Technical Data SheetPlenum Category 5E Net
work+ Power Pair
2833 West Chestnut Street
Washington, PA 15301
Toll Free: (800) 245-4964
Fax: (724) 222-6420
www.westpenn-wpw.com
PART NUMBER:
DESCR
NEC RATING: CMP
APPROVALS: (UL) C(UL) Listed or c(ETL)us Listed
APPLICATION: Indoor Plenum - Category 5E Applications- Ethernet, IP Cameras, Digital Integration
Meets TIA/EIA 568B.2 Category 5e Specifications with Power – Nurse Call –- GE
IPTION: Zip- Siamese Construction: 4 Pair Cat5E + 16/2 Unshielded – Overall Plenum Zip Jacket
254245162
Construction Parameters: Data Cable
Conductor 24 AWG Bare Copper
Stranding Solid
Number of Conductors 8 (4 Pair)
Insulation Flame Retardant Polyolefin - .008”
Shield None
Drain None
Construction Parameters: Power Cable
Conductor 16 AWG Bare Copper
Stranding Stranded 19x29
Number of Conductors 2
Insulation Plenum PVC - .010
Shield None
Drain None
Overall Construction: Zip (Siamese)
Jacket Material Plenum PVC - Flex
Overall Cable Diameter 0.380x.190 Nom. Approx.
Approximate Cable Weight 42 Lbs/1M' Nom.
Jacket Color Security Green
Flame Rating NFPA 262
Electrical & Environmental Properties: Data Cable
Operating Temperature Rating -20°C To +60°C
Operating Voltage Rating 300 V RMS
DC Resistance per Conductor @ 20deg C 9.38 Ohms/100m Nom.
Mutual Capacitance 14pf/ft Nominal
Nominal Impedance 100 Ohms+/-15% (1-100Mhz)
Velocity of Propagation 71% Nominal
Delay Skew 45ns/100m MAX
Standards TIA/EIA568-B.2
Insulation Colors 1.Blue/White-Blue, 2. Orange/White-Orange
3. Green/White-Green, 4. Brown/White-Brown
PART NUMBER: 254245162
Electrical & Environmental Properties: Power Cable
Operating Temperature Rating -20°C To +60°C
Operating Voltage Rating 300 V RMS
DC Resistance per Conductor @ 20deg C 4.2 Ohms/100m Nom.
Insulation Colors 1.Black 2. Red
Electrical Specifications: Data Cable
Frequency: MHz 1 10 25 100 200
Insertion Loss: dB/100m 1.8 5.8 9.3 19.6 28.8
NEXT: dB/100m 80 64 59 50 46
ACR: dB/100m 70.3 50.9 41.1 40.3 35.8
PS-NEXT:
PS-ACR: dB/100m 66.3 46.9 37.1 17.3 3.3
ELFEXT: dB/100m 67.8 47.8 39.8 27.8 21.8
PS-ELFEXT: dB/100m 64.8 25 36.8 24.8 18.8
RL:
Specification Issue Date: 10-201
This document is the property of West Penn Wire.
.
The information contained herein is considered
Proprietary and not to be reproduced by any means
Without written consent of West Penn Wire
dB/100m 73 58 52 43 40
dB 20 25 24.3 20.1 18
2
Standard Lengths are 1000ft.
The Jacket is sequentially footmarked.
The information presented here is, to the best of our
knowledge, is true and accurate. However, since
conditions of use are beyond our control, all
recommendations or suggestions are presented
without guarantee or responsibility on our part. We
disclaim all liability in connection with the use of
information contained herein or otherwise.