West Penn 25810NT1000 Specsheet

Technical Data Sheet RG8/U Coaxi
PART NUMBER:
DESCRIPTION: RG8/U – 1 Conductor 12 AWG 7x20, 95% Bare copper braid and an overall Copolymer Jacket.
APPROVALS: (UL) C(UL) Listed
APPLICATION: Indoor Plenum for: 50 Systems
al 50 Ohm - Plenum
25810
2833 West Chestnut Street
Washington, PA 15301
Toll Free: (800) 245-4964
Fax: (724) 222-6420
www.westpenn-wpw.com
Construction Parameters:
Conductor 12 AWG Bare Copper Stranding 7x20 Insulation Material Foam FEP Insulation Thickness .280” Nom. Number of Conductors 1 Center Conductor Shield 95% Bare Copper Braid Jacket Material Copolymer- Solef Overall Cable Diameter 0.352'' Nom. Approximate Cable Weight 98 Lbs/1M' Nom. Flame Rating NFPA 262 Plenum
Electrical & Environmental Properties:
Temperature Rating -40deg C to 75deg C Max.Capacitance Between Conductors @ 1 KHz 28.5 pf/ft Nom. Velocity of Propagation 66% Nom. Impedance 52 ohms Nom. DC Resistance per Conductor @ 20deg C 1.6 Ohms/1M' Nom. Jacket Color Natural RoHS Compliant --
Mhz db/100ft
1 .2 10 .6 50 1.3 100 1.9 400 4.1 700 5.9 900 6.9
Mechanical Properties:
Max. Recommended Pull Tension 183 lbs. Min. Bend Radius (Install) 3.5”
Connectors and Accessories
50 Ohm 3 pc. BNC CN-25810KBNC
Specification Issue Date: 10/11
This document is the property of West Penn Wire.
.
The information contained herein is considered Proprietary and not to be reproduced by any means Without written consent of West Penn Wire
Standard Lengths are 1000ft. The Jacket is sequentially footmarked. The information presented here is, to the best of our knowledge, is true and accurate. However, since conditions of use are beyond our control, all recommendations or suggestions are presented without guarantee or responsibility on our part. We disclaim all liability in connection with the use of information contained herein or otherwise.