SPECIFICATION SHEET
T8 Direct Install LED Lamp†
Operates with Applicable Ballast
Item Number 03652
Specifications
Energy Used (Watts) ................................................... 22
Domestic Code .............................................................. LED 22T8/48”/35 Direct Install
Volts ................................................................................... 144
Brightness (Lumens) ................................................... 2200
Average Rated Hours .................................................. 50,000
Life (in years)*...................................... .......................... 45.6
Light Appearance (Kelvin) ........................................ 3500
CRI ...................................................................................... 85
Efficacy (LPW) ............................................................... 100
Number of LED Modules ............................................ 120
Minimum Starting Temperature ............................... -20°C/-4°F
Estimated Yearly Energy Cost**...... ........................ $2.65
Package Type ................................................................ Sleeve
† Dimmable when used with applicable ballast.
Physical Characteristics
Finish .................................................................................... Cool White
Base ...................................................................................... G13
MOL ...................................................................................... 48"
NO
mercury
Limited Warranty
This lamp is warranted to be free from defects in material and workmanship for 3 years (based on using 3 hours per day).
Warning
• Turn power off before inspection, installation, or removal.
• Risk of electric shock - Do not use where exposed to water or weather.
• Not for use in totally enclosed luminaires.
• Do not open – no user serviceable parts inside.
• This device is not intended for use with emergency exit luminaires or emergency exit lights.
• This device complies with Part 15 of the FCC rules and has been tested and found to comply with the limits for a Class B digital device. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. Any changes or modifications not expressly approved by the manufacturer could void the user's authority to operate the equipment.
* Based on 3 hrs./day
** Based on 3 hrs./day 11¢/kWh - Cost depends on rates and use.
See reverse side for ballast compatibility.
Compatible Ballasts
One Lamp, Instant Start, Normal Ballast Factor
Manufacturer Series/Model
DOO YOUNG DY132NS
HALCO EP132IS/MV/MC
PHILIPS ICN-1P32-N, ICN-132-MC
Two Lamps, Instant Start, Normal Ballast Factor
Manufacturer Series/Model
ADVANCE REL-2P32-SC
DAMAR 1688A
ESPEN VE232MVHIP
GE GE-232-120-N, GE-232MAX-N/ULTRA
HALCO
HOWARD INDUSTRIES
HUAFENG ENI-T8-32-P2SC-N
KEYSTONE KTEB-232-UV-IS-N-P
ROBERTSON 15L232T8120
STANDARD EP232T8IS120/N/AS
SUNPARK U-2/32IS, U-2/32ISE
SYLVANIA QHE 2x32T8/UNV ISN-SC
UNIVERSAL
Two Lamps, Instant Start, Low Ballast Factor
Manufacturer Series/Model
GE GE-232-MVPS-L
HALCO EP232IS/L/MV/HE
STANDARD EP232PI120L
SUNPARK U-2/32ISE LBF
Two Lamps, Instant Start, High Ballast Factor
Manufacturer Series/Model
GE GE-232-MVPS-H
HALCO EP232IS/H/MV/HE
PHILIPS ICN-2M32-MC
PREMIUM BB-T8/UVH-2x32
STANDARD
SUNPARK U-2/32IS HBF, U-2/32ISE HBF
Two Lamps, Instant Start,
Normal Ballast Factor, 347V
Manufacturer Series/Model
PHILIPS GOPA-2P32-SC
STANDARD E232T8IS347/N/BULK
Two Lamps, Instant Start, Low Ballast Factor, 347V
Manufacturer Series/Model
STANDARD E232T8IS347/L/BULK
EP232IS/MV/MC
EP2/32IS/MV/MC/HE
B232PUNVHE-B, B232IUNVHP-N
E232T8IS347/H/90C, E232T8IS120/H/90C
Three Lamps, Instant Start, Normal Ballast Factor
Manufacturer Series/Model
FULHAM WH3-120-L, WHCG3-120-T8-IS
GE GE-332MV-N
HALCO EP332IS/MV/MC
KEYSTONE KTEB-332-UV-IS-N-P
SUNPARK U-3/32IS, U-3/32ISE
VISONATOR VEB3x32UI
Three Lamps, Instant Start, Low Ballast Factor
Manufacturer Series/Model
HALCO EP332IS/L/MV/HE
SUNPARK U-3/32ISE LBF
Three Lamps, Instant Start, High Ballast Factor
Manufacturer Series/Model
SUNPARK U-3/32IS HBF, U-3/32ISE HBF
Four Lamps, Instant Start, Normal Ballast Factor
Manufacturer Series/Model
ESPEN VE432MVHIP
GE GE-432-277-N, GE-432-120-N
GREEN HILL GH4P32ISUNV
HALCO EP432IS/MV/MC
HOWARD INDUSTRIES
KEYSTONE KTEB-432-UV-IS-N-P
PHILIPS IPO-4P32-LW-N
STANDARD
SUNPARK U-4/32IS, U-4/32ISE
SYLVANIA QTP 4x32T8/UNV ISN-SC
UNIVERSAL B432IUNVHP-A
EP4/32IS/MV/MC/HE
E432T8IS120/N/AS/BULK, E432T8IS347/N/BULK
Four Lamps, Instant Start, Low Ballast Factor
Manufacturer Series/Model
HALCO EP432IS/L/MV/HE
STANDARD
SUNPARK U-4/32ISE LBF
E432T8IS120/L/AS/BULK, E432T8IS347/L/BULK
Four Lamps, Instant Start, High Ballast Factor
Manufacturer Series/Model
STANDARD E432T8IS120/H
SUNPARK U-4/32IS HBF, U-4/32ISE HBF
Two Lamps, Program Rapid Start,
Normal Ballast Factor
Manufacturer Series/Model
GE GE-232-120-PS-N, GE240RS-MV-N-DIY
ROBERTSON RSW232T8120
Specifications are subject to change without notice, please visit www.westinghouselighting.com for latest information.
Call 1-800-999-2226 or visit www.westinghouselighting.com.
, WESTINGHOUSE, and INNOVATION YOU CAN BE SURE OF are trademarks of Westinghouse Electric Corporation.
Used under license by Westinghouse Lighting. All Rights Reserved.
Two Lamps, Program Rapid Start,
Normal Ballast Factor, Triac Dimmer
Manufacturer Series/Model
PHILIPS REZ-2S32-SC
2015 WESTINGHOUSE LIGHTING / 0115 / 291