reproduced by any means
Without written consent of West Penn Wire
294
Circuits.
Washington, PA 15301
Toll Free: (800) 245-4964
Fax: (724) 222-6420
www.westpenn-wpw.com
The Jacket is sequentially footmarked.
The information presented here is, to the best of our
knowledge, is true and accurate. However , since
conditions of use are beyond our control, all
recommendations or sugg estions are presented
without guarantee or responsibility on our part. We
disclaim all liability in connection with the use of
information contained herein or otherwise.