Westermo RFR-12-FB User Manual

User Guide
6641-2222
RedFox
Westermo Teleindustri AB
©
Ethernet switch and router approved for railway usage
www.westermo.com
Software tools
Related software tools are available in the folder software tools under technical support on the Westermo website.
License Information
This device contains public available software which is under the GPL lincense. For more information see legal.pdf included with all firmware releases.
This product includes software developed by the OpenSSL Project for use in the OpenSSL Toolkit, http://www.openssl.org
Legal information
The contents of this document are provided “as is”. Except as required by applicable law, no warranties of any kind, either express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, are made in relation to the accuracy and reliability or contents of this document. Westermo reserves the right to revise this document or withdraw it at any time without prior notice.
Under no circumstances shall Westermo be responsible for any loss of data or income or any special, incidental, and consequential or indirect damages howsoever caused.
More information about Westermo can be found at the following Internet address:
http://www.westermo.com
2
6641-2222
Safety
!
!
Before installation:
Read this manual completely and gather all information on the unit. Make sure that you understand it fully. Check that your application does not exceed the safe operating specifications for this unit.
This unit should only be installed by qualified personnel.
This unit should be built-in to an apparatus cabinet, or similar, where access is restricted to service personnel only. The power supply wiring must be sufficiently fused, and if necessary it must be possible to disconnect manually from all power supply. Ensure compliance to national installation regulations. This unit relies on convection heating. Make sure that it is installed so that the ambient temperature is within the specified temperature range, e.g. by avoiding obstruction of the airflow around the unit. Also check chapter CEN/TS 45545-2 mounting notes.
Before mounting, using or removing this unit:
Prevent access to hazardous voltage by disconnecting the unit from all power supply.
WARNING
Do not open connected unit. Hazardous voltage may occur within this unit when connected to power supply.
Before powering-up, a protective earthing conductor must be connected to the protective earthing terminal and have a cross-sectional area of at least 1.5 mm². Note that this unit can be connected to two different power sources.
When this unit is operated at an ambient temperature above +60°C (+140°F), the External Surface of Equipment may exceed Touch Temperature Limit according to EN/IEC/UL 60950-1. To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cord.
6641-2222
3
Care recommendations
Follow the care recommendations below to maintain full operation of unit and to fulfill the warranty obligations:
Do not attempt to dissassemble the unit. There are not any user serviceable
parts inside.
Do not drop, knock or shake the unit. Rough handling above the specification
may cause damage to internal circuit boards.
Do not use harsh chemicals, cleaning solvents or strong detergents to clean the
unit.
Do not expose the unit to any kind of liquid (water, beverages, paint etc),
unless all connectors are connected or fitted with protective caps (delivered with the unit), tightened to the specified torque. Connected cables must have the appropriate ingress protection code.
Do not use or store the unit in dusty or dirty areas, unless all connectors and
the ventilation membrane are sufficiently protected.
Do not cover or bring mechanical force to the ventilation membrane on the
back of the unit.
If the unit is not working properly, contact the place of purchase, nearest Westermo distributor office or Westermo Tech support.
Maintenance
No maintenance is required, as long as the unit is used as intended within the specified conditions.
4
6641-2222
Agency approvals and standards compliance
Type Approval / Compliance
EMC EN 50121-3-2, Railway applications – EMC: Rolling stock – Apparatus
Railway applications, Approval/Compliance – EN 50155
Railway applications – Electronic equipment used on rolling stock
Safety EN 60950-1, IT equipment
6641-2222
5
Declaration of Conformity
Org.nr/
Westermo Teleindustri AB
Declaration of conformity
The manufacturer
Herewith declares that the product(s)
Type of product Model Art no EN 50155 Backbone Routing Switch RFR-12-FB 3641-1630
is in conformity with the following EC directive(s).
No Short name
2004/108/EC Electromagnetic Compatibility (EMC) 2006/95/EC Low voltage (LVD) 2011/65/EU Restriction of the use of certain hazardous substances in electrical and
References of standards applied for this EC declaration of conformity.
No Title Issue EN 50121-3-2 Railway applications - Electromagnetic compatibility -- Rolling
EN 60950-1 Information technology equipment - Safety -- General
The last two digits of the year in which the CE marking was affixed: 12
Westermo Teleindustri AB SE-640 40 Stora Sundby, Sweden
electronic equipment (RoHS)
stock - Apparatus
requirements
2006
2006 +A11:2009 +A1:2010 +A12:2011
Pierre Öberg Technical Manager 21st December 2012
Postadress/Postal address
S-640 40 Stora Sundby 016-428000 016-428001 52 72 79-4 5671-5550 556361-2604 Eskilstuna
Sweden Int+46 16428000 Int+46 16428001
Tel.
Telefax
Postgiro
Bankgiro Corp. identity number Registered office
6
6641-2222
Type tests and environmental conditions
Electromagnetic Compatibility Phenomena Standard Description Test Levels
ESD EN 61000-4-2 Enclosure contact
RF field AM modulated EN 61000-4-3 Enclosure RF immunity 20 V/m
Fast transients EN 61000-4-4 Signal port immunity ±2 kV
Surges EN 61000-4-5 Power port immunity ±2 kV (L-E)
EN 50155:2001 Power port immunity ±8.4 kV (L-E)
Conducted RF emision EN 61000-4-6 Signal port immunity 10 V/m
Power frequency magnetic field EN 61000-4-8 Enclosure immunity 300 A/m
Pulsed magnetic field EN 61000-4-9 Enclosure immunity 300 A/m Voltage interruption EN 50155 Residual voltage 0% 10 ms Supply overvoltage and
undervoltage Radiated emission EN 55011
Conducted emission EN 55011
Environmental
Temperature Operating –40 to +70°C* (–40 to +158°F)
Humidity Operating 5 to 95% relative humidity
Altitude Operating 2 000 m / 70 kPa Reliability prediction (MTBF) MIL-HDBK- 217F Operating 306 115 h
Shock IEC 60068-2-27 Operating 10 g, 30 ms Half sine ±3 shocks
Packaging
Dimension W x H x D 175 x 100 x 144 mm Weight 2295 g
Degree of protection IEC 529 Enclosure IP65** Cooling Convection Mounting Rear panel wall mounting
* Refer to “Safety” section ** Provided all connectors are connected with IP65 cabling or fitted with protective caps (delivered with the unit), tightened to the specified torque
EN 50155 Overvoltage 140%
Limits: EN 50121-3-2
Limits: EN 50121-3-2
IEC 60068-2-64 Operating Vertical 2.0 m/s² Transverse
IEEE 1478 Operating 20 g, 11 ms Saw tooth ±3 shocks
discharge immunity Enclosure air discharge
immunity
Power port immunity ±2 kV
Power port immunity 10 V/m
Residual voltage 60% Enclosure measurement 40 dBµV/m QP
Power port measurement 99 dBµV QP
Signal port measurement 99 dBµV QP
Storage & Transport –40 to +70°C (–40 to +158°F)
Storage & Transport 5 to 95% relative humidity
Non operating 11.4 m/s²
±6 kV
±8 kV
80 – 2700 MHz
±1 kV (L-L)
±8.4 kV (L-L)
0.15 – 80 MHz
0.15 – 80 MHz
0, 16.7, 50 Hz
100 ms & 1000 ms 100 ms
30 – 230 MHz 47 dBµV/m QP 230 – 1000 MHz
0.15 – 5 MHz 93 dBµV QP 5 – 30 MHz
0.15 – 5 MHz 93 dBµV QP 5 – 30 MHz
2.0 m/s² Longit. 2.0 m/s²
6641-2222
7
Description
Functional description
RFR-12-FB is switch developed for rail on board and industrial applications approved according to EN 50155. To meet the environmental requirements from rail and harsh industrial applications the switch has rugged M12 Ethernet connectors and full metal housing. The switch fulfill IP 65 degree of protection. Our unique FRNT (Fast Recovery of Network Topology) technology is the fastest protocol on the market to re-configure a network in the event of any failure of a link or hardware. Real-time properties are implemented in the RFR-12-FB in order to achieve determinism for real time critical applications. The switch also supports QoS (Quality of Service) with four priority queues and strict priority scheduling as well as HoL (Head of Line Blocking Prevention). All to assure that the data network is deter ministic. RFR-12-FB also has a by-pass relay that by-pass the unit in case of power loss to the switch.
8
6641-2222
Interface specifications
Power
Rated voltage 24 to 110 VDC
Operating voltage 16.8 to 143 VDC
(14.4 to 154 VDC for 100 ms)
Rated current 580 mA @ 24 VDC
140 mA @ 110 VDC
Inrush current 5 mA²s @ 24 VDC
22 mA²s @ 110 VDC
Startup current (Power source capability)
Polarity Reverse polarity protected
Redundant power input No
Isolation to All interfaces and chassis
Galvanic connection to None
Connection M12 A-coded male
Connector size 0.2 – 2.5 mm² (AWG 24 – 13)
Shielded cable Not required
Shielded cable Not required
Miscellaneous
600 mA @ 24 VDC 275 mA @ 110 VDC
2 1
M12 A-Coded Power Connector
3 4
Position Direction Description
1 U+ Positive supply voltage
2
3 0 V 0 V
4
Housing Shield Chassis of product (ground)
6641-2222
9
Ethernet TX (both switch, router and coupler ports)
Electrical specification IEEE std 802.3. 2000 Edition
Data rate 10 Mbit/s or 100 Mbit/s, manual or auto
Protocol
Duplex Full or half, manual or auto
Circuit type TNV-1
Transmission range 100 m
Isolation to All interfaces and chassis
Galvanic connection to None
Connection M12 D-coded
Shielded cable Ye s
Conductive housing Ye s
Miscellaneous
Number of ports 12
M12 D-coded, 10/100Base-TX
Position Direction Description
1 Out Transmit Data +
2 In Receive Data +
3 Out Transmit Data –
4 In Receive Data –
Housing Shield Chassis of product (ground)
10
6641-2222
Configuration backup device
Electrical specification USB
Memory size 16 Mbyte
Protocol USB v1.1
Connection M12 A-coded female
Isolation to All interfaces, but not to chassis
Shielded cable NA
Miscellaneous
USB / Configuration
Pin number Signal
No 1 DN
No 2 VBUS
No 3 NC
No 4 DP
No 5 GND
The agency approvals and standards compliance of the RFR-12 are valid with the WESTERMO USB configuration plug 3641-0190 attached. Only WESTERMO USB plugs are allowed for use together with this product.
6641-2222
11
Location of Interface ports, LED's
USB / Configuration
LED indicators
Earth connect
LED indicators
Ethernet
LED indicators
Power
12
6641-2222
LED indicators
LED Status Description
ON OFF Unit has no power.
GREEN All OK, no alarm condition.
RED Alarm condition, or until unit has started up.
BLINK Location indicator ("Here I am!"). Activated when connected to IPConfig Tool,
FRNT OFF FRNT disabled.
GREEN FRNT OK.
RED FRNT Error.
BLINK Unit configured as FRNT Focal Point.
RSTP OFF RSTP disabled.
GREEN RSTP enabled.
BLINK Unit selected as RSTP root switch.
USR 1 OFF (Configurable) VPN disabled.
GREEN (Configurable) Default: At least one VPN tunnel up and OK.
RED (Configurable) Default: All VPN tunnels down.
X1 to X12 OFF No Link.
GREEN Link established.
GREEN FLASH Data traffic indication.
YELLOW Port alarm and no link. Or if FRNT, RSTP or Link Aggregation mode,
(Alarm conditions are configurable, see ''WeOS Management Guide'').
or upon request from Web or CLI.
port is blocked.
6641-2222
13
By-Pass functionality
The by-pass functionality in RFR-12-FB secures connection in case of power failure in one of the switches. If a switch has power loss an internal relay in RFR-12-FB will by-pass the switch and bridge two Ethernet ports.
By-pass interfaces
In case of power failure X9 will be by-passed to X11 and X10 will be by-passed to X12.
Internally the switch will bypass
X9.1
X9.2 X11.1
X9.3 X11.4
X9.4 X11.3
X10.1 X12.2
Connected to
X10.2 X12.1
X10.3 X12.4
X10.4 X12.3
Note! Make sure that the maximum distance between switches will not exceed the standard (100 m) in case of by-passing one or more switches.
X11.2
X9
X11
X12
Switch 1 Switch 2 Switch 3
X11
X12
X10
X9
X10
14
6641-2222
Mounting
There are four 6 mm bore holes intended for mounting the unit. The unit can be mounted vertical or horizontal. Use four M5 screws with 12 mm washer on a flat and stable surface.
Connection of cables
Recommended tightening torque for the M12 connectors: 0.6 Nm. Note that unused connectors must be covered by a protective cap (delivered with the
unit), tightened to the specified torque, in order to fulfill the specified ingress protection code.
Removal
Disconnect all cables and unscrew the unit from the wall. Time For Replacement < 15 minutes
Cooling
This unit relies on convection cooling. Make sure that it is installed so that the ambient temperature is within the specified temperature range, e.g. by avoiding obstruction of the airflow around the unit.
6641-2222
15
Dimensions
142 ±1 11 ±1
164 ±1
175 ±1
22 ±1
28 ±0,5
M5
2,5 ±0,5
100 ±1
56 ±0,5
6,5
-0 0,5
(4x)
0
24,5
15,5
31
46,5
62
77,5
93
0
18,4
36,8
55,2
22,4
11,5 ±0,5
3 ±0,5
133,0 ±1,5
144,5 ±1,5
Material / Remark
Designation / Dimension
Description
Quantity
Pos No
1:1.5
Scale
Status
Designer
Drawing No.
PaPu
Sheet
1(1)
Denomination
RFR-series
Approved
Date
130225
ToDu
ToDu
130225
Created
01
PaPu
Approved
Date
Rev
Designer
Description
Measurements are stated in millimeters.
16
6641-2222
Getting Started
This product runs Westermo Operating System (WeOS) which provides several management tools that can be used for configuration of the unit.
• IPConfig tool
This is a custom Westermo tool used for discovery of attached Westermo units.
• Web
Configuration of the unit using the web browser.
• CLI Configuration of the unit via the Command Line Interface.
If the computer is located in the same subnet as the switch you can easily use a web browser to configure the unit. Within the web you can configure most of the available functions.
For advanced network settings and more diagnostic information, please use the CLI. Detailed documentation is available in the chapter The Command Line Management Tool in the WeOS management guide.
Factory default IP address: 192.168.2.200 Netmask: 255.255.255.0 Gateway: Disabled
Note! If you are not sure about the subnet – consult your network administrator.
Configuration
Configure the unit via Webbrowser
The unit can easily be configured via a Web browser. Open the link http://192.168.2.200 in your web browser, and you will be prompted with a Login screen, where the default settings for Username and Password are:
Username: admin Password: westermo
Once you have logged in, you can use the extensive integrated help function describing all configuration options. Two common task when configuring a new switch is to assign appropriate IP settings, and to change the password of the admin account. The password can be up to 64 characters long, and should consist of printable ASCII characters (ASCII 33-126); 'Space' is not a valid password character.
Note! Version of IP Config tool must be 10.4 or higher.
6641-2222
17
Referring documents
Type Description Document number
Management Guide Westermo OS management guide
6101-3201
Factory default on RFR-12-FB
It is possible to set the unit to factory default settings by using Ethernet M-12 cables.
1. Power off the switch and disconnect all Ethernet cables.
2. Connect the first Ethernet cable between Ethernet port X1 and Ethernet port X6. Then connect the second Ethernet cable between Ethernet port X2 and Ethernet port X5. The ports need to be connected directly by an Ethernet cable, i.e., not via a hub or switch. Use a straight cable – not a cross-over cable – when connecting the ports.
3. Power on the unit.
4. Wait for the unit to start up. Control that the ON LED is flashing red. The ON LED flashing indicates that the unit is now ready to be reset to factory default. You now have the choice to go ahead with the factory reset, or to skip factory reset and boot as normal.
• Go ahead with factory reset:
Acknowledge that you wish to conduct the factory reset by unplugging one of the Ethernet cables. The ON LED will stop flashing. This initiates the factory reset process*, and the unit will restart with factory default settings. When the switch has booted up, the ON LED will show a green light, and is now ready to use.
• Skip the factory reset:
To skip the factory reset process, just wait for approximately 30 seconds (after the ON LED starts flashing RED) without unplugging the Ethernet cable. The switch will conduct a normal boot with the existing settings.
* Note Do not power off the unit while the factory reset process is in progress.
18
6641-2222
6641-2222
19
Westermo • SE-640 40 Stora Sundby, Sweden
Tel +46 16 42 80 00 Fax +46 16 42 80 01
Sales Units
Westermo Data Communications
E-mail: info@westermo.com
www.westermo.com
China sales.cn@westermo.com www.cn.westermo.com
France infos@westermo.fr www.westermo.fr
Germany info@westermo.de www.westermo.de
For complete contact information, please visit our website at www.westermo.com/contact or scan the QR code
REV. E 6641-2222 2015-05 Westermo Teleindustri AB, Sweden – A Beijer Electronics Group Company
North America
info@westermo.us www.westermo.us
Singapore sales@westermo.com.sg www.westermo.com
Sweden
info.sverige@westermo.se www.westermo.se
United Kingdom sales@westermo.co.uk www.westermo.co.uk
Other Offices
Loading...