![](/html/86/86e6/86e67590d79d77c1260faf39097121751e9a3ab58d3504f1d87ee6cae42c678a/bg1.png)
2833 West Chestnut Street
This document is the property of West Penn Wire.
Standard Lengths a re 1000ft.
Technical Data Sheet
Plenum Communication Cables
PART NUMBER:
DESCRIPTION: 10/2 Stranded bare copper conductors, unshielded with an overall jacket
NEC RATING: CL2P, NEC Article 725
APPROVALS: (UL) or (ETL)us Listed
APPLICATION: Cluster Speaker Cable- Class 2 Plenum
Construct ion Parameters:
Conductor 10 AWG Bare Copper
Stranding 65x28
Insulation Material Flouropolymer
Insulation Thickness 0.008” Nom.
Number of Conductors 2
Shield None
Drain None
Jacket Material Plenum PVC
Jacket Thickness 0.015” Nom.
Overall Cable Diameter 0.275'' Nom.
Approximate Cable Weigh t 90 Lbs/1M' Nom.
Flame Rating NFPA-262 Flame Test
Electrical & Environm e n tal Properties:
Temperature Rating -10°C To +60°C
Operating Voltage 150 V RMS
Max.Capacitance Between C onductors @ 1 KHz 34 pf/ft Nom.
DC Resistance per Conductor @ 20deg C 1.10 Ohms/1M' Nom.
Insulation Colors Black ,White
Jacket Color Ivory
RoHS Compliant --
Mechanical Properties:
Max. Recommended Pu ll Tension 248 Lbs.
Min. Bend Radius (Install) 2.7”
Specification Issu e Date: 7/06
.
The inform at i o n contained herein is considered
Proprietary and not to be reproduced by any means
Without written consent of West Penn Wire
25210
Washington, PA 15301
Toll Free: (800) 245-4964
Fax: (724) 222-6420
www.westpenn-wpw.com
The Jacket is sequentially footmarked.
The information presented here is, to the best of our
knowledge, is true and ac curate. Howev er , since
conditions of use are beyond our control, all
recommendations or suggestions are presented
without guarantee or resp onsibility on our part. We
disclaim all liability in connection with the use of
information contained herein or otherwise.