![](/html/45/451e/451ed40758272bf868e7e7df9b436b725e5074ca1cf9f44697b29dc3316d96a7/bg1.png)
Technical Data Sheet - Economy
RG59/U CCTV + Pow
PART NUMBER:
DESCRIPTION: RG59/U 20AWG Bare Copper, 95% Copper Alloy + 2 Conductor 18AWG – Siamese Construction
Plenum PVC Jacket
NEC RATING: CMP
APPROVALS: (UL) C(UL) or c(ETL)us Listed
APPLICATION: Indoor within ducts, plenums, and other spaces used for environmental air for (CCTV)
er Coaxial Cable Plenum
252815E
2833 West Chestnut Street
Washington, PA 15301
Toll Free: (800) 245-4964
Fax: (724) 222-6420
www.westpenn-cdt.com
Construction Parameters: Coaxial Cable
Conductor 20 AWG Bare Copper RG59/U
Stranding Solid
Insulation Material Foam FEP
Insulation Thickness 0.138'' Nom.
Shield 95 % Copper Alloy Braid
Electrical & Environmental Properties: Coaxial Cable
Temperature Rating -20deg C to 60deg C
Operating Voltage 300 V RMS
Max. Capacitance Between Conductors @ 1 KHz 16.2pf/ft Nom.
Nom. Velocity of Propagation 82%
Nom. Attenuation
Mhz db/100ft
1 .29
10 .68
50 1.80
100 2.52
400 5.30
700 9.8
1000 10.7
Construction Parameters: Power Pair
Conductor 18 AWG Bare Copper
Stranding 7x26
Insulation Material Plenum PVC
Insulation Thickness 0.010'' Nom.
Number of Conductors 2
Shield None
Drain None
Electrical & Environmental Properties: Power Pair
Temperature Rating -20°C To +60°C
Operating Voltage 300 V RMS
Max. Capacitance Between Conductors @ 1 KHz 30 pf/ft Nom.
DC Resistance per Conductor @ 20deg C 6.2 Ohms/1M' Nom.
Insulation Colors Black ,Red
Construction Parameters: Overall Cable
Jacket Material PVC Plenum
Overall Cable Diameter .198” x .465”
Jacket Colors Black
Flame Rating NFPA 262 Flame Test
RoHS Compliant Yes
![](/html/45/451e/451ed40758272bf868e7e7df9b436b725e5074ca1cf9f44697b29dc3316d96a7/bg2.png)
Mechanical Properties:
Max. Recommended Pull Tension 42 Lbs.
Min. Bend Radius (Install) 4.65
Connectors:
75ohm BNC Crimp CN-BM74-32
Compression BNC CN-BNC59MCV
Specification Issue Date: 4/12
This document is the property of West Penn Wire.
.
The information contained herein is considered
Proprietary and not to be reproduced by any means
Without written consent of West Penn Wire
Standard Lengths are 1000ft.
The Jacket is sequentially footmarked.
The information presented here is, to the best of our
knowledge, is true and accurate. However, since
conditions of use are beyond our control, all
recommendations or suggestions are presented
without guarantee or responsibility on our part. We
disclaim all liability in connection with the use of
information contained herein or otherwise.