West Penn 25Q841 Data Sheet

Plenecon®RG-6/U Type CATV Plenum Coaxial Cable
Description:
• ASTM bare copper conductor
• Foam Teflon
®
insulation
• Flexible plenum jacket
• Standard spool size 1000 feet
Rating as per NEC:
• UL listed NEC type CL2P as defined in Article 725
• UL listed NEC type CATVP as defined in Article 820
• Constructed in accordance with UL Standard 13
• Complies with UL 910 modified ASTM Steiner Tunnel Test
Applications
Indoor within ducts. plenums and other spaces used for environmental air for:
• CATV
• MATV
Jacket Color: Ivory
16.2 pf per foot
82%
Nominal Capacitance
Conductor to Shield
Nom. Imp. 75
Electrical Characteristics
(Calculated Quantities)
This document is the property of WEST PENN WIRE.The information contained herein is considered proprietary and not to be reproduced by any means without written consent of WEST PENN WIRE.
Construction
Coax Insulation
Nom. O.D.
.170 Foam FEP
(4.32 mm)
First Shield Type
& % Coverage
BiFoil‡100%
25Q841
Rev. 3-10-01
Vel. of Prop.
Nom. D.C.R.
(Resistance) @ 20° C
6.5
per 1000 feet
Jacket Type Flexible Plenum
Mhz db/100 ft db/100 m
5 .45 1.5
55
100 2.0 6.6
1000
Nom. O.D.
.273 inch
(6.93 mm)
54 pf per meter
Coaxial Cable Loss Factors
Nominal Attenuation
400 700
2000 3000
3 Piece
(BNC)
2 Piece
(BNC)
F type
Compression
--- CN-FSNS-6
Suggested Cambridge Connectors
"F Type" (1 Piece)
CN-F56ALM
P. O. Box 762, 2833 West Chestnut St. Washington, PA 15301
724-222-7060
FAX: 724-222-6420
TOLL FREE: 800-245-4964
PA CALL: 800-222-8883
Conductors 1
AWG Size 18 Stranding Solid Bare Copper
BiFoil is an aluminum polyester aluminum tape with 100% coverage
Second Shield Aluminum Braid 65%
Third Shield
BiFoil‡100%
Fourth Shield Aluminum Braid 55%
1.5 4.9
4.2 13.7
5.9 19.3
7.4 24.3
11.9 39
14.8 48.5
Loading...