![](/html/28/28ce/28ceb9060e822b8b235321be69b845a1b5d31de79648f89a81acb94bdc4b7445/bg1.png)
2833 West Chestnut Street
This document is the property of West Penn Wire.
Standard Lengths a re 1000ft.
Technical Data Sheet
Communication Cables
PART NUMBER:
DESCRIPTION: 18/2 Stranded bare copper conductors, shielded with an overall jacket.
NEC RATING: CMR, NEC Article 800
APPROVALS: (UL) C(UL) Listed or c(ETL)us Listed
APPLICATION: Communications Cable for Riser
Construct ion Parameters:
Conductor 18 AWG Bare Copper
Stranding 7x26
Insulation Material Polypropylene
Insulation Thickness 0.008'' Nom.
Number of Conductors 2
Shield 100% Aluminum Polyester Foil
Drain Stranded Tinned Copper
Jacket Material PVC
Jacket Thickness 0.017'' Nom.
Overall Cable Diameter 0.160'' Nom.
Approximate Cable Weigh t 20.9 Lbs/1M' Nom.
Flame Rating UL 1666 Ri ser Flame Test
Electrical & Environmental Properties:
Temperature Rating -20°C To +60°C
Operating Voltage 300 V RMS
Max.Capacitance Between Conductors @ 1 KHz 40 pf/ft Nom.
Capacitance Between Conductors to Shield @ 1 KHz 79 pf/ft Nom.
DC Resistance per Conductor @ 20deg C 6.6 Ohms/1M' Nom.
Insulation Colors Black, Red
Jacket Color Gray
RoHS Compliant Yes
Mechanical Properties:
Max. Recommended Pu ll Tension 57.5 lbs.
Min. Bend Radius (Install) 1.6”
Specification Issu e Date: 7/14
.
The inform at i o n contained herein is consider ed
Proprietary and not to be reproduced by any means
Without written consent of West Penn Wire
293
Washington, PA 15301
Toll Free: (800) 245-4964
Fax: (724) 222-6420
www.westpenn-wpw.com
The Jacket is sequential ly footmarked.
The information presented here is, to the best of our
knowledge, is true and accurate. However , since
conditions of use are beyond our control, all
recommendations or sugg estions are presented
without guarantee or resp onsibility on our pa r t. We
disclaim all liability in connection with the use of
information contain ed herein or otherwise.