Westermo SDW-541-SM-SC15, SDW-541-MM-SC2, SDW-541-MM-ST2, SDW-541-SM-LC15, SDW-532-MM-CS2 User Manual

...
Page 1
Industrial Ethernet
5-port Switch
www.westermo.com
©
Westermo Teleindustri AB • 2004 • REV.A
User Guide
6644-2211
SERIES
Page 2
2 6644-2211
Contents
1. Description .................................................................................................................................................................................................... 3
2. Safety ........................................................................................................................................................................................................................ 4
3. Approvals .......................................................................................................................................................................................................... 4
3.1 Declaration of Conformity ................................................................................................................................................... 5
4. Specification ........................................................................................................................................................................................ 6–7
5. Maintenance ................................................................................................................................................................................................ 8
6. Installation ...................................................................................................................................................................................................... 8
6.1 Mounting / Removal ....................................................................................................................................................................... 8
6.2 Connections ............................................................................................................................................................................................. 9
6.2.1 Power .............................................................................................................................................................................................. 10
6.2.2 TX ....................................................................................................................................................................................................... 10
6.2.3 FX SC Multi- or single mode (optional) ........................................................................................... 10
6.2.4 FX ST Multi mode (optional) ......................................................................................................................... 10
6.2.5 FX LC Single mode (optional) ...................................................................................................................... 10
6.3 DIP switch settings SDW-550 ........................................................................................................................... 11–12
6.4 DIP switch settings SDW-541 and SDW-532 ................................................................................ 13–14
6.5 LED indicators .................................................................................................................................................................................. 15
Page 3
36644-2211
1. Description
The SDW-500 is a series of Industrial Ethernet 5-port switches. Several variations are available ranging from a version with five RJ-45 TX (copper) ports
to versions having two FX (fibre) and three TX ports. All TX ports support auto-negotiation, but DIP-switches also allow speed and duplex
configuration of any individual TX port. It is also possible to set up one port to monitor traffic to/from the switch.
The SDW-500 series has been designed to meet high industrial specifications, providing very high dependability in harsh environmental conditions.
Features:
… Flexible mix of TX (copper) and FX (fibre) interface … TX shields individually isolated … Wide DC power range 12–48 VDC … Wide temperature range … Redundant power … Automatic MDI/MDI-X crossover … LED indicators for Power, Speed, Duplex, Link and Traffic … Port monitoring … 35 mm DIN rail mounting … SC, ST and LC fibre interface … Multi (MM) and single mode (SM) fibre
Example of applications are:
… 5-port switch … Fibre to copper converter … Ethernet isolator, for STP network
Page 4
4 6644-2211
3. Approvals
Conformity with the Directive 73/23/EEC Low Voltage Directive – LVD has been assessed by application of the standard EN 60 950.
Conformity with the Directive 89/336/EEC Electromagnetic Compatibility (EMC) has been assessed by application of standards EN 61000-6-2 (industrial immunity) and EN 61000-6-3 (residential emission) and EN61000-6-4 (Industrial emission).
2. Safety
General:
Before using this unit, read this manual completely and gather all information on the unit. Make sure that you understand it fully. Check that your application does not exceed the safe operating specifications for this unit.
Before installation, maintenance or modification work:
Prevent damage to internal electronics from electrostatic discharges (ESD) by discharging your body to a grounding point (e.g. use of wrist strap).
Prevent access to hazardous voltages by disconnecting the unit from AC/DC mains supply and all other electrical connections.
Installation:
This unit should only be installed by qualified personnel.
This unit should only be installed in a “restricted access area”, for example a lockable cabinet where access is restricted to service personnel only.
This unit is intended for permanent connection to the AC/DC mains supply.
The power supply wiring must be sufficiently fused, and if necessary it must be possible to disconnect manually from the AC/DC mains supply. Ensure compliance to national installation regulations.
Units with the rated voltage exceeding 42.4 V peak or 60 VDC, are defined as class I equipment with a protective earthing conductor terminal.
Units with the rated voltage up to 42.4 V peak or 60 VDC, are defined as class III equipment and shall be separated from hazardous voltage by double or reinforced isolation.
This unit uses convection cooling.To avoid obstructing the air flow around the unit, follow the spacing recommendations (see Installation section).
!
!
!
Page 5
56644-2211
3.1 Declaration of Conformity
Westermo Teleindustri AB
Declaration of conformity
The manufacturer Westermo Teleindustri AB
SE-640 40 Stora Sundby, Sweden
Herewith declares that the product(s)
Type of product Model Art no Installation manual
DIN-rail SDW-550 LV 3644-0010 6644-2211 DIN-rail SDW-532-MM-SC2-SM-SC15 LV 3644-0019 6644-2211 DIN-rail SDW-541-MM-SC2 LV 3644-0020 6644-2211 DIN-rail SDW-541-MM-ST2 LV 3644-0021 6644-2211 DIN-rail SDW-541-SM-LC15 LV 3644-0022 6644-2211 DIN-rail SDW-541-SM-SC15 LV 3644-0024 6644-2211 DIN-rail SDW-532-2MM-SC2 LV 3644-0030 6644-2211 DIN-rail SDW-532-2MM-ST2 LV 3644-0031 6644-2211 DIN-rail SDW-532-2SM-LC15 LV 3644-0032 6644-2211 DIN-rail
SDW-532-2SM-SC15
LV 3644-0034 6644-2211
is in conformity with the following EC directive(s).
No Short name
89/336/EEG Electromagnetic Compatibility (EMC)
References of standards applied for this EC declaration of conformity.
No Title Issue
EN 61000-6-2 Immunity for industrial environments 2 (2001) EN 61000-6-3 Emission standard for residential, commercial and
1 (2001)
light-industrial environments (3644-0010)
EN 61000-6-4 Emission standard for industrial environments (3644-
1 (2001)
0020 and 3644-0030)
The last two digits of the year in which the CE marking was affixed: 04
Hans Levin Technical Manager 15th December2004
Postadress/Postal address Tel. Telefax Postgiro Bankgiro Corp. identity number Registered office
S-640 40 Stora Sundby 016-428000 016-428001 52 72 79-4 5671-5550 556361-2604 Eskilstuna
Sweden Int+46 16428000 Int+46 16428001
Org.nr/
Page 6
6 6644-2211
4. Specification
SDW-500 series
Rated voltage 12–48 VDC, polarity protected Operating voltage 9.6 – 57.6 VDC Rated current @12 VDC power input
SDW-550 320 mA SDW-541-MM-SC2 450 mA SDW-541-MM-ST2 450 mA SDW-541-SM-LC15 350 mA SDW-541-SM-SC15 350 mA SDW-532-2MM-SC2 600 mA SDW-532-2MM-ST2 600 mA SDW-532-2SM-LC15 450 mA SDW-532-2SM-SC15 450 mA
SDW-532-MM-SC2-SM-SC15 450 mA Rated frequency DC Connection Detachable screw terminal Connector size 0.2 – 2.5 mm
2
(AWG 24-12)
Power interface
Ethernet TX Interface
Electrical specification IEEE std 802.3. 2000 edition Data rate 10 Mbit/s or 100 Mbit/s, manual or auto Duplex Full or half, manual or auto Connection RJ-45, shielded Circuit type TNV-1 Transmission range 100 m
Ethernet FX Interface
Fibre optic specification IEEE std 802.3. 2000 edition, multi or single mode, 1300 nm Data rate 100 Mbit/s Duplex Full Connection SC, ST, or LC Transmission range 2 or 15 km
Mechanical
Dimension (W x H x D) 35 x 121 x 119 mm Weight 0.2 kg Mounting DIN-rail Degree of protection IP21
Page 7
76644-2211
Isolation between interfaces
Power Interface to all other 2.8 kV DC 2.0 kV RMS @ 50 Hz and 60 s duration TX signal Interface to all other 2.1 kV DC 1.5 kV RMS @ 50 Hz and 60 s duration TX shield Interface to all other 1.5 kV DC 1.0 kV RMS @ 50 Hz and 60 s duration
Environmental
Temperature, operating –25 to +70°C (SDW-550),
–25 to +65°C (SDW-541),
–25 to +60°C (SDW-532) Temperature, storage and transportation –25 to +70°C Relative humidity, operating 5 to 95% (non-condensing) Relative humidity, storage and transportation 5 to 95% (condensation allowed outside packaging)
Configuration
Auto configured (auto-negotiation) or manually setting of speed and duplex of individual TX port, by DIP-switches. Port mirror function is possible to set with DIP-switch. With the port mirror function active the switch will copy all outgoing traffic to port 1. This can be used to monitor all traffic going out from the switch. Packets may be discarded if the total throughput exceeds the port speed of port 1.
Page 8
8 6644-2211
5. Maintenance
No maintenance is required, as long as the unit is used as intended within the specified conditions.
6. Installation
6.1 Mounting / Removal
Before mounting or removing the unit:
Prevent damage to internal electronics from electrostatic discharges (ESD) by discharging your body to a grounding point (e.g. use of wrist strap).
Prevent access to hazardous voltages by disconnecting the unit from AC/DC mains supply and all other electrical connections.
Mounting
This unit should be mounted on 35 mm DIN-rail which is horizon­tally mounted on a wall or cabinet backplate.
This unit uses convection cooling.To avoid obstructing the airflow around the unit, use the following spacing rules. Recommended spacing 25 mm (1.0 inch) above/below and 10 mm (0.4 inches) left/right the unit.
Snap on mounting, see figure
Removal
Press down the black support at the back of the unit, see figure.
10 mm *
(0.4 inches)
25 mm
25 mm
* Spacing (left/right) recommended
for full operating temperature range
!
CLICK!
Page 9
96644-2211
6.2 Connections
Power connection
Network Fibre connection or RJ-45 connection
Network RJ-45 connection
LED indicators
Available models:
… SDW-550 10/100Base-T/TX: 5 ports … SDW-541 10/100Base-T/TX: 4 ports 100Base-FX: 1 port … SDW-532 10/100Base-T/TX: 3 ports 100Base-FX: 2 ports
NOTE! SDW-532-MM-SC2-SM-SC15
Port 4: SC Single mode 15 km connector Port 5: SC Multi mode 2 km connector
Page 10
10 6644-2211
6.2.1 Power
The SDW-500 series supports redundant power connection. The positive input are +VA and +VB, the negative input for both supplies are COM. The power is drawn from the input with the highest voltage.
6.2.3 FX SC Multi- or single mode (optional)
Ethernet FX connection. 1300 nm multi- or singlemode fibre tranceiver with SC-connector. The dust protection plug shall be mounted when no fibre is connected.
6.2.2 TX
Ethernet TX connection (RJ-45 connector), automatic MDI/MDI-X crossover.
Contact Signal Name Direction Description/Remark
1 TD+ In/Out Transmitted/Received data
2 TD– In/Out Transmitted/Received data
3 RD+ In/Out Transmitted/Received data
4
5
6 RD– In/Out Transmitted/Received data
7
8
Shield HF-connected
CAT 5 cable is recommended. Unshielded (UTP) or shielded (STP) connector might be used.
3-pos screw terminal Description
1 COM
2+VA
3 +VB
6.2.5. FX LC Single mode (optional)
Ethernet FX connection. 1300 nm singlemode fibre transceiver with LC-connector. The dust protection plug shall be mounted when no fibre is connected.
6.2.4. FX ST Multi mode (optional)
Ethernet FX connection. 1300 nm multi mode fibre tranceiver with ST-connector. The dust protection plugs shall be mounted when no fibre is connected.
12 3
8 7
6
5 4
3 2 1
Page 11
116644-2211
6.3 DIP switch settings SDW-550
DIP-switches are accessible under the lid on top of the unit. DIP-switches are used to configure the unit.
Warning!
Prevent damage to internal electronics from electrostatic discharges (ESD) by discharging your body to a grounding point (e.g. use of wrist strap), before the lid on top/front of the unit is removed.
Warning! Do not open connected equipment.
Prevent access to hazardous voltages by disconnecting the unit from AC/DC mains supply and all other electrical connections.
NOTE
When configuration via DIP-switches, the settings of DIP-switches configure the unit only after a reboot (power off/on).
To be observe when the DIP-switches will be configured
… Speed and duplex setting only valid when auto-negotiation is disabled. … When monitoring selected all outgoing packets from the switch is also copied to the
port 1.
… If auto-negotiation and auto MDI/MDI-X disabled all TX ports support MDI-X
configuration.
!
!
Page 12
12 6644-2211
S1
S2
Port 3 settings
ON
12345678
S1
Auto-negotiation and auto MDI/MDI-X disabled
ON
12345678
S1
Auto-negotiation and auto MDI/MDI-X enabled
ON
12345678
S1
10 Mbit/s speed selected
ON
12345678
S1
100 Mbit/s speed selected
ON
12345678
S2
Half duplex selected
ON
12345678
S2
Full duplex selected
Port 1 settings
ON
12345678
S1
Auto-negotiation and auto MDI/MDI-X disabled
ON
12345678
S1
Auto-negotiation and auto MDI/MDI-X enabled
ON
12345678
S1
10 Mbit/s speed selected
ON
12345678
S1
100 Mbit/s speed selected
ON
12345678
S1
Half duplex selected
ON
12345678
S1
Full duplex selected
Port 2 settings
ON
12345678
S1
Auto-negotiation and auto MDI/MDI-X disabled
ON
12345678
S1
Auto-negotiation and auto MDI/MDI-X enabled
ON
12345678
S1
10 Mbit/s speed selected
ON
12345678
S1
100 Mbit/s speed selected
ON
12345678
S1
Half duplex selected
ON
12345678
S1
Full duplex selected
Port 4 settings
ON
12345678
S2
Auto-negotiation and auto MDI/MDI-X disabled
ON
12345678
S2
Auto-negotiation and auto MDI/MDI-X enabled
ON
12345678
S2
10 Mbit/s speed selected
ON
12345678
S2
100 Mbit/s speed selected
ON
12345678
S2
Half duplex selected
ON
12345678
S2
Full duplex selected
Port 5 settings
ON
12345678
S2
Auto-negotiation and auto MDI/MDI-X disabled
ON
12345678
S2
Auto-negotiation and auto MDI/MDI-X enabled
ON
12345678
S2
10 Mbit/s speed selected
ON
12345678
S2
100 Mbit/s speed selected
ON
12345678
S2
Half duplex selected
ON
12345678
S2
Full duplex selected
Port mirroring settings
ON
12345678
S2
No monitoring selected
ON
12345678
S2
Monitoring selected
Factory settings
ON
12345678
S1
ON
12345678
S2
Page 13
136644-2211
6.4 DIP switch settings SDW-541 and SDW-532
DIP-switches are accessible under the lid on top of the unit. DIP-switches are used to configure the unit.
Warning!
Prevent damage to internal electronics from electrostatic discharges (ESD) by discharging your body to a grounding point (e.g. use of wrist strap), before the lid on top/front of the unit is removed.
Warning! Do not open connected equipment.
Prevent access to hazardous voltages by disconnecting the unit from AC/DC mains supply and all other electrical connections.
NOTE
When configuration via DIP-switches, the settings of DIP-switches configure the unit only after a reboot (power off/on).
To be observe when the DIP-switches will be configured
… Speed and duplex setting only valid when auto-negotiation is disabled. … When monitoring selected all outgoing packets from the switch is also copied to the
port 1. … Speed and duplex switch settings are ignored for FX ports. … If auto-negotiation and auto MDI/MDI-X disabled all TX ports support MDI-X
configuration.
!
!
Page 14
14 6644-2211
Port 3 settings
ON
12345678
S1
Auto-negotiation and auto MDI/MDI-X disabled
ON
12345678
S1
Auto-negotiation and auto MDI/MDI-X enabled
ON
12345678
S1
10 Mbit/s speed selected
ON
12345678
S1
100 Mbit/s speed selected
ON
12345678
S2
Half duplex selected
ON
12345678
S2
Full duplex selected
Port 1 settings
ON
12345678
S1
Auto-negotiation and auto MDI/MDI-X disabled
ON
12345678
S1
Auto-negotiation and auto MDI/MDI-X enabled
ON
12345678
S1
10 Mbit/s speed selected
ON
12345678
S1
100 Mbit/s speed selected
ON
12345678
S1
Half duplex selected
ON
12345678
S1
Full duplex selected
Port 2 settings
ON
12345678
S1
Auto-negotiation and auto MDI/MDI-X disabled
ON
12345678
S1
Auto-negotiation and auto MDI/MDI-X enabled
ON
12345678
S1
10 Mbit/s speed selected
ON
12345678
S1
100 Mbit/s speed selected
ON
12345678
S1
Half duplex selected
ON
12345678
S1
Full duplex selected
S1
S2
Port 4 settings*
S2
Auto-negotiation and auto MDI/MDI-X disabled
S2
Auto-negotiation and auto MDI/MDI-X enabled
S2
10 Mbit/s speed selected
S2
100 Mbit/s speed selected
S2
Half duplex selected
S2
Full duplex selected
Port mirroring settings
S2
No monitoring selected
S2
Monitoring selected
Factory settings
ON
12345678
S1 S2
ON
12345
ON
12345
ON
12345
ON
12345
ON
12345
ON
12345
ON
12345
ON
12345
ON
12345
* Setting of port 4 is only possible when using
SDW-541. These settings are ignored when using SDW-532
Page 15
6.5 LED indicators
At power on the PWR flashes during initialising. Indicators (LED) Power (PWR)
Link (LINK) of every port Speed (SPD) and duplex (DPX) of TX ports
LED Status Indication of
PWR ON Internal power, initialising OK
Slow flash Initialisation progressing Fast flash Initialisation error
LINK OFF No Ethernet link
ON Good Ethernet link
Flash Ethernet data is transmitted or received, traffic indication SPD OFF 10 Mbit/s (TX only) ON 100 Mbit/s DPX OFF Half duplex (TX only) ON Full duplex
Page 16
T04-0330 • 6644-2210 04.12 Mälartryck AB, Eskilstuna, Sweden
Application example
Westermo Teleindustri AB • SE-640 40 Stora Sundby, Sweden
Phone +46 16 42 80 00 Fax +46 16 42 80 01
E-mail: info@westermo.se
Westermo Web site: www.westermo.com
Westermo Teleindustri AB have distributors in several countries, contact us for further information.
Westermo Data Communications Ltd Talisman Business Centre • Duncan Road Park Gate, Southampton • SO31 7GA Phone: +44(0)1489 580 585 • Fax.:+44(0)1489 580586 E-Mail: sales@westermo.co.uk
Westermo Data Communications GmbH Goethestraße 67, 68753 Waghäusel Tel.: +49(0)7254-95400-0 • Fax.:+49(0)7254-95400-9 E-Mail: info@westermo.de
Westermo Data Communications S.A.R.L. 9 Chemin de Chilly 91160 CHAMPLAN Tél : +33 1 69 10 21 00 • Fax : +33 1 69 10 21 01 E-mail : infos@westermo.fr
Subsidiaries
Loading...