Related software tools are available in the folder software tools under
technical support on the Westermo website.
License Information
This device contains public available software which is under the GPL license. For
more information see legal.pdf included with all firmware releases.
This product includes software developed by the OpenSSL Project for use in the
OpenSSL Toolkit. http://www.openssl.org
Legal information
The contents of this document are provided “as is”. Except as required by applicable
law, no warranties of any kind, either express or implied, including, but not limited to,
the implied warranties of merchantability and fitness for a particular purpose, are made
in relation to the accuracy and reliability or contents of this document. Westermo
reserves the right to revise this document or withdraw it at any time without prior
notice.
Under no circumstances shall Westermo be responsible for any loss of data or income
or any special, incidental, and consequential or indirect damages howsoever caused.
More information about Westermo can be found at the following Internet address:
http://www.westermo.com
2
6641-22810
Page 3
Safety
!
!
!
Before installation:
Read this manual completely and gather all information on the unit. Make sure
that you understand it fully. Check that your application does not exceed the safe
operating specifications for this unit.
This unit should only be installed by qualified personnel.
This unit should be built-in to an apparatus cabinet, or similar, where access is
restricted to service personnel only.
The power supply wiring must be sufficiently fused, and if necessary it must be
possible to disconnect manually from the power supply. Ensure compliance to
national installation regulations.
This unit uses convection cooling. To avoid obstructing the airflow around the unit,
follow the spacing recommendations (see Cooling section).
Before powering-up, a protective earthing conductor must be connected to the
protective earthing terminal and have a cross-sectional area of at least 1.5 mm².
Before mounting, using or removing this unit:
Prevent access to hazardous voltage by disconnecting the unit from power supply.
Warning! Do not open connected unit. Hazardous voltage may occur within this
unit when connected to power supply.
Class 1 Laser Product
Do not look directly into fibre optical fibre port or any connected fibre although
this unit is designed to meet the Class 1 Laser regulations.
Care recommendations
Follow the care recommendations below to maintain full operation of unit and to fulfil
the warranty obligations.
This unit must not be operating with removed covers or lids.
Do not attempt to disassemble the unit. There are no user serviceable parts inside.
Do not drop, knock or shake the unit, rough handling above the specification may cause
damage to internal circuit boards.
Do not use harsh chemicals, cleaning solvents or strong detergents to clean the unit.
Do not paint the unit. Paint can clog the unit and prevent proper operation.
Do not expose the unit to any kind of liquids (rain, beverages, etc). The unit is not
waterproof. Keep the unit within the specified humidity levels.
Do not use or store the unit in dusty, dirty areas, connectors as well as other mechanical
part may be damaged.
If the unit is not working properly, contact the place of purchase, nearest Westermo
distributor office or Westermo Tech support.
Fibre connectors are supplied with plugs to avoid contamination inside the optical port.
As soon as no optical fibre is mounted on the connector, e.g. for storage, service or
transportation, the plug should be applied.
Warning:
To reduce the risk of fire, use on No. 26 AWG or larger telecommunication line cord.
6641-22810
3
Page 4
Note. Fibre Optic Handling
Fibre optic equipment needs special treatment. It is very sensitive to dust and dirt. If the
fibre will be disconnected from the unit the protective hood on the transmitter/receiver
must be connected. The protective hood must be kept on during transportation. The
fibre optic cable must also be handle the same way.
If these recommendations are not followed the warranty might be jeopardized.
Cleaning of the optical connectors
In the event of contamination, the optical connectors should only be cleaned by the use
of recommended cleaning fluids and correct cleaning equipment.
Recommended cleaning fluids:
• Methyl-, ethyl-, isopropyl- or isobutyl-alcohol
• Hexane
• Naphtha
Maintenance
No maintenance is required, as long as the unit is used as intended within the specified
conditions.
Electromagnetic compatibility – Emission and
immunity of the signalling and telecommunications
apparatus
EN 55022, Information technology equipment –
Radio disturbance characteristics – Limits and
methods of measurement
EN 55024, Information technology equipment –
Immunity characteristics Limits and methods of
measurement
EN 61000-6-1, Electromagnetic compatibility –
Immunity for residential environments
EN 61000-6-2, Electromagnetic compatibility –
Immunity for industrial environments
EN 61000-6-4, Electromagnetic compatibility –
Emission for industrial environments
FCC Part 15 Class A
Marine DNV Standard for Certification no. 2.4
FCC Part 15.105
Notice:
EN 55022 Notice:
This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
This is a class A product. In a domestic environment this product may cause radio
interference in which case the user may be required to take adequate measures.
DNV Standard for Certification no. 2.4
TypeTemperature Humidity VibrationEMCEnclosure
RFIR-2xx-F4G-T7G-ACCBAAA/IP40
RFIR-2xx-F4G-T7G-DCDBABA/IP40
6641-22810
5
Page 6
Safety control drawing
DC
Direction/
Position
description
1In/out / BI_DA+
2In/out / BI_DA–
3In/out / BI_DB+
4In/out / BI_DC+
5
In/out / BI_DC–
6In/out / BI_DB–
7In/out / BI_DD+
8In/out / BI_DD–
Shield Functional earth
Galvanically isolated via signal transformers and
capacitively isolated to GND/Functional earth
through a 2kV 1000pF capacitor.
See user manual for proven transient protection.
Position Direction* / description Input/output values
1In/out / TD+
2In/out / TD–
3In/out / RD+
4Not connected
5
Not connected
6In/out / RD–
7Not connected
Per port:
U = ± 1 V (4V/us)
I = ± 20 mA
Data rate:
10/100 Mbit/s
8Not connected
Shield Functional earth
Galvanically isolated via signal transformers and capacitively
isolated to functional earth through a 2kV 1000pF
capacitor.
See user manual for proven transient protection.
Position Direction* / description Input/output values
RxIn / Receive port
TxOut / Transmit port
Max 5 dBm
Position Direction* / description Input/output values
1In/out / BI_DA+
2In/out / BI_DA–
3In/out / BI_DB+
4In/out / BI_DC+
5In/out / BI_DC–
6In/out / BI_DB–
7In/out / BI_DD+
Per port:
U = ± 1 V (4V/us)
I = ± 20 mA
Data rate:
100/1000 Mbit/s
8In/out / BI_DD–
Shield Functional earth
Galvanically isolated via signal transformers and capacitively
isolated to functional earth through a 2kV 1000pF
capacitor. See user manual for proven transient protection.
* Direction relative this unit!
6641-22810
7
Page 8
Declaration of Conformity
Org.nr/
th
Westermo Teleindustri AB
Declaration of conformity
The manufacturer
Herewith declares that the product(s)
Type of product Article number Models
Industrial Ethernet Switch
for 19 inch Rack mounting
is in conformity with the following EC directive(s).
No Short name
2004/108/EC Electromagnetic Compatibility (EMC)
2011/65/EU Restriction of the use of certain hazardous substances in electrical and electronic
References of standards applied for this EC declaration of conformity.
No Title Issue
EN 50121-4 Railway applications – Electromagnetic compatibility – Emission
EN 55022 Information technology equipment – Radio disturbance
EN 55024 Information technology equipment – Immunity characteristics
EN 61000-6-1 Electromagnetic compatibility – Immunity for residential
EN 61000-6-2 Electromagnetic compatibility – Immunity for industrial
EN 61000-6-4 Electromagnetic compatibility – Emission for industrial
EN 50581 Technical documentation for the assessment of electrical and
The last two digits of the year in which the CE marking was affixed: 14
Westermo Teleindustri AB
SE-640 40 Stora Sundby, Sweden
3641-4025
3641-4005
3641-4035
3641-4015
equipment (RoHS)
and immunity of the signalling and telecommunications
apparatus
characteristics – Limits and methods of measurement
Limits and methods of measurement
environments
environments
environments
electronic products with respect to the restriction of hazardous
substances
S-640 40 Stora Sundby 016-428000 016-428001 52 72 79-4 5671-5550 556361-2604 Es kilstuna
Sweden Int+46 16428000 Int+46 16428001
Tel.
Telefax
Postgiro
Bankgiro Corp. identity number Registered office
8
6641-22810
Page 9
Type tests and environmental conditions
PhenomenaTestDescriptionTest levels
ESDEN 61000-4-2Enclosure contact ± 6 kV
RF field AM modulated IEC 61000-4-3Enclosure20 V/m 80% AM (1 kHz), 80 – 2700 MHz
Fast transientEN 61000-4-4Signal ports± 2 kV
SurgeEN 61000-4-5Signal ports± 2 kV line to earth, ± 1 kV line to line
RF conductedEN 61000-4-6Signal ports10 V 80% AM (1 kHz), 0.15 – 80 MHz
Power frequency
magnetic field
Pulse magnetic fieldEN 61000-4-9Enclosure300 A/m
Radiated emission CISPR 16-2-3EnclosureClass A
Conducted emissionEN 55022AC and DC power
Dielectric strengthEN 60950Signal port to other
TemperatureEN 60068-2-1
HumidityEN 60068-2-27Operating5 to 95% relative humidity
AltitudeOperating2 000 m / 70 kPa
Service lifeOperating10 years
VibrationIEC 60068-2-6Operating7.5 mm, 5 – 8 Hz
ShockIEC 60068-2-27Operating15 g, 11 ms
EnclosureUL 94Aluminium / ZinkFlammability class V-0 (all models)
EN 61000-4-8Enclosure300 A/m 0, 16.7, 50, 60 Hz
ANSI C63.4
(FCC part 15)
FCC part 15AC and DC power
EN 60068-2-2
Enclosure air± 8 kV
Power ports± 2 kV
Power ports± 2 kV line to earth, ± 2 kV line to line
Power ports10 V 80% AM (1 kHz), 0.15 – 80 MHz
EnclosureClass B, 30 – 6500 MHz
ports
Telecommunication
ports Class B
ports
isolated ports
Power port to other
isolated ports
Operating-40 to +70ºC (DC models)
Storage & Transport-40 to +85ºC (all models)
Maximum surface
temperature
Storage & Transport5 to 95% relative humidity
(AC models)
± 2 kV line to earth, ± 1 kV line to line
(DC models)
Class B
Class B
1.5 kVrms 50 Hz 1 min
1.5 kVrms 50 Hz 1 min
-40 to +55ºC (AC models)
135 °C (temperature class T4)
2 g, 8 – 500 Hz
(19" rack mounting according to IEC 60297,
DIN 41494)
(19" rack mounting according to IEC 60297,
DIN 41494)
6641-22810
9
Page 10
Description
The RFIR (RedFox Industrial Rack) is a high performance layer 3 industrial Ethernet
switch designed for high network traffic applications. Various port configurations are
available that can be further customized with SFP transceivers. RFIR is powered by the
Westermo WeOS network operating system.
RFIR is designed for 19” cabinet according to ETSI standard making it suitable for use
in control room networks as well as for cabi¬nets installed along railway trackside or
maritime installations. RFIR is designed to run efficiently from an AC or DC power supply,
the unit is also equipped with configurable I/O fault contact that make it ideal for easy
installation and monitoring in industrial applications.
RedFox Industrial Rack models
Westermo
article number
3641-4005RFIR-219-F4G-T7G-DC
3641-4015RFIR-219-F4G-T7G-AC
3641-4025RFIR-227-F4G-T7G-DC
3641-4035RFIR-227-F4G-T7G-AC
DenominationDescription
8 x 10/100 Mbit/s, Ethernet TX, RJ-45
7 x 10/100/1000 Mbit/s, Gigabit Ethernet TX, RJ-45
4 x 100/1000 Mbit/s, pluggable connections
transceivers supported, Ethernet FX or TX SFP
DC power supply
8 x 10/100 Mbit/s, Ethernet TX, RJ-45
7 x 10/100/1000 Mbit/s, Gigabit Ethernet TX, RJ-45
4 x 100/1000 Mbit/s, pluggable connections
transceivers supported, Ethernet FX or TX SFP
AC power supply
16 x 10/100 Mbit/s, Ethernet TX, RJ-45
7 x 10/100/1000 Mbit/s, Gigabit Ethernet TX, RJ-45
4 x 100/1000 Mbit/s, pluggable connections
transceivers supported, Ethernet FX or TX SFP
DC power supply
16 x 10/100 Mbit/s, Ethernet TX, RJ-45
7 x 10/100/1000 Mbit/s, Gigabit Ethernet TX, RJ-45
4 x 100/1000 Mbit/s, pluggable connections
transceivers supported, Ethernet FX or TX SFP
AC power supply
10
6641-22810
Page 11
480
43
469
462
18
REVISIONS
Rev
Description
Designer
Approved
Date
Housing
REVISIONS
Rev
Description
Designer
Approved
Date
Description
The RedFox Industrial Rack (RFIR) is designed for installation in 19” rack solutions
according to ETSI standard with a shallow depth of 240 mm. RFIR can also be wall
mounted as an installation option.
Port number RFIR-219-F4G-T7G DC or AC
Port number RFIR-227-F4G-T7G DC or AC
480
43
462
469
411
235
466
Specification
Dimension W x H x D466 x 258 x 43 mm
18,35 x 10,16 x 1,66"
Weight3.8 kg
Degree of protectionIP40 according to EN 60529
CoolingConvection
Mounting19" rack or wall-mounted
6641-22810
240
11
Page 12
Interface specifications
I/OUSB
Console
port
10/100/1000 Mbit/s
SFP slot, 100/1000 Mbit/s FX or
10/10/1000 Mbit/s TX ports
10/100 Mbit/s TX ports
TX ports
Power interface specifications
DC power
4-position Product marking DirectionDescription
AC power
1
1
2
3
4
3
2
4
No. 1+DC1InputSupply voltage input DC1
No. 2+DC2InputSupply voltage input DC2
No. 3-COMInputCommon
No. 4-COMInputCommon
4-position Product marking DirectionDescription
No. 1PInputPower
No. 2NInputNeutral
No. 3NCInputNo connection
No. 4InputFuntional earth
Power
Protective earth
12
6641-22810
Page 13
Power
Rated voltage AC models100 to 240 VAC, 50-60 Hz
DC models20 to 48 VDC
Operating voltage AC models90 to 264 VAC, 47-63 Hz
DC models16 to 60 VDC
Maximum nominal current
consumption
RFIR-219-F4G-T7G-DC 1120 mA @ 24 VDC
450 mA @ 48 VDC
RFIR-227-F4G-T7G-DC 1250 mA @ 24 VDC
550 mA @ 48 VDC
RFIR-219-F4G-T7G-AC360 mA @ 100 VAC 60 Hz
200 mA @ 240 VAC 50 Hz
RFIR-227-F4G-T7G-AC350 mA @ 110 VAC 60Hz
210 mA @ 230 VAC 50Hz
Fuse ratingAll models4A(T)**
Inrush current DC models25 mA2 @ 24 VDC
165 mA2 @ 48 VDC
AC models75 mA2 @ 110 VAC
340 mA2 @ 230 VAC
Startup current* All models2x nominal current
Rated frequency AC models50/60 Hz
DC modelsDC
Polarity AC modelsNot applicable
DC modelsReverse polarity protected
Redundant power input AC modelsNo
DC modelsYe s
Isolation to All other
ConnectionDetachable screw terminal
Connector sizeAll models0.2 – 2.5 mm2
(AWG 24 – 12)
Shielded cableNot required
* External supply current capability for proper start-up
** Denote time-delay fuse
6641-22810
13
Page 14
Console
Connection to console port
The console port can be used to connect to the CLI (Command Line
Interface). The console connector is a micro USB cable that connects to
a FTDI FT232R USB to serial converter internally. For drivers please see
www.ftdichip.com and download the appropriate VCP driver.
Console
Electrical specificationUSB 2.0 device interface
Data rateHigh speed 480mbit/s
Circuit typeSE LV
Maximum supply current100 mA
Isolation toAll other except USB
Galvanic connection toUSB
ConnectionUSB Micro-B connector in device mode
USB
USB
Electrical specificationUSB 2.0 host interface
Data rateHigh speed 480mbit/s
Circuit typeSELV
Maximum supply current500 mA
Isolation toAll other except Console
ConnectionUSB receptacle connector type A
Conductive housingYes
14
6641-22810
Page 15
Network ports
Slot 1Slot 2*Slot 3*Slot 4*
RFIR-219-F4G-T7G DC and AC
Slot 1
110/100/1000 Mbit/s, TX port
210/100/1000 Mbit/s, TX port
310/100/1000 Mbit/s, TX port
Slot 2
4SFP slot
510/100/1000 Mbit/s, TX port
6SFP slot
710/100/1000 Mbit/s, TX port
8SFP slot
910/100/1000 Mbit/s, TX port
10SFP slot
1110/100/1000 Mbit/s, TX port
Slot 3
1210/100 Mbit/s, TX port
1310/100 Mbit/s, TX port
1410/100 Mbit/s, TX port
1510/100 Mbit/s, TX port
1610/100 Mbit/s, TX port
1710/100 Mbit/s, TX port
1810/100 Mbit/s, TX port
1910/100 Mbit/s, TX port
* Network ports at slot 2 and slot 3 differ
between the different RFIR models. Slot 4
is only available in model RFIR-227-F4GT7G DC and AC.
Data rate10 Mbit/s, 100 Mbit/s, 1000 Mbit/s, manual or auto
DuplexFull or half, manual or auto
Circuit typeTNV-1
Transmission rangeUp to 150 m with CAT5e cable or better
Isolation toAll other
ConnectionRJ-45 auto MDI/MDI-X
Shielded cableNot required, except when installed in Railway applications as
Conductive housingYes
* NOTE! Railway installation close to the rails.
To minimise the risk of interference, a shielded cable is recommended when the cable is located
inside 3 m boundary to the rails and connected to this port.
The cable shield should be properly connected (360°) to an earthing point within 1 m from this
port. This earthing point should have a low impedance connection to the conductive enclosure of
the apparatus cabinet, or similar, where the unit is built-in. This conductive enclosure should be
connected to the earthing system of an installation and may be directly connected to the functional
earth. Refer also to "Safety" section.
signalling and telecommunications apparatus and located close
to rails*
PositionDirection*Description
1In/OutBI_DA+
2In/OutBI_DA–
3In/OutBI_DB+
4In/OutBI_DC+
5In/OutBI_DC-
6In/OutBI_DB-
7In/OutBI_DD+
8In/OutBI_DD-
ShieldIn/OutConnected to
Functional earth
* Direction relative this unit.
16
6641-22810
Page 17
1
5
2
6
3
7
4
8
SFP slot
Each SFP slot can hold one SFP transceiver for copper or fibre cable. Fibre transcievers distances
range from 550 m (0.34 mi) to 120 km (74.6 mi). For supported transceivers, see SFP data sheet.
ConnectionSFP slot holding fibre transceiver or copper transceiver
* 100 Mbit/s or 1000 Mbit/s transceiver supported.
6641-22810
17
Page 18
I/O connection
Product markingDirectionDescription
DI-
DI+
DO-
DO+
The Status output is a potential free, opto-isolated normally closed solid-state relay. This can be configured to
monitor various alarm events within the RFIR unit, see WeOS Management Guide. An external load in series
with an external voltage source is required for proper functionality. For voltage/current ratings, see Interface
specification section.
Digital in –InputDigital in –
Digital in +InputDigital in +
Status –OutputAlarm relay (status) contact
Status +OutputAlarm relay (status) contact
The Digital in is an opto-isolated
digital input which can be used
to monitor external events.
For voltage/current ratings, see
Interface Specification section:
IO / Relay output
Connect resistance30 W
Isolation to All other
ConnectionDetachable screw terminal
Connector size 0.2 – 2.5 mm2 (AWG 24 – 12)
Maximum voltage/current60 VDC / 80 mA
IO / Digital input
Voltage levelsVih > 8V Vil < 5V
Iin = 2.9mA @60V
Isolation to All other
ConnectionDetachable screw terminal
Connector size 0.2 – 2.5 mm2 (AWG 24 – 12)
Maximum voltage60 VDC
External
Load
1
Status
2
3
4
V
V
+
Digital In
–
18
6641-22810
Page 19
LED indicators Power/CPU
LEDStatusDescription
ONOFFUnit has no power.
GREENAll OK, no alarm condition.
REDAlarm condition, or until unit has
BLINKLocation indicator ("Here I am!").
DC1 OFFUnit has no power.
GREENPower OK on DC1.
RED+DC1 input voltage is below operating
DC2 OFFUnit has no power.
GREENPower OK on DC2.
RED+DC2 input voltage is below operating
AC1OFFUnit has no power
GREENPower OK on AC1
FRNT OFFFRNT disabled.
GREENFRNT OK.
REDFRNT Error.
BLINKUnit configured as FRNT Focal Point.
RSTP OFFRSTP disabled.
GREENRSTP enabled.
BLINKUnit elected as RSTP/STP root switch.
USR1Configurable, see WeOS Management Guide
TX/FX portsOFFNo link.
GREENLink established.
GREEN
FLASH
YELLOW Port alarm and no link. Or if FRNT or
started up. (Alarm conditions are
configurable, see ''WeOS Management
Guide'').
Activated when connected to IPConfig
Tool, or upon request from Web or
CLI.
See SFP Transceivers data sheet for supported SFP transceivers.
Note: The unit supports Westermo labelled transceivers only.
See Transceiver User Guide 6100-0000 for transceiver handling
instructions.
Deviations
With copper transceiver 1100-0148 the specified operating
temperature on the RFI and RFIR series is 0 to 50ºC.
FRNT reconfiguration times can not be guaranteed with
copper transceivers.
20
6641-22810
Page 21
Mounting
This unit can either be rackmounted or wallmounted, see figures below.
Rackmounting
_
<
The unit can be mounted in all directions
+85°C (+185°F)
inside a 19" apparatus cabinet. Use M6x25 or
1/4"x1" screws.
Wallmounting
The unit can also be wallmounted in all
directions. Use maximum Ø6,4 mm or
_
<
+85°C (+185°F)
1/4"screws.
Cooling
For mounting in 19" apparatus cabinet without forced ventilation, a minimal spacing of
1U according to IEC 60297 or 45 mm (1.75") above/below is recommended. With forced
ventilation, no minimal spacing is required as long as the temperature of the rear cooling
plates does not exceed +85ºC (+185ºF).
For wallmounting in an area without forced ventilation, a minimum spacing of 45 mm
(1.75") above/below and 10 mm (0.4") left/right is recommended. For areas with forced
ventilation, no minimal spacing is required as long as the temperature of the rear cooling
plates does not exceed +85ºC (+185ºF).
Earth connection
For correct function, the ground connection on the unit needs to be properly connected
to a solid ground. See the figure below.
Protective earth
6641-22810
21
Page 22
Getting Started
This product runs Westermo Operating System (WeOS) which provides several
management tools that can be used for configuration of the unit.
• WeConfig
WeConfig is a Network configuration management tool (NCM) made for
commissioning and maintenance of components in a network.
• Web
Configuration of the unit using the web browser.
• CLI
Configuration of the unit via the Command Line Interface.
If the computer is located in the same subnet as the switch you can easily use a web
browser to configure the unit. Within the web you can configure most of the available
functions.
For advanced network settings and more diagnostic information, please use the CLI.
Detailed documentation is available in the chapter ”The Command Line Management
Tool” in the WeOS management guide.
Factory default IP address:192.168.2.200 (and DHCP client)
Netmask:255.255.255.0
Gateway:Disabled
Note! If you are not sure about the subnet – consult your network administrator.
Configuration
Configure the unit via Web browser
The unit can easily be configured via a Web browser.
Open the link http://192.168.2.200 in your web browser, and you will be prompted with a
Login screen, where the default settings for Username and Password are:
Username: admin
Password: westermo
Once you have logged in, you can use the extensive integrated help function describing
all configuration options. Two common task when configuring a new switch is to assign
appropriate IP settings, and to change the password of the admin account. The password
can be up to 64 characters long, and should consist of printable ASCII characters (ASCII
33-126); 'Space' is not a valid password character.
22
6641-22810
Page 23
Referring documents
All needed documentation can be downloaded from the product webpage. Related
software tools are available in the folder software tools under technical support on the
Westermo website.
TypeDescriptionDocument number
Management GuideWestermo OS management guide
6101-3201
Cable factory reset on RedFox Industrial Rack
It is possible to set the unit to factory default settings by using a standard (straight)
Ethernet RJ-45 cable.
1. Power off the switch and disconnect all Ethernet cables (including copper and
fibre).
2. Connect an Ethernet cable between Ethernet port 1 and Ethernet port 2. The
ports need to be connected directly by an Ethernet cable, i.e., not via a hub or
switch. Use a straight cable - not a cross-over cables - when connecting the ports.
3. Power on the unit.
4. Wait for the unit to start up. Control that the ON LED is flashing red. The ON
LED flashing indicates that the unit is now ready to be reset to factory default. You
now have the choice to go ahead with the factory reset, or to skip factory reset
and boot as normal.
• Go ahead with factory reset: Acknowledge that you wish to conduct the
factory reset by unplugging the Ethernet cable. The ON LED will stop
flashing. This initiates the factory reset process, and the unit will restart with
factory default settings. When the switch has booted up, the ON LED will
show a green light, and is now ready to use.
• Note! Do not power off the unit while the factory reset process is in
progress. Skip the factory reset: To skip the factory reset process, just wait
for approximately 30 seconds (after the ON LED starts flashing RED)
without unplugging the Ethernet cable. The switch will conduct a normal
boot with the existing settings.
6641-22810
23
Page 24
Westermo • SE-640 40 Stora Sundby, Sweden
Tel +46 16 42 80 00 Fax +46 16 42 80 01
Sales Units
Westermo Data Communications
E-mail: info@westermo.com
www.westermo.com
China
sales.cn@westermo.com
www.cn.westermo.com
France
infos@westermo.fr
www.westermo.fr
Germany
info@westermo.de
www.westermo.de
For complete contact information, please visit our website at www.westermo.com/contact or scan the QR code
REV. D 6641-22810 2015-06 Westermo Teleindustri AB, Sweden – A Beijer Electronics Group Company
North America
info@westermo.com
www.westermo.com
Singapore
sales@westermo.com.sg
www.westermo.com
Sweden
info.sverige@westermo.se
www.westermo.se
United Kingdom
sales@westermo.co.uk
www.westermo.co.uk
Other Offices
Loading...
+ hidden pages