Westermo RFIR-xxx User Manual

Page 1
User Guide
6641-22810
RedFox
Westermo Teleindustri AB
©
WeOS
Industrial Rack
Industrial Routing Switch
www.westermo.com
Page 2
Software tools
Related software tools are available in the folder software tools under technical support on the Westermo website.
License Information
This device contains public available software which is under the GPL license. For more information see legal.pdf included with all firmware releases.
This product includes software developed by the OpenSSL Project for use in the OpenSSL Toolkit. http://www.openssl.org
Legal information
The contents of this document are provided “as is”. Except as required by applicable law, no warranties of any kind, either express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, are made in relation to the accuracy and reliability or contents of this document. Westermo reserves the right to revise this document or withdraw it at any time without prior notice.
Under no circumstances shall Westermo be responsible for any loss of data or income or any special, incidental, and consequential or indirect damages howsoever caused. More information about Westermo can be found at the following Internet address:
http://www.westermo.com
2
6641-22810
Page 3
Safety
!
! !
Before installation:
Read this manual completely and gather all information on the unit. Make sure that you understand it fully. Check that your application does not exceed the safe operating specifications for this unit. This unit should only be installed by qualified personnel. This unit should be built-in to an apparatus cabinet, or similar, where access is restricted to service personnel only. The power supply wiring must be sufficiently fused, and if necessary it must be possible to disconnect manually from the power supply. Ensure compliance to national installation regulations. This unit uses convection cooling. To avoid obstructing the airflow around the unit, follow the spacing recommendations (see Cooling section).
Before powering-up, a protective earthing conductor must be connected to the protective earthing terminal and have a cross-sectional area of at least 1.5 mm².
Before mounting, using or removing this unit:
Prevent access to hazardous voltage by disconnecting the unit from power supply. Warning! Do not open connected unit. Hazardous voltage may occur within this unit when connected to power supply.
Class 1 Laser Product
Do not look directly into fibre optical fibre port or any connected fibre although this unit is designed to meet the Class 1 Laser regulations.
Care recommendations
Follow the care recommendations below to maintain full operation of unit and to fulfil the warranty obligations. This unit must not be operating with removed covers or lids. Do not attempt to disassemble the unit. There are no user serviceable parts inside. Do not drop, knock or shake the unit, rough handling above the specification may cause damage to internal circuit boards. Do not use harsh chemicals, cleaning solvents or strong detergents to clean the unit. Do not paint the unit. Paint can clog the unit and prevent proper operation. Do not expose the unit to any kind of liquids (rain, beverages, etc). The unit is not waterproof. Keep the unit within the specified humidity levels. Do not use or store the unit in dusty, dirty areas, connectors as well as other mechanical part may be damaged. If the unit is not working properly, contact the place of purchase, nearest Westermo distributor office or Westermo Tech support. Fibre connectors are supplied with plugs to avoid contamination inside the optical port. As soon as no optical fibre is mounted on the connector, e.g. for storage, service or transportation, the plug should be applied.
Warning:
To reduce the risk of fire, use on No. 26 AWG or larger telecommunication line cord.
6641-22810
3
Page 4
Note. Fibre Optic Handling
Fibre optic equipment needs special treatment. It is very sensitive to dust and dirt. If the fibre will be disconnected from the unit the protective hood on the transmitter/receiver must be connected. The protective hood must be kept on during transportation. The fibre optic cable must also be handle the same way.
If these recommendations are not followed the warranty might be jeopardized.
Cleaning of the optical connectors
In the event of contamination, the optical connectors should only be cleaned by the use of recommended cleaning fluids and correct cleaning equipment.
Recommended cleaning fluids:
• Methyl-, ethyl-, isopropyl- or isobutyl-alcohol
• Hexane
• Naphtha
Maintenance
No maintenance is required, as long as the unit is used as intended within the specified conditions.
4
6641-22810
Page 5
Agency approvals and standards compliance
Art.no Denomination Type Approval/compliance
3641-4005 3641-4015 3641-4025 3641-4035
RFIR-219-F4G-T7G-DC RFIR-219-F4G-T7G-AC RFIR-227-F4G-T7G-DC RFIR-227-F4G-T7G-AC
EMC EN 50121-4, Railway applications –
Electromagnetic compatibility – Emission and immunity of the signalling and telecommunications apparatus
EN 55022, Information technology equipment – Radio disturbance characteristics – Limits and methods of measurement
EN 55024, Information technology equipment – Immunity characteristics Limits and methods of measurement
EN 61000-6-1, Electromagnetic compatibility – Immunity for residential environments
EN 61000-6-2, Electromagnetic compatibility – Immunity for industrial environments
EN 61000-6-4, Electromagnetic compatibility – Emission for industrial environments
FCC Part 15 Class A
Marine DNV Standard for Certification no. 2.4
FCC Part 15.105 Notice:
EN 55022 Notice:
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
DNV Standard for Certification no. 2.4
Type Temperature Humidity Vibration EMC Enclosure
RFIR-2xx-F4G-T7G-AC C B A A A/IP40
RFIR-2xx-F4G-T7G-DC D B A B A/IP40
6641-22810
5
Page 6
Safety control drawing
DC
Direction/
Position
description
1 In/out / BI_DA+
2 In/out / BI_DA–
3 In/out / BI_DB+
4 In/out / BI_DC+
5
In/out / BI_DC–
6 In/out / BI_DB–
7 In/out / BI_DD+
8 In/out / BI_DD–
Shield Functional earth
Galvanically isolated via signal transformers and capacitively isolated to GND/Functional earth through a 2kV 1000pF capacitor. See user manual for proven transient protection.
Input/output values
Per port: U = ± 1 V (4V/us) I = ± 20 mA
Data rate: 10/100/1000 Mbit/s
Direction/
Position
description
1 Out / VBUS
2 In/out / D–
3 In/out / D+
4 GND
Shield Functional earth
Output values
U
= 5 VDC max
out
I
= 500 mA max
out
Direction/
Position
description
Input/Output values
DO+ IO / Status + Uin = 60 VDC max
DO- IO / Status – Iin = 80 mA max
DI+ IO / Digital in + Uin = 60 VDC max
DI- IO / Digital in – Iin = 2.9 mA max
Direction/
Position
description
1 In / VBUS
2 In/out / D–
3 In/out / D+
4 Not connected
5 Functional earth
DC Power supply AC Power supply
Direction/ description
In / +DC1
In / +DC2
In / COM
In / COM
Input values
Uin = (16 – 60) VDC Iin = 2.0 A@16 VDC* PIn = 32 W@16 VDC*
+DC1
+DC2
COM
COM
* RFIR-227-T7G-F4G-DC ** RFIR-227-T7G-F4G-AC
Degree of protection: IP 40
Ambient temperature: –40 °C to +70 °C (DC), –40 °C to +55 °C (AC)
6
Direction/ description
In / P
In / N
In / NC
In /
Output values
U = 5 VDC max I = 100 mA max
Input values
Uin = (100–240) VAC, 50–60 Hz Iin = 360 mA@100 VAC**
6641-22810
Page 7
1
5
6
7
8
2
3
4
Safety control drawing
1
5
6
7
8
2
3
4
Position Direction* / description Input/output values
1 In/out / TD+
2 In/out / TD–
3 In/out / RD+
4 Not connected
5
Not connected
6 In/out / RD–
7 Not connected
Per port: U = ± 1 V (4V/us) I = ± 20 mA
Data rate: 10/100 Mbit/s
8 Not connected
Shield Functional earth
Galvanically isolated via signal transformers and capacitively isolated to functional earth through a 2kV 1000pF capacitor. See user manual for proven transient protection.
Position Direction* / description Input/output values
Rx In / Receive port
Tx Out / Transmit port
Max 5 dBm
Position Direction* / description Input/output values
1 In/out / BI_DA+
2 In/out / BI_DA–
3 In/out / BI_DB+
4 In/out / BI_DC+
5 In/out / BI_DC–
6 In/out / BI_DB–
7 In/out / BI_DD+
Per port: U = ± 1 V (4V/us) I = ± 20 mA
Data rate: 100/1000 Mbit/s
8 In/out / BI_DD–
Shield Functional earth
Galvanically isolated via signal transformers and capacitively isolated to functional earth through a 2kV 1000pF capacitor. See user manual for proven transient protection.
* Direction relative this unit!
6641-22810
7
Page 8
Declaration of Conformity
Org.nr/
th
Westermo Teleindustri AB
Declaration of conformity
The manufacturer
Herewith declares that the product(s)
Type of product Article number Models
Industrial Ethernet Switch for 19 inch Rack mounting
is in conformity with the following EC directive(s).
No Short name
2004/108/EC Electromagnetic Compatibility (EMC) 2011/65/EU Restriction of the use of certain hazardous substances in electrical and electronic
References of standards applied for this EC declaration of conformity.
No Title Issue
EN 50121-4 Railway applications – Electromagnetic compatibility – Emission
EN 55022 Information technology equipment – Radio disturbance
EN 55024 Information technology equipment – Immunity characteristics
EN 61000-6-1 Electromagnetic compatibility – Immunity for residential
EN 61000-6-2 Electromagnetic compatibility – Immunity for industrial
EN 61000-6-4 Electromagnetic compatibility – Emission for industrial
EN 50581 Technical documentation for the assessment of electrical and
The last two digits of the year in which the CE marking was affixed: 14
Westermo Teleindustri AB SE-640 40 Stora Sundby, Sweden
3641-4025 3641-4005 3641-4035 3641-4015
equipment (RoHS)
and immunity of the signalling and telecommunications apparatus
characteristics – Limits and methods of measurement
Limits and methods of measurement
environments
environments
environments
electronic products with respect to the restriction of hazardous substances
RFIR-227-F4G-T7G-DC RFIR-219-F4G-T7G-DC RFIR-227-F4G-T7G-AC RFIR-219-F4G-T7G-AC
2006
2010
2010
2007
2005 + C1: 2005 2007 +A1:2011 2012
Pierre Öberg Technical Manager 09
September 2014
Postadress/Postal address
S-640 40 Stora Sundby 016-428000 016-428001 52 72 79-4 5671-5550 556361-2604 Es kilstuna
Sweden Int+46 16428000 Int+46 16428001
Tel.
Telefax
Postgiro
Bankgiro Corp. identity number Registered office
8
6641-22810
Page 9
Type tests and environmental conditions
Phenomena Test Description Test levels
ESD EN 61000-4-2 Enclosure contact ± 6 kV
RF field AM modulated IEC 61000-4-3 Enclosure 20 V/m 80% AM (1 kHz), 80 – 2700 MHz Fast transient EN 61000-4-4 Signal ports ± 2 kV
Surge EN 61000-4-5 Signal ports ± 2 kV line to earth, ± 1 kV line to line
RF conducted EN 61000-4-6 Signal ports 10 V 80% AM (1 kHz), 0.15 – 80 MHz
Power frequency magnetic field
Pulse magnetic field EN 61000-4-9 Enclosure 300 A/m Radiated emission CISPR 16-2-3 Enclosure Class A
Conducted emission EN 55022 AC and DC power
Dielectric strength EN 60950 Signal port to other
Temperature EN 60068-2-1
Humidity EN 60068-2-27 Operating 5 to 95% relative humidity
Altitude Operating 2 000 m / 70 kPa Service life Operating 10 years Vibration IEC 60068-2-6 Operating 7.5 mm, 5 – 8 Hz
Shock IEC 60068-2-27 Operating 15 g, 11 ms
Enclosure UL 94 Aluminium / Zink Flammability class V-0 (all models)
EN 61000-4-8 Enclosure 300 A/m 0, 16.7, 50, 60 Hz
ANSI C63.4 (FCC part 15)
FCC part 15 AC and DC power
EN 60068-2-2
Enclosure air ± 8 kV
Power ports ± 2 kV
Power ports ± 2 kV line to earth, ± 2 kV line to line
Power ports 10 V 80% AM (1 kHz), 0.15 – 80 MHz
Enclosure Class B, 30 – 6500 MHz
ports Telecommunication ports Class B
ports
isolated ports Power port to other
isolated ports Operating -40 to +70ºC (DC models)
Storage & Transport -40 to +85ºC (all models) Maximum surface
temperature
Storage & Transport 5 to 95% relative humidity
(AC models) ± 2 kV line to earth, ± 1 kV line to line (DC models)
Class B
Class B
1.5 kVrms 50 Hz 1 min
1.5 kVrms 50 Hz 1 min
-40 to +55ºC (AC models)
135 °C (temperature class T4)
2 g, 8 – 500 Hz (19" rack mounting according to IEC 60297, DIN 41494)
(19" rack mounting according to IEC 60297, DIN 41494)
6641-22810
9
Page 10
Description
The RFIR (RedFox Industrial Rack) is a high performance layer 3 industrial Ethernet switch designed for high network traffic applications. Various port configurations are available that can be further customized with SFP transceivers. RFIR is powered by the Westermo WeOS network operating system.
RFIR is designed for 19” cabinet according to ETSI standard making it suitable for use in control room networks as well as for cabi¬nets installed along railway trackside or maritime installations. RFIR is designed to run efficiently from an AC or DC power supply, the unit is also equipped with configurable I/O fault contact that make it ideal for easy installation and monitoring in industrial applications.
RedFox Industrial Rack models
Westermo article number
3641-4005 RFIR-219-F4G-T7G-DC
3641-4015 RFIR-219-F4G-T7G-AC
3641-4025 RFIR-227-F4G-T7G-DC
3641-4035 RFIR-227-F4G-T7G-AC
Denomination Description
8 x 10/100 Mbit/s, Ethernet TX, RJ-45
7 x 10/100/1000 Mbit/s, Gigabit Ethernet TX, RJ-45
4 x 100/1000 Mbit/s, pluggable connections transceivers supported, Ethernet FX or TX SFP
DC power supply
8 x 10/100 Mbit/s, Ethernet TX, RJ-45
7 x 10/100/1000 Mbit/s, Gigabit Ethernet TX, RJ-45
4 x 100/1000 Mbit/s, pluggable connections transceivers supported, Ethernet FX or TX SFP
AC power supply
16 x 10/100 Mbit/s, Ethernet TX, RJ-45
7 x 10/100/1000 Mbit/s, Gigabit Ethernet TX, RJ-45
4 x 100/1000 Mbit/s, pluggable connections transceivers supported, Ethernet FX or TX SFP
DC power supply
16 x 10/100 Mbit/s, Ethernet TX, RJ-45
7 x 10/100/1000 Mbit/s, Gigabit Ethernet TX, RJ-45
4 x 100/1000 Mbit/s, pluggable connections transceivers supported, Ethernet FX or TX SFP
AC power supply
10
6641-22810
Page 11
480
43
469
462
18
REVISIONS
Rev
Description
Designer
Approved
Date
Housing
REVISIONS
Rev
Description
Designer
Approved
Date
Description
The RedFox Industrial Rack (RFIR) is designed for installation in 19” rack solutions according to ETSI standard with a shallow depth of 240 mm. RFIR can also be wall mounted as an installation option.
Port number RFIR-219-F4G-T7G DC or AC
Port number RFIR-227-F4G-T7G DC or AC
480
43
462 469
411
235
466
Specification
Dimension W x H x D 466 x 258 x 43 mm
18,35 x 10,16 x 1,66"
Weight 3.8 kg
Degree of protection IP40 according to EN 60529
Cooling Convection
Mounting 19" rack or wall-mounted
6641-22810
240
11
Page 12
Interface specifications
I/O USB
Console port
10/100/1000 Mbit/s
SFP slot, 100/1000 Mbit/s FX or 10/10/1000 Mbit/s TX ports
10/100 Mbit/s TX ports
TX ports
Power interface specifications
DC power
4-position Product marking Direction Description
AC power
1
1
2
3
4
3
2
4
No. 1 +DC1 Input Supply voltage input DC1
No. 2 +DC2 Input Supply voltage input DC2
No. 3 -COM Input Common
No. 4 -COM Input Common
4-position Product marking Direction Description
No. 1 P Input Power
No. 2 N Input Neutral
No. 3 NC Input No connection
No. 4 Input Funtional earth
Power
Protective earth
12
6641-22810
Page 13
Power
Rated voltage AC models 100 to 240 VAC, 50-60 Hz
DC models 20 to 48 VDC
Operating voltage AC models 90 to 264 VAC, 47-63 Hz
DC models 16 to 60 VDC
Maximum nominal current consumption
RFIR-219-F4G-T7G-DC 1120 mA @ 24 VDC
450 mA @ 48 VDC
RFIR-227-F4G-T7G-DC 1250 mA @ 24 VDC
550 mA @ 48 VDC
RFIR-219-F4G-T7G-AC 360 mA @ 100 VAC 60 Hz
200 mA @ 240 VAC 50 Hz
RFIR-227-F4G-T7G-AC 350 mA @ 110 VAC 60Hz
210 mA @ 230 VAC 50Hz
Fuse rating All models 4A(T)**
Inrush current DC models 25 mA2 @ 24 VDC
165 mA2 @ 48 VDC
AC models 75 mA2 @ 110 VAC
340 mA2 @ 230 VAC
Startup current* All models 2x nominal current
Rated frequency AC models 50/60 Hz
DC models DC
Polarity AC models Not applicable
DC models Reverse polarity protected
Redundant power input AC models No
DC models Ye s
Isolation to All other
Connection Detachable screw terminal
Connector size All models 0.2 – 2.5 mm2
(AWG 24 – 12)
Shielded cable Not required
* External supply current capability for proper start-up
** Denote time-delay fuse
6641-22810
13
Page 14
Console
Connection to console port
The console port can be used to connect to the CLI (Command Line Interface). The console connector is a micro USB cable that connects to a FTDI FT232R USB to serial converter internally. For drivers please see www.ftdichip.com and download the appropriate VCP driver.
Console
Electrical specification USB 2.0 device interface
Data rate High speed 480mbit/s
Circuit type SE LV
Maximum supply current 100 mA
Isolation to All other except USB
Galvanic connection to USB
Connection USB Micro-B connector in device mode
USB
USB
Electrical specification USB 2.0 host interface
Data rate High speed 480mbit/s
Circuit type SELV
Maximum supply current 500 mA
Isolation to All other except Console
Connection USB receptacle connector type A
Conductive housing Yes
14
6641-22810
Page 15
Network ports
Slot 1 Slot 2* Slot 3* Slot 4*
RFIR-219-F4G-T7G DC and AC
Slot 1
1 10/100/1000 Mbit/s, TX port
2 10/100/1000 Mbit/s, TX port
3 10/100/1000 Mbit/s, TX port
Slot 2
4 SFP slot
5 10/100/1000 Mbit/s, TX port
6 SFP slot
7 10/100/1000 Mbit/s, TX port
8 SFP slot
9 10/100/1000 Mbit/s, TX port
10 SFP slot
11 10/100/1000 Mbit/s, TX port
Slot 3
12 10/100 Mbit/s, TX port
13 10/100 Mbit/s, TX port
14 10/100 Mbit/s, TX port
15 10/100 Mbit/s, TX port
16 10/100 Mbit/s, TX port
17 10/100 Mbit/s, TX port
18 10/100 Mbit/s, TX port
19 10/100 Mbit/s, TX port
* Network ports at slot 2 and slot 3 differ between the different RFIR models. Slot 4 is only available in model RFIR-227-F4G­T7G DC and AC.
RFIR-227-F4G-T7G DC and AC
Slot 1
1 10/100/1000 Mbit/s, TX port
2 10/100/1000 Mbit/s, TX port
3 10/100/1000 Mbit/s, TX port
Slot 2
4 10/100 Mbit/s, TX port
5 10/100 Mbit/s, TX port
6 10/100 Mbit/s, TX port
7 10/100 Mbit/s, TX port
8 10/100 Mbit/s, TX port
9 10/100 Mbit/s, TX port
10 10/100 Mbit/s, TX port
11 10/100 Mbit/s, TX port
Slot 3
12 SFP slot
13 10/100/1000 Mbit/s, TX port
14 SFP slot
15 10/100/1000 Mbit/s, TX port
16 SFP slot
17 10/100/1000 Mbit/s, TX port
18 SFP slot
19 10/100/1000 Mbit/s, TX port
Slot 4
20 10/100 Mbit/s, TX port
21 10/100 Mbit/s, TX port
22 10/100 Mbit/s, TX port
23 10/100 Mbit/s, TX port
24 10/100 Mbit/s, TX port
25 10/100 Mbit/s, TX port
26 10/100 Mbit/s, TX port
27 10/100 Mbit/s, TX port
6641-22810
15
Page 16
1
5
6
7
8
2
3
4
10/100/1000 Mbit/s, TX ports
Ethernet TX
Electrical specification IEEE std 802.3. 2005 Edition
Data rate 10 Mbit/s, 100 Mbit/s, 1000 Mbit/s, manual or auto
Duplex Full or half, manual or auto
Circuit type TNV-1
Transmission range Up to 150 m with CAT5e cable or better
Isolation to All other
Connection RJ-45 auto MDI/MDI-X
Shielded cable Not required, except when installed in Railway applications as
Conductive housing Yes
* NOTE! Railway installation close to the rails.
To minimise the risk of interference, a shielded cable is recommended when the cable is located inside 3 m boundary to the rails and connected to this port.
The cable shield should be properly connected (360°) to an earthing point within 1 m from this port. This earthing point should have a low impedance connection to the conductive enclosure of the apparatus cabinet, or similar, where the unit is built-in. This conductive enclosure should be connected to the earthing system of an installation and may be directly connected to the functional earth. Refer also to "Safety" section.
signalling and telecommunications apparatus and located close to rails*
Position Direction* Description
1 In/Out BI_DA+
2 In/Out BI_DA–
3 In/Out BI_DB+
4 In/Out BI_DC+
5 In/Out BI_DC-
6 In/Out BI_DB-
7 In/Out BI_DD+
8 In/Out BI_DD-
Shield In/Out Connected to
Functional earth
* Direction relative this unit.
16
6641-22810
Page 17
1
5
2
6
3
7
4
8
SFP slot
Each SFP slot can hold one SFP transceiver for copper or fibre cable. Fibre transcievers distances range from 550 m (0.34 mi) to 120 km (74.6 mi). For supported transceivers, see SFP data sheet.
Position Direction* Description
Rx In Receive port
Tx Out Transmit port
* Direction relative this unit.
SFP ports
Optical/Electrical specification IEEE std 802.3 2005 Edition
Data rate 10, 100 or 1000 Mbit/s*
Duplex Full or half, manual or auto
Transmission range Depending on transceiver
Connection SFP slot holding fibre transceiver or copper transceiver
* 100 Mbit/s or 1000 Mbit/s transceiver supported.
6641-22810
17
Page 18
I/O connection
Product marking Direction Description
DI-
DI+
DO-
DO+
The Status output is a potential free, opto-isolated normally closed solid-state relay. This can be configured to monitor various alarm events within the RFIR unit, see WeOS Management Guide. An external load in series with an external voltage source is required for proper functionality. For voltage/current ratings, see Interface specification section.
Digital in – Input Digital in –
Digital in + Input Digital in +
Status – Output Alarm relay (status) contact
Status + Output Alarm relay (status) contact
The Digital in is an opto-isolated digital input which can be used to monitor external events. For voltage/current ratings, see Interface Specification section:
IO / Relay output
Connect resistance 30 W
Isolation to All other
Connection Detachable screw terminal
Connector size 0.2 – 2.5 mm2 (AWG 24 – 12)
Maximum voltage/current 60 VDC / 80 mA
IO / Digital input
Voltage levels Vih > 8V Vil < 5V
Iin = 2.9mA @60V
Isolation to All other
Connection Detachable screw terminal
Connector size 0.2 – 2.5 mm2 (AWG 24 – 12)
Maximum voltage 60 VDC
External Load
1
Status
2
3
4
V
V
+
Digital In
18
6641-22810
Page 19
LED indicators Power/CPU
LED Status Description
ON OFF Unit has no power.
GREEN All OK, no alarm condition.
RED Alarm condition, or until unit has
BLINK Location indicator ("Here I am!").
DC1 OFF Unit has no power.
GREEN Power OK on DC1.
RED +DC1 input voltage is below operating
DC2 OFF Unit has no power.
GREEN Power OK on DC2.
RED +DC2 input voltage is below operating
AC1 OFF Unit has no power
GREEN Power OK on AC1
FRNT OFF FRNT disabled.
GREEN FRNT OK.
RED FRNT Error.
BLINK Unit configured as FRNT Focal Point.
RSTP OFF RSTP disabled.
GREEN RSTP enabled.
BLINK Unit elected as RSTP/STP root switch.
USR1 Configurable, see WeOS Management Guide
TX/FX ports OFF No link.
GREEN Link established.
GREEN FLASH
YELLOW Port alarm and no link. Or if FRNT or
started up. (Alarm conditions are configurable, see ''WeOS Management Guide'').
Activated when connected to IPConfig Tool, or upon request from Web or CLI.
voltage limit
voltage limit
Data traffic indication.
RSTP mode, port is blocked.
6641-22810
19
Page 20
SFP Transceivers
ESD Protection
www.westermo.com
©
Westermo Teleindustri AB
User Guide
6100-0000
SFP
Transceivers
See SFP Transceivers data sheet for supported SFP transceivers. Note: The unit supports Westermo labelled transceivers only. See Transceiver User Guide 6100-0000 for transceiver handling instructions.
Deviations
With copper transceiver 1100-0148 the specified operating temperature on the RFI and RFIR series is 0 to 50ºC.
FRNT reconfiguration times can not be guaranteed with copper transceivers.
20
6641-22810
Page 21
Mounting
This unit can either be rackmounted or wallmounted, see figures below.
Rackmounting
_
<
The unit can be mounted in all directions
+85°C (+185°F)
inside a 19" apparatus cabinet. Use M6x25 or 1/4"x1" screws.
Wallmounting
The unit can also be wallmounted in all directions. Use maximum Ø6,4 mm or
_
<
+85°C (+185°F)
1/4"screws.
Cooling
For mounting in 19" apparatus cabinet without forced ventilation, a minimal spacing of 1U according to IEC 60297 or 45 mm (1.75") above/below is recommended. With forced ventilation, no minimal spacing is required as long as the temperature of the rear cooling plates does not exceed +85ºC (+185ºF).
For wallmounting in an area without forced ventilation, a minimum spacing of 45 mm (1.75") above/below and 10 mm (0.4") left/right is recommended. For areas with forced ventilation, no minimal spacing is required as long as the temperature of the rear cooling plates does not exceed +85ºC (+185ºF).
Earth connection
For correct function, the ground connection on the unit needs to be properly connected to a solid ground. See the figure below.
Protective earth
6641-22810
21
Page 22
Getting Started
This product runs Westermo Operating System (WeOS) which provides several management tools that can be used for configuration of the unit.
• WeConfig
WeConfig is a Network configuration management tool (NCM) made for commissioning and maintenance of components in a network.
• Web
Configuration of the unit using the web browser.
• CLI Configuration of the unit via the Command Line Interface.
If the computer is located in the same subnet as the switch you can easily use a web browser to configure the unit. Within the web you can configure most of the available functions.
For advanced network settings and more diagnostic information, please use the CLI. Detailed documentation is available in the chapter The Command Line Management Tool in the WeOS management guide.
Factory default IP address: 192.168.2.200 (and DHCP client) Netmask: 255.255.255.0 Gateway: Disabled
Note! If you are not sure about the subnet – consult your network administrator.
Configuration
Configure the unit via Web browser
The unit can easily be configured via a Web browser. Open the link http://192.168.2.200 in your web browser, and you will be prompted with a Login screen, where the default settings for Username and Password are:
Username: admin Password: westermo
Once you have logged in, you can use the extensive integrated help function describing all configuration options. Two common task when configuring a new switch is to assign appropriate IP settings, and to change the password of the admin account. The password can be up to 64 characters long, and should consist of printable ASCII characters (ASCII 33-126); 'Space' is not a valid password character.
22
6641-22810
Page 23
Referring documents
All needed documentation can be downloaded from the product webpage. Related software tools are available in the folder software tools under technical support on the Westermo website.
Type Description Document number
Management Guide Westermo OS management guide
6101-3201
Cable factory reset on RedFox Industrial Rack
It is possible to set the unit to factory default settings by using a standard (straight) Ethernet RJ-45 cable.
1. Power off the switch and disconnect all Ethernet cables (including copper and fibre).
2. Connect an Ethernet cable between Ethernet port 1 and Ethernet port 2. The ports need to be connected directly by an Ethernet cable, i.e., not via a hub or switch. Use a straight cable - not a cross-over cables - when connecting the ports.
3. Power on the unit.
4. Wait for the unit to start up. Control that the ON LED is flashing red. The ON LED flashing indicates that the unit is now ready to be reset to factory default. You now have the choice to go ahead with the factory reset, or to skip factory reset and boot as normal.
• Go ahead with factory reset: Acknowledge that you wish to conduct the factory reset by unplugging the Ethernet cable. The ON LED will stop flashing. This initiates the factory reset process, and the unit will restart with factory default settings. When the switch has booted up, the ON LED will show a green light, and is now ready to use.
• Note! Do not power off the unit while the factory reset process is in progress. Skip the factory reset: To skip the factory reset process, just wait for approximately 30 seconds (after the ON LED starts flashing RED) without unplugging the Ethernet cable. The switch will conduct a normal boot with the existing settings.
6641-22810
23
Page 24
Westermo • SE-640 40 Stora Sundby, Sweden
Tel +46 16 42 80 00 Fax +46 16 42 80 01
Sales Units
Westermo Data Communications
E-mail: info@westermo.com
www.westermo.com
China sales.cn@westermo.com www.cn.westermo.com
France infos@westermo.fr www.westermo.fr
Germany info@westermo.de www.westermo.de
For complete contact information, please visit our website at www.westermo.com/contact or scan the QR code
REV. D 6641-22810 2015-06 Westermo Teleindustri AB, Sweden – A Beijer Electronics Group Company