![](/html/7d/7db8/7db87e7be99ca99ea39e2e215b3ea4fb15f4d7cf43ebb6596b21b4faa693e89d/bg1.png)
2833 West Chestnut Street
This document is the property of West Penn Wire.
Standard Lengths a re 1000ft.
Technical Data Sheet
Communication Cables
PART NUMBER:
DESCRIPTION: 22/2 STRANDED BARE COPPER CONDUCTORS, UNSHIELDE D WITH AN OVERALL
NEC RATING: CMR, NEC Article 800
APPROVALS: (UL) C(UL) Listed or c(ETL)us Listed
APPLICATION: Indoor for: Intercom, Security, Sound, Audio, Background Music, and Power Limited Control
Construct ion Paramet ers:
Conductor 22 AWG Bare Copper
Stranding 7x30
Insulation Material Polypropylene
Insulation Thickness 0.008'' Nom.
Number of Conductors 2
Shield None
Drain None
Jacket Material PVC
Jacket Thickness 0.015'' Nom.
Overall Cable Diameter 0.120'' Nom.
Approximate Cable Weigh t 11 Lbs/1M' Nom.
Flame Rating UL 1666 Riser Flame Test
Electrical & Environm e n tal Properties:
Temperature Rating -20°C To +60°C
Operating Voltage 300 V RMS
Max.Capacitance Between C onductors @ 1 KHz 20 pf/ft Nom.
DC Resistance per Conductor @ 20deg C 17 Ohms/1M' Nom.
Insulation Colors Black ,Red
Jacket Color Gray, White
RoHS Compliant Yes
Mechanical Properties:
Max. Recommended Pu ll Tension 18.2 lbs.
Min. Bend Radius (Install) 1.3”
Specification Issu e Date: 1/14
.
The inform at i o n contained herein is cons i dered
Proprietary and not to be reproduced by any means
Without written consent of West Penn Wire
221
JACKET.
Circuits
Washington, PA 15301
Toll Free: (800) 245-4964
Fax: (724) 222-6420
www.westpenn-wpw.com
The Jacket is sequential ly footmarked.
The information presented here is, to the best of our
knowledge, is true and accurate. However, si n ce
conditions of use are beyond our control, all
recommendations or sugg estions are presented
without guarantee or resp onsibility on our pa r t. We
disclaim all liability in connection with the use of