Westinghouse 6695500, 6680800 Instruction Manual

Owner’s Manual
Guide d’utilisation Manual del Usuario
Instructions d'installation Appareil d'éclairage pour utilisation extérieure
Instrucciones para la insalación de la lámpara para exteriores
W-046
081011
Please write model number here for future reference: / Veuillez noter le numéro de mod­èle aux fins de référence ultérieure: / Por favor, incluya el número del modelo aquí para futura referencia:
ASSEMBLY INSTRUCTIONS FOR INDOOR LIGHT FIXTURE
Congratulations on your Westinghouse purchase. This fixture has been designed to give you many years of beauty and service. For questions and comments, please visit www.westinghouselighting. com/contact-us.
NOTE: Carefully unpack fixture and parts. Make sure all parts are included before discarding any packing materials (see figure 1).
WARRANTY INFORMATION
This Westinghouse Lighting Fixture is warranted against defects in material and workmanship for a period of Five Years from purchase date. This warranty is in lieu of all other warranties expressed or implied.
This warranty does not cover acts of nature such as lightning damage, or corrosion and discoloration of components, nor does it cover damages caused through abuse, improper installation, surges in electric current, or acts of third parties.
This warranty does not cover costs of removing and re-installing the light fixture. If this fixture fails for any reason covered by this warranty, simply return the fixture with a copy of
the original sales receipt, freight prepaid and Westinghouse Lighting, at its option, shall repair or replace the fixture or refund the purchase price.
WARNING ELECTRICAL SHOCK CAN RESULT IN SERIOUS INJURY.
Read and follow instructions exactly as shown. If instructions are unclear, do not proceed. Contact a qualified electrician. Read all instructions before beginning. Proper wiring is essential for safe operation of this fix­ture. When cutting or drilling into walls or ceilings, do not damage electri­cal wiring, gas lines, or water lines. If any of the fixture or wiring compo­nents are damaged, do not install fixture. Return to place of purchase.
For fixtures provided with 75° C or 90° C supply wire warning only. (These warnings are provided on the U.L. label and on the fixture carton.) Risk of fire. Most dwellings built before 1985 have supply wires rated 60° C. Consult a qualified electrician before installing.
NOTE: For fixture employing a grounded convenience outlet. This fixture employs a grounded type receptacle and is not intended for connection to a two wire ungrounded source of supply.
Applicable only to portable lamps: To reduce the risk of electrical shock, all portable lamps have a polarized plug (one blade is wider than the other). This plug will fit into a polarized outlet only one way. If plug does not fit, contact a qualified electrician. Never use with an extension cord unless plug can be fully plugged into the extension cord. Do not alter the plug.
fit, reverse the plug. If it still does not
2
MOUNTING INSTRUCTIONS
CAUTION: For fixtures labeled for outdoor and wet location use, provide a water-tight seal between the fixture and the mounting surface by using silicone or similar caulking.
NOTE: Underwriters Laboratories (UL) does not require all fixtures to have ground wires. These fixtures meet all UL specifications.
1. Before wiring, place fixture fitter over the top of the lamp post making sure the fixture is fully seated on the post and positioned just as you would like the complete unit to be presented.
2. Using a pencil, mark the center of each mounting hole on the lamp post through pre-existing mounting holes on the fixture.
3. Remove the fixture from the lamp post making sure each of the marks you made are easily identified.
4. Drill a small pilot hole through the center of each mark making sure the size of the pilot hole is approximately 1/2 the diameter of the mounting screw provided with the fixture. This will allow the mounting screw to grab the post
and properly secure the fixture.
5. Follow the instructions within this manual for properwiring.
6. Once wiring is complete, slide the fitter of the fixture onto the top of the lamp post making sure to align each of the mounting holes.
7. Secure the fixture to the post with the mounting screws provided with the fixture.
WIRING INSTRUCTIONS
WARNING: Never connect ground wire to black or white power supply wires.
1. Turn off power at circuit box to avoid possible electric shock.
2. Identify color coding of fixture wires (see fig. 1).
3. To connect wires, take black fixture wire (group A from fig. 1) and place evenly against black outlet boxwire. Do not twist wires.
4. Fit wire connector overwires and twist until there is a firm connection. If wire connector easily comes off, reattach and check again for a firm connection.
5. Repeat steps 3 and 4 with the white (group B from fig. 1) fixture and outlet box wires.
6. To connect ground wires, follow steps 4 and 5 for the fixture and outlet box ground wires.
FIGURE 1.
GROUP A: GROUP B:
BLACK
WHITE OR GREY WITH TRACER
BROWN, GOLD OR BLACK WITHOUT TRACER
NOTE: When parallel wire (SPT I & SPT II) is used; the neutral wire is square shaped and ridged, and the hot wire will be round in shape and smooth. (See below.)
CONNECT TO BLACK HOUSE WIRE
WHITE
WHITE OR GREY WITHOUT TRACER
BROWN, GOLD OR BLACK WITH TRACER
CONNECT TO WHITE HOUSE WIRE
3
WARNING Turn off electricity to the
mounting site before beginning installation.
Mounting instructions must be followed exactly as shown for the fixture to be safely supported.
FIGURE 2.
*FIXTURE FITTER (B)
FIGURE 3.
*FIXTURE FITTER (A)
CONVENIENCE OUTLET (D)
COVER
GND
GND
WHT
WHT
BLK
RED
WHT
BLK
BLK
PHOTO ELECTRIC CONTROL (A)
GND
BLKBLK
WHT
WHT
GND
*SUPPLY
WHT
BLK
GND
PLATE (C)
SHEET METAL SCREWS (E)
WIRE
*SUPPLY
WIRE
POST (C)
*NOT SUPPLIED
POST (B)
*NOT SUPPLIED
PHOTO ELECTRIC CONTROL WIRING (FIGURE 2.)
CAUTION: Do not exceed 1000 watts for photoelectric control. NOTE: When connecting wires, loop wires below the photocell to avoid water accumulation.
1. To connect wires, take white fixture wire from group A in fig. 1 and connect to red photoelectric control (A from fig. 2) wire by following steps 3, 4, and 5 under wiring instructions (see fig 1).
2. Repeat steps 3, 4, and 5 under wiring instructions with the black fixture and outlet box wires (see fig. 1).
3. To connect ground wires, follow steps 4 and 5 from wiring instructions for fixture and outlet box ground wires.
4. Slide fitter (B from fig. 2) onto post (C from fig. 2) and secure into place.
OUTLET WIRING (FIGURE 3.)
1. To connect wires, take white fixture wire from group A in fig. 1 and connect to red photoelectric control wire by following steps 3, 4, and 5 under wiring instructions (see fig 1).
2. Repeat steps 3, 4, and 5 under wiring instructions with the black fixture and outlet box wires.
3. To connect ground wires, follow steps 4 and 5 from wiring instructions for fixture and outlet box ground wires.
4. Slide fitter (A from fig. 3) onto post (B from fig. 3) and secure into place.
5. Place cover plate (C from fig. 3) on flat area of post (B from fig. 3) over convenience outlet (D from fig. 3) and secure into place with sheet metal screws (E from fig. 3).
Line art shown may not exactly match the fixture enclosed. However, the installation instructions do apply to this fixture.