Westermo SDW-541-SM-SC15, SDW-541-MM-SC2, SDW-541-MM-ST2, SDW-541-SM-LC15, SDW-532-MM-CS2 User Manual

...
Industrial Ethernet
5-port Switch
www.westermo.com
©
Westermo Teleindustri AB • 2004 • REV.A
User Guide
6644-2211
SERIES
2 6644-2211
Contents
1. Description .................................................................................................................................................................................................... 3
2. Safety ........................................................................................................................................................................................................................ 4
3. Approvals .......................................................................................................................................................................................................... 4
3.1 Declaration of Conformity ................................................................................................................................................... 5
4. Specification ........................................................................................................................................................................................ 6–7
5. Maintenance ................................................................................................................................................................................................ 8
6. Installation ...................................................................................................................................................................................................... 8
6.1 Mounting / Removal ....................................................................................................................................................................... 8
6.2 Connections ............................................................................................................................................................................................. 9
6.2.1 Power .............................................................................................................................................................................................. 10
6.2.2 TX ....................................................................................................................................................................................................... 10
6.2.3 FX SC Multi- or single mode (optional) ........................................................................................... 10
6.2.4 FX ST Multi mode (optional) ......................................................................................................................... 10
6.2.5 FX LC Single mode (optional) ...................................................................................................................... 10
6.3 DIP switch settings SDW-550 ........................................................................................................................... 11–12
6.4 DIP switch settings SDW-541 and SDW-532 ................................................................................ 13–14
6.5 LED indicators .................................................................................................................................................................................. 15
36644-2211
1. Description
The SDW-500 is a series of Industrial Ethernet 5-port switches. Several variations are available ranging from a version with five RJ-45 TX (copper) ports
to versions having two FX (fibre) and three TX ports. All TX ports support auto-negotiation, but DIP-switches also allow speed and duplex
configuration of any individual TX port. It is also possible to set up one port to monitor traffic to/from the switch.
The SDW-500 series has been designed to meet high industrial specifications, providing very high dependability in harsh environmental conditions.
Features:
… Flexible mix of TX (copper) and FX (fibre) interface … TX shields individually isolated … Wide DC power range 12–48 VDC … Wide temperature range … Redundant power … Automatic MDI/MDI-X crossover … LED indicators for Power, Speed, Duplex, Link and Traffic … Port monitoring … 35 mm DIN rail mounting … SC, ST and LC fibre interface … Multi (MM) and single mode (SM) fibre
Example of applications are:
… 5-port switch … Fibre to copper converter … Ethernet isolator, for STP network
4 6644-2211
3. Approvals
Conformity with the Directive 73/23/EEC Low Voltage Directive – LVD has been assessed by application of the standard EN 60 950.
Conformity with the Directive 89/336/EEC Electromagnetic Compatibility (EMC) has been assessed by application of standards EN 61000-6-2 (industrial immunity) and EN 61000-6-3 (residential emission) and EN61000-6-4 (Industrial emission).
2. Safety
General:
Before using this unit, read this manual completely and gather all information on the unit. Make sure that you understand it fully. Check that your application does not exceed the safe operating specifications for this unit.
Before installation, maintenance or modification work:
Prevent damage to internal electronics from electrostatic discharges (ESD) by discharging your body to a grounding point (e.g. use of wrist strap).
Prevent access to hazardous voltages by disconnecting the unit from AC/DC mains supply and all other electrical connections.
Installation:
This unit should only be installed by qualified personnel.
This unit should only be installed in a “restricted access area”, for example a lockable cabinet where access is restricted to service personnel only.
This unit is intended for permanent connection to the AC/DC mains supply.
The power supply wiring must be sufficiently fused, and if necessary it must be possible to disconnect manually from the AC/DC mains supply. Ensure compliance to national installation regulations.
Units with the rated voltage exceeding 42.4 V peak or 60 VDC, are defined as class I equipment with a protective earthing conductor terminal.
Units with the rated voltage up to 42.4 V peak or 60 VDC, are defined as class III equipment and shall be separated from hazardous voltage by double or reinforced isolation.
This unit uses convection cooling.To avoid obstructing the air flow around the unit, follow the spacing recommendations (see Installation section).
!
!
!
56644-2211
3.1 Declaration of Conformity
Westermo Teleindustri AB
Declaration of conformity
The manufacturer Westermo Teleindustri AB
SE-640 40 Stora Sundby, Sweden
Herewith declares that the product(s)
Type of product Model Art no Installation manual
DIN-rail SDW-550 LV 3644-0010 6644-2211 DIN-rail SDW-532-MM-SC2-SM-SC15 LV 3644-0019 6644-2211 DIN-rail SDW-541-MM-SC2 LV 3644-0020 6644-2211 DIN-rail SDW-541-MM-ST2 LV 3644-0021 6644-2211 DIN-rail SDW-541-SM-LC15 LV 3644-0022 6644-2211 DIN-rail SDW-541-SM-SC15 LV 3644-0024 6644-2211 DIN-rail SDW-532-2MM-SC2 LV 3644-0030 6644-2211 DIN-rail SDW-532-2MM-ST2 LV 3644-0031 6644-2211 DIN-rail SDW-532-2SM-LC15 LV 3644-0032 6644-2211 DIN-rail
SDW-532-2SM-SC15
LV 3644-0034 6644-2211
is in conformity with the following EC directive(s).
No Short name
89/336/EEG Electromagnetic Compatibility (EMC)
References of standards applied for this EC declaration of conformity.
No Title Issue
EN 61000-6-2 Immunity for industrial environments 2 (2001) EN 61000-6-3 Emission standard for residential, commercial and
1 (2001)
light-industrial environments (3644-0010)
EN 61000-6-4 Emission standard for industrial environments (3644-
1 (2001)
0020 and 3644-0030)
The last two digits of the year in which the CE marking was affixed: 04
Hans Levin Technical Manager 15th December2004
Postadress/Postal address Tel. Telefax Postgiro Bankgiro Corp. identity number Registered office
S-640 40 Stora Sundby 016-428000 016-428001 52 72 79-4 5671-5550 556361-2604 Eskilstuna
Sweden Int+46 16428000 Int+46 16428001
Org.nr/