Technical Data Sheet­Category 6 F/UTP Netw
Tested to 550Mhz
PART NUMBER:
DESCRIPTION: 23 AWG.- 4 PAIR Solid bare copper conductors, Shielded with an overall jacket.
NEC RATING: CMP
APPROVALS: C(UL)us or ETL Listed
APPLICATION: Indoor - Category 6 Applications- Ethernet, IP Cameras, Digital Integration, DVI,HDMI Meets or exceeds TIA/EIA 568C.2 Category 6 Specifications
ork
2833 West Chestnut Street
Washington, PA 15301
Toll Free: (800) 245-4964
Fax: (724) 222-6420
www.westpenn-wpw.com
Construction Parameters:
Conductor 23 AWG Bare Copper Stranding Solid Number of Conductors 8 (4 Pair) Insulation FEP Barrier Internal FlexWeb Core Separator Shield-Screen 100% Aluminum Foil -25% overlap Drain 24 AWG Solid Tin Core Separator Yes Jacket Material Plenum PVC Overall Cable Diameter 0.283'' Nom. Approximate Cable Weight 44 Lbs/1M' Nom. Flame Rating UL-NFPA 262
Electrical & Environmental Properties:
Operating Temperature Rating -20°C To +60°C Operating Voltage Rating 300 V RMS DC Resistance per Conductor @ 20deg C 20.4 ohms/1000ft Mutual Capacitance 14pf/ft Nominal Nominal Impedance 100 Ohms+/-15% (1-100Mhz) Velocity of Propagation 72% Nominal Delay Skew 30ns/100m MAX Standards TIA/EIA568-C.2 Insulation Colors 1.Blue/White-Blue, 2. Orange/White-Orange
3. Green/White-Green, 4. Brown/White-Brown Jacket Color Black RoHS Compliant Yes
Electrical Specifications:
Frequency: MHz 1 10 31.25 100 250 500 550 650 Insertion Loss: dB/100m 1.9 5.6 10.0 18.5 30.7 45.7 48.4 53.5 NEXT: dB/100m 74.3 59.3 51.9 44.3 38.3 33.8 33.2 32.1 ACR: dB/100m 72.3 53.3 41.2 24.5 5.5 -- -­PS-NEXT: dB/100m PS-ACR: dB/100m 70.3. 51.3 39.2 22.5 3.5 -- -­ELFEXT: PS-ELFEXT: dB/100m 68.0 48.0 38.1 28.0 20.0 14.0 -- RL:
Operating Temp -20 C to +60 C Storage Temp -20 C to +75 C Installation Temp 0 C to + 60 C Delay Skew 30ns/100m Max
dB/100m 70.0 50.0 40.1 30.0 22.0 16.0 --
dB 20 25 23.6 20.1 17.3 15.2 14.9 14.4
72.3 57.3 49.9 42.3 36.3 31.8 31.2 30.1
Mechanical Properties:
Max. Recommended Pull Tension 25 lbs. Min. Bend Radius (Install) 1.00”
Accessories:
Connectors: Jacks Connectors: Plugs
KJS458TL-C6C CN-111S90H34 – LOADING BAR –
106190 – LOADING BAR REQUIRES SPECIAL CRIMP TOOL
90170 – Kit: Includes 100 (106190)+12515C Crimp Tool+ 12360C External Ground Crimp Tool+ 15010C Strip Tool
Cable Boots:
CN-B0051 Black
Assemblies: Patch Panels:
C6CS-314GY-xxFB 24458S-C6C – 24 port Cat6 F/UTP Panel xx: 3,7,10,15,20,25 feet
CN-254246F-xx xx: 50,75,100,125,150 or Longer
Specification Issue Date: 10/13
This document is the property of West Penn Wire.
.
The information contained herein is considered Proprietary and not to be reproduced by any means Without written consent of West Penn Wire
Standard Lengths are 1000ft. The Jacket is sequentially footmarked. The information presented here is, to the best of our knowledge, is true and accurate. However, since conditions of use are beyond our control, all recommendations or suggestions are presented without guarantee or responsibility on our part. We disclaim all liability in connection with the use of information contained herein or otherwise.