Technical Data SheetCategory 6 F/UTP Netw
Tested to 550Mhz
PART NUMBER:
DESCRIPTION: 23 AWG.- 4 PAIR Solid bare copper conductors, Shielded with an overall jacket.
NEC RATING: CMP
APPROVALS: C(UL)us or ETL Listed
APPLICATION: Indoor - Category 6 Applications- Ethernet, IP Cameras, Digital Integration, DVI,HDMI
Meets or exceeds TIA/EIA 568C.2 Category 6 Specifications
ork
2833 West Chestnut Street
Washington, PA 15301
Toll Free: (800) 245-4964
Fax: (724) 222-6420
www.westpenn-wpw.com
254246F Replaces: M58183
Construction Parameters:
Conductor 23 AWG Bare Copper
Stranding Solid
Number of Conductors 8 (4 Pair)
Insulation FEP
Barrier Internal FlexWeb Core Separator
Shield-Screen 100% Aluminum Foil -25% overlap
Drain 24 AWG Solid Tin
Core Separator Yes
Jacket Material Plenum PVC
Overall Cable Diameter 0.283'' Nom.
Approximate Cable Weight 44 Lbs/1M' Nom.
Flame Rating UL-NFPA 262
Electrical & Environmental Properties:
Operating Temperature Rating -20°C To +60°C
Operating Voltage Rating 300 V RMS
DC Resistance per Conductor @ 20deg C 20.4 ohms/1000ft
Mutual Capacitance 14pf/ft Nominal
Nominal Impedance 100 Ohms+/-15% (1-100Mhz)
Velocity of Propagation 72% Nominal
Delay Skew 30ns/100m MAX
Standards TIA/EIA568-C.2
Insulation Colors 1.Blue/White-Blue, 2. Orange/White-Orange
3. Green/White-Green, 4. Brown/White-Brown
Jacket Color Black
RoHS Compliant Yes
Electrical Specifications:
Frequency: MHz 1 10 31.25 100 250 500 550 650
Insertion Loss: dB/100m 1.9 5.6 10.0 18.5 30.7 45.7 48.4 53.5
NEXT: dB/100m 74.3 59.3 51.9 44.3 38.3 33.8 33.2 32.1
ACR: dB/100m 72.3 53.3 41.2 24.5 5.5 -- -PS-NEXT: dB/100m
PS-ACR: dB/100m 70.3. 51.3 39.2 22.5 3.5 -- -ELFEXT:
PS-ELFEXT: dB/100m 68.0 48.0 38.1 28.0 20.0 14.0 --
RL:
Operating Temp -20 C to +60 C
Storage Temp -20 C to +75 C
Installation Temp 0 C to + 60 C
Delay Skew 30ns/100m Max
dB/100m 70.0 50.0 40.1 30.0 22.0 16.0 --
dB 20 25 23.6 20.1 17.3 15.2 14.9 14.4
72.3 57.3 49.9 42.3 36.3 31.8 31.2 30.1
Mechanical Properties:
Max. Recommended Pull Tension 25 lbs.
Min. Bend Radius (Install) 1.00”
Accessories:
Connectors: Jacks Connectors: Plugs
KJS458TL-C6C CN-111S90H34 – LOADING BAR –
106190 – LOADING BAR REQUIRES SPECIAL CRIMP TOOL
90170 – Kit: Includes 100 (106190)+12515C Crimp Tool+ 12360C
External Ground Crimp Tool+ 15010C Strip Tool
Cable Boots:
CN-B0051 – Black
Assemblies: Patch Panels:
C6CS-314GY-xxFB 24458S-C6C – 24 port Cat6 F/UTP Panel
xx: 3,7,10,15,20,25 feet
CN-254246F-xx
xx: 50,75,100,125,150 or Longer
Specification Issue Date: 10/13
This document is the property of West Penn Wire.
.
The information contained herein is considered
Proprietary and not to be reproduced by any means
Without written consent of West Penn Wire
Standard Lengths are 1000ft.
The Jacket is sequentially footmarked.
The information presented here is, to the best of our
knowledge, is true and accurate. However, since
conditions of use are beyond our control, all
recommendations or suggestions are presented
without guarantee or responsibility on our part. We
disclaim all liability in connection with the use of
information contained herein or otherwise.