Agency approvals and standards compliance
Type Approval / Compliance
EMC EN 61000-6-2, Immunity industrial environments
EN 61000-6-31, Emission residential environments
EN 61000-6-42, Emission industrial environments
E-Mark, Road Vehicles, 10R-04 7216
3
Safety EN/IEC 60950-1, IT Equipment
UL 60950-1, IT Equipment 1st Edition
4
Marine DNV GL rules for classification – Ships and offshore units
5
Note 1 _ Applicable only for 3644-x001
2 _ Applicable only for 3644-0019, 3644-002x and 3644-003x
3
_ Applicable only for 3644-6001
4
– Applicable only for 3644-0001
5
– Applicable only for 3644-0001, 3644-0022 , 3644-0023, 3644-0025,
3644-0032, 3644-0033, 3644-0035
Article number, model and description
Article Model Description
3644-0001 SDW-550 10/100Base-T/TX: 5 ports
3644-6001 SDW-550 E-mark 10/100Base-T/TX: 5 ports
3644-0015 SDW-550B 10/100Base-T/TX: 5 ports
3644-0019 SDW-532-MM-SC2-SM-SC15 10/100Base-T/TX: 3 ports 100Base-FX: 2 port
3644-0020 SDW-541-MM-SC2 10/100Base-T/TX: 4 ports 100Base-FX: 1 port
3644-0021 SDW-541-MM-ST2 10/100Base-T/TX: 4 ports 100Base-FX: 1 port
3644-0022 SDW-541-SM-LC15 10/100Base-T/TX: 4 ports 100Base-FX: 1 port
3644-0023 SDW-541-MM-LC2 10/100Base-T/TX: 4 ports 100Base-FX: 1 port
3644-0024 SDW-541-SM-SC15 10/100Base-T/TX: 4 ports 100Base-FX: 1 port
3644-0025 SDW-541-SM-LC40 10/100Base-T/TX: 4 ports 100Base-FX: 1 port
3644-0030 SDW-532-MM-SC2 10/100Base-T/TX: 3 ports 100Base-FX: 2 port
3644-0031 SDW-532-MM-ST2 10/100Base-T/TX: 3 ports 100Base-FX: 2 port
3644-0032 SDW-532-SM-LC15 10/100Base-T/TX: 3 ports 100Base-FX: 2 port
3644-0033 SDW-532-MM-LC2 10/100Base-T/TX: 3 ports 100Base-FX: 2 port
3644-0034 SDW-532-SM-SC15 10/100Base-T/TX: 3 ports 100Base-FX: 2 port
3644-0035 SDW-532-SM-LC40 10/100Base-T/TX: 3 ports 100Base-FX: 2 port
Corrosive
environment
Notice:
This product has been successfully tested in a corrosion test according to
IEC 60068-2-60, method 3. This means that the product meets the requirements
to be placed in an environment classified as ISA-S71.04 class G3.
Note! If the product is placed in a corrosive environment, it is important that all
unused connector sockets are protected with a suitable plug in order to avoid
corrosion attacks on the gold plated pins in connectors.