ASSEMBLY INSTRUCTIONS FOR OUTDOOR LIGHT FIXTURE
Congratulations on yourWestinghouse purchase. This fixture has been designed to give you
many years of beauty and service. Please email questions and comments to:
catalogroom@westinghouselighting.com.
NOTE: Carefully unpack fixture and parts. Make sure all parts are included before
discarding any packing materials (see figure 1).
WARRANTY INFORMATION
This Westinghouse Lighting Fixture is warranted against defects in material and workmanship for
a period of Five Years from purchase date. This warranty is in lieu of all other
warranties expressed or implied.
This warranty does not cover acts of nature such as lightning damage, or corrosion and
discoloration of components, nor does it cover damages caused through abuse, improper
installation, surges in electric current, or acts of third parties.
This warranty does not cover broken glass. If fixture is received with broken glass, please call
Westinghouse Lighting for free replacement.
This warranty does not cover costs of removing and re-installing the light fixture.
If this fixture fails for any reason covered by this warranty, simply return the fixture with a copy of
the original sales receipt, freight prepaid and Westinghouse Lighting, at its option, shall repair or
replace the fixture or refund the purchase price.
WARNING
NOTE: DO NOT INSTALL ON APOST THAT RESULTS
IN AVERTICAL RISE OF 25 FEET OR HIGHER.
WARNING ELECTRICAL SHOCK CAN RESULT IN SERIOUS INJURY.
Read and follow instructions exactly as shown. If instructions are unclear,
do not proceed. Contact a qualified electrician. Read all instructions
before beginning. Proper wiring is essential for safe operation of this fixture. When cutting or drilling into walls or ceilings, do not damage electrical wiring, gas lines, or water lines. If any of the fixture or wiring components are damaged, do not install fixture. Return to place of purchase.
For fixtures provided with 75° C or 90° C supply wire warning only. (These
warnings are provided on the U.L. label and on the fixture carton.) Risk of
fire. Most dwellings built before 1985 have supply wires rated 60° C.
Consult a qualified electrician before installing.
NOTE: For fixture employing a grounded convenience outlet. This fixture
employs a grounded type receptacle and is not intended for connection to
a two wire ungrounded source of supply.
Applicable only to portable lamps:
To reduce the risk of electrical shock, all portable lamps have a polarized
plug (one blade is wider than the other). This plug will fit into a polarized
outlet only one way. If plug does not fit, reverse the plug. If it still does not
fit, contact a qualified electrician. Never use with an extension cord unless
plug can be fully plugged into the extension cord. Do not alter the plug.
2

FIGURE 1.
PANELS (F)
GLASS
SLEEVE (I)
(if applicable)
CAGE (G)
FITTER (A)
ROOF (E)
CAGE (G)
Line art shown may not exactly match the fixture enclosed.
However, the installation instructions do apply to this fixture.
POST (B)
3
SCREW (D)

MOUNTING AND WIRING INSTRUCTIONS
CAUTION: For fixtures labeled for outdoor and wet location use, provide a water-tight seal
between the fixture and the mounting surface by using silicone or similar caulking.
NOTE: Underwriters Laboratories (UL) does not require all fixtures to have ground wires. These
fixtures meet all UL specifications.
1. Turn off power at circuit box to avoid possible electric shock.
NOTE: If post does not have mounting holes, follow step 2. Otherwise, skip step 2 and proceed
with step 3.
2. Place fitter (A) over post (B) (see figure1). Mark post using fitter holes as a guide. Remove
fitter, drill
3. Pull wires up from post (B) and thread through fitter (A).
4. Identify color coding of fixture wires (see figure 2 on page 11).
5. To connect wires, take black fixture wire (group A from figure 2) and place evenly against
black post wire. Do not twist wires.
6. Fit wire connector over wires and twist until there is a firm connection. If wire connector
easily comes off, reattach wire connector and check again for a firm connection.
7. Repeat steps 5 and 6 with the white (group B from figure 2) fixture wire and post wires.
8. Place ground wire from fixture evenly against ground wire (metal or green wire) from
post (B).
9. Repeat step 6 for ground wires.
1
/8” hole through post at each mark.
FIXTURE ASSEMBLY INSTRUCTIONS
1. Place fitter (A) over post (B) (see figure 1).
2. Secure with screws (D).
3. Secure roof (E) to cage (G) by lining up the internal hinge mechanism with two pins
inside of roof (E). Note: cage (G) may need to be squeezed to line up the two pins.
4. Install panels (F) (textured side in) into cage (G).
5. Install lamp(s). Do not exceed recommended wattage.
6. Install glass sleeve (I) over lamp, if applicable.
7. Turn on power at circuit box.
4